• 제목/요약/키워드: ionic concentration

검색결과 731건 처리시간 0.024초

제주시 대기부유부진 중 수용성 이온성분의 입경별 분포특성 (Size Distribution of Water-Soluble Ionic Components in the Atmospheric Aerosols Collected in Jeju City, Korea)

  • 허철구;송정화;이기호
    • 한국환경과학회지
    • /
    • 제13권12호
    • /
    • pp.1067-1078
    • /
    • 2004
  • Atmospheric particulate matters were collected by 8-stage non viable cascade impactor from October 2002 to August at Jeju City. Eight water-soluble ionic components $(Na^+,\;NH_{4}_{+},\;K^+,\;Ca{2+},\;Mg^{2+},\;CI^-,\;NO_{3}^-\;and\;SO_{4}^{2-})$ were analyzed by Ion Chromatography. The concentration of particulate matters and eight water-soluble ionic components were determined to investigate their size distributions. Particulate matters exhibited a tri-modal distribution with peak value around $0.9,\;4.0{\mu}m\;and\;9.5{\mu}m.$ In summer, the last peak value was lower than other season values likely due to particulate matter scavenged by rain water. Four ionic components $(Na^+,\;Ca^{2+},\;Mg^{2+}\;and\;CI^-)$ exhibited a bi-modal distribution in the coarse mode whereas three ionic components $(NH_{4}^+,\;K^+\;and\;SO_{4}^{2-})$ in the fine mode, with maximum peak value around $0.9{\mu}m.\;NO_{3}^-$ was found in both the coarse and the fine mode. The enrichment factor (E.F.) of each ionic components was calculated. Based upon E.F., it is considered that $Na^+,\;CI^-,\;and\;K^+$ in coarse paricle mode were delivered form oceanic source, but other components might have other source origins.

염산용액에서 Cyanex 272 및 혼합용매와 이온성 액체에 의한 Tb(III)의 용매추출 (Solvent Extraction of Tb(III) from Hydrochloric Acid Solution with Cyanex 272, Its Mixture and Ionic Liquid)

  • 오창근;이만승
    • 대한금속재료학회지
    • /
    • 제56권12호
    • /
    • pp.870-877
    • /
    • 2018
  • Cyanex 272 shows the highest separation factor for the rare earth elements from hydrochloric acid solution among the organophosporus acidic extractants, D2EHPA and PC 88A. Solvent extraction of Tb(III) from weak hydrochloric acid solution with an initial pH 3 to 6 was compared with Cyanex 272, its mixture with Alamine 336, and ionic liquid with Aliquat 336. The solvent extraction reaction of Tb(III) using Cyanex 272 was the same as that of light rare earth elements. Synergism was observed for the extraction of Tb(III) by the mixture with Alamine 336 when the initial concentration ratio of Cyanex 272 to Alamine 336 was higher than 5. Use of the ionic liquid led to a great increase in the extraction percentage of Tb(III) from the same initial extraction conditions. While the equilibrium pH of the mixture was always lower than the initial pH, under some conditions extraction with the ionic liquid resulted in a higher equilibrium pH than the initial pH. The loading capacity of the mixture and the ionic liquid was the same and 2.6 times larger than that using Cyanex 272 alone. Ionic liquid was recommended as a suitable extractant for the extraction of Tb(III) from hydrochloric acid solution based on the ease of handling and higher extraction percentage.

친수 및 소수처리 PET직물의 고형오구의 세척성 (Detergency of Particulate Soil of PET Fabric Finished with Hydrophilic and Hydrophobic Chemicals)

  • 강인숙
    • 한국의류학회지
    • /
    • 제36권11호
    • /
    • pp.1237-1245
    • /
    • 2012
  • The effect of hydrophilicity and hydrophobicity of PET fabric on the detergency of particulate soil were investigated as functions of the concentration of hydrophilic and hydrophobic chemicals, surfactant concentration, ionic strength, adhesion and removal time, and pH. The detergency of the particulate soil was determined by the adhesion of particles to and their removal from fabric, the PET fabric and ${\alpha}-Fe_2O_3$ were used as textile materials and for the model of particulate soil, respectively. The hydrophilic and hydrophobic finish for PET fabric was treated with a polyester, silicone and fluorine organic compound of resin respectively. The adhesion of particulate soil to fabric treated with hydrophobic chemicals were slightly higher but its removal from fabric treated with hydrophobic chemicals was largely higher than fabric treated with a hydrophilic chemical regardless of solution conditions such as the concentration of hydrophilic and hydrophobic chemicals, surfactant concentration, ionic strength, adhesion and removal time, and pH. Therefore, hydrophobic treatment for fabric had a more positive effect than the hydrophilic treatment on the detergency of particulate soil.

Molecular Dynamics Simulation Study for Ionic Strength Dependence of RNA-host factor Interaction in Staphylococcus aureus Hfq

  • Lazar, Prettina;Lee, Yun-O;Kim, Song-Mi;Chandrasekaran, Meganathan;Lee, Keun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권6호
    • /
    • pp.1519-1526
    • /
    • 2010
  • The behavior of peptide or protein solutes in saline aqueous solution is a fundamental topic in physical chemistry. Addition of ions can strongly alter the thermodynamic and physical properties of peptide molecules in solution. In order to study the effects of added ionic salts on protein conformation and dynamics, we have used the molecular dynamics (MD) simulations to investigate the behavior of Staphylococcus aureus Hfq protein under two different ionic concentrations: 0.1 M NaCl and 1.0 M NaCl in presence and absence of RNA (a hepta-oligoribonucleotide AU5G). Hfq, a global regulator of gene expression is highly conserved and abundant RNA-binding protein. It is already reported that in vivo the increase of ionic strength results in a drastic reduction of Hfq affinity for $Q{\beta}$ RNA and reduces the tendency of aggregation of Escherichia coli host factor hexamers. Our results revealed the crucial role of 0.1 M NaCl Hfq system on the bases with strong hydrogen bonding interactions and by stabilizing the aromatic stacking of Tyr42 residue of the adjacent subunits/monomers with the adenine and uridine nucleobases. An increase in RNA pore diameter and weakened compactness of the Hfq-RNA complex was clearly observed in 1.0 M NaCl Hfq system with bound RNA. Aggregation of monomers in Hfq and the interaction of Hfq with RNA are greatly affected due to the presence of high ionic strength. Higher the ionic concentration, weaker is the aggregation and interaction. Our results were compatible with the experimental data and this is the first theoretical report for the experimental study done in 1980 by Uhlenbeck group for the present system.

이미다졸계 이온성액체와 염을 포함한 수상이성분계를 이용한 숙신산의 추출 평형 (Extraction Equilibria of Succinic Acid by Using Aqueous Two Phases System Containing Imidazolium Ionic Liquids and Salts)

  • 이용화;강정원;홍연기;김기섭
    • 청정기술
    • /
    • 제20권4호
    • /
    • pp.349-353
    • /
    • 2014
  • 숙신산은 의약품, 식품 첨가물, 청정용매와 같은 종래의 응용 이외에도 생분해성 고분자의 중요한 전구물질로 주목 받고 있다. 그러나 최근 화석 연료의 높은 가격과 화석 원료 유래 제품의 전주기에 걸친 온실가스 배출로 인해 재생 가능한 바이오매스에 의한 숙신산의 생물학적 생산에 대한 관심이 높아지고 있다. 본 연구에서는 숙신산의 선택적인 추출과 농축을 동시에 수행할 수 있는 공정으로서 이미다졸계 이온성 액체/$K_2HPO_4$에 의한 수상이성분계를 적용하였다. 실험 결과 숙신산에 존재하는 $K_2HPO_4$ 수용액에 적정량의 이미다졸계 이온성 액체가 첨가됨에 따라 안정한 수상이성분계가 형성됨을 확인할 수 있었으며 수상이성분계 형성 능력은 [HMIm][Br]${\fallingdotseq}$[OMIm][Br]>[BMIm][Br]>[EMImBr]의 순서로 나타났다. 숙신산의 최대 추출 효율은 약 90%였으며 이온성 액체에서 양이온 사슬길이가 증가할수록 상부상으로 동반 추출되는 물의 양이 줄어들어 숙신산의 선택적 농축효과가 크게 나타났다. 따라서 본 연구에서 사용된 이미다졸계 이온성 액체와 $K_2HPO_4$으로 구성된 수상이성분계는 숙신산의 선택적 추출과 농축에 효과적임을 알 수 있었다.

The joint effect of different concentration of Cd2+ and ionic liquid on the growth of wheat seedlings

  • Chen, Zhonglin;Zhou, Qian;Leng, Feng;Dai, Bing;Zhao, Xueyang;Zhang, Weichen;Liu, Neng;Guan, Wei;Liu, Kui
    • Environmental Engineering Research
    • /
    • 제22권3호
    • /
    • pp.281-287
    • /
    • 2017
  • The joint effect of different concentrations (0.05-0.375 mmol/L) of $Cd^{2+}$ and various concentrations (50-400 mg/L) of [$C_3mim$][OAc] on the growth and physiology of wheat seedlings were investigated. The toxicity of $Cd^{2+}$ could be significantly reduced by lower concentrations (50-200 mg/L) of [$C_3mim$][OAc]. With higher concentration (${\geq}300mg/L$) of [$C_3mim$][OAc], the reduction became less, and compared to $Cd^{2+}$ stress only, the toxicity of 400 mg/L [$C_3mim$][OAc] increased. As for different $Cd^{2+}$ concentrations, the optimal reduction depends on the balance between the exact concentration of $Cd^{2+}$ and [$C_3mim$][OAc]: With low $Cd^{2+}$ concentration (0.05-0.250 mmol/L) requiring 50 mg/L [$C_3mim$][OAc], it could reach a dynamic equilibrium, while high $Cd^{2+}$ concentration (0.375 mmol/L) requiring 100 mg/L [$C_3mim$][OAc]. The growth and physiological indexes of wheat seedlings show a decrease in toxicity compared to the Cd alone treatment, when the dynamic equilibrium is reached. The concentration of $Cd^{2+}$ in leaf tissues showed that low concentration (50-200 mg/L) of [$C_3mim$][OAc] can reduce the toxicity of $Cd^{2+}$ (0.05-0.375 mmol/L) by decreasing the level of $Cd^{2+}$ concentration in the tissues, whereas the higher concentration (${\geq}300mg/L$) of [$C_3mim$][OAc] can increase the concentration of $Cd^{2+}$.

Hypsochromic Shifts in Retinochrome Absorption Spectra in the Presence of Nitrate

  • Takemori, Nobuaki;Mizukami, Taku;Tsujimoto, Kazuo
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.264-266
    • /
    • 2002
  • The absorption wavelength of the protonated retinal Schiff base can be controlled by the surrounding environment. An external anion is related to fine adjustment of the absorption wavelength. The addition of anion to retinochrome solution caused blue shift in spectra. The increase of the shift was dependent on the ion concentration. The large shift value was obtained as 20 nm at the saturated concentration of nitrate. The shift intensity for the nitrate addition exceeded that of chloride. Seemingly, it depends on the ionic strength or lyotropic character of the anion. However, neither of sulphate nor gluconate ion showed remarkable blue shift. These phenomena were accounted for with (1) delocalization of the positive charge in the conjugated polyene system, (2) ionic bonding strength between the counter ion (glutamate) and the proton, and/or (3) interaction of the added anion with the proton on Schiff base.

  • PDF

[(ZrO2)$_{1-x}$(CeO2)$_x$$_{0.92}$(Y$_2$O$_3$)$_{0.08}$ 고용체의 전기전도도 (Electrical Conductivities of [(ZrO2)$_{1-x}$(CeO2)$_x$]$_{0.92}$(Y$_2$O$_3$)$_{0.08}$ Solid Solution)

  • 이창호;최경만
    • 한국세라믹학회지
    • /
    • 제35권12호
    • /
    • pp.1323-1328
    • /
    • 1998
  • The electrical conductivities of the yttria (8mol%) stabilizedzirconia-ceria solid solutions were measured as a function of oxygen partial between 80$0^{\circ}C$ and 100$0^{\circ}C$ using 4-probe d.c. method Under pure oxygen atmosphere the oxygen ionic conductivity of CeO2-ZrO2 decreased with the concentration of CeO2 Under reducing condition electronic conduction due to the redox equilibrium of Ce ion was observed. Total ionic and electronic conductivities fitted by a defect model enabled to determine the electronic transference number(tei) which increased with the concentration of CeO2 and with the degree of reduction.

  • PDF

해수중의 물질 분리 및 분석을 위한 Fl-FFF의 안정화 기법 (Stabilization Methods to Separate and Analyze Materials in Seawaters using Fl-FFF)

  • 최수훈;이상엽;홍승관;문지희
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.288-294
    • /
    • 2009
  • Flow field-flow fractionation (Fl-FFF) device has been widely used to verify the size and molecular weight of various colloids and organics. The Fl-FFF, however, generally uses carrier solutions with only low to moderate ionic strengths to exclude the high affinity of materials to the membrane under high ionic strength conditions. Thus, materials existing in seawaters have not been accurately analysed based on the hydrodynamic size and molecular weight using current Fl-FFF techniques. The highest ionic strength tested was up to 0.1 M, while seawater ionic strength is about 0.6 M. The aim of this study is to accurately measure the hydrodynamic size of particles under carrier solutions close to seawater conditions with the Fl-FFF. By employing various operating conditions during the Fl-FFF analyses, it was demonstrated that the flow conditions, the concentration of surfactants, and stabilization times were key factors in acquiring compatible data. Results have shown that the cross flow was more influential factor than the channel flow. The concentration of the surfactant was to be at least 0.05% and the minimum 15 hr of stabilization was needed for accurate and reproducible data acquisition under seawater condition.

기상현상에 따른 제주지역 TSP의 이온조성 변화 특성 (Variation Characteristics of TSP Ionic Compositions by Meteorological Phenomena in Jeju Island)

  • 고희정;김원형;이승훈;부준오;강창희;허철구
    • 한국대기환경학회지
    • /
    • 제27권6호
    • /
    • pp.723-733
    • /
    • 2011
  • The ionic compositions were analyzed from the TSP samples collected at Gosan site in Jeju Island between 2000 and 2008, in order to examine the characteristics of atmospheric aerosols in accordance with the meteorological conditions. For the Asian Dust influence on the ionic compositions, the concentration ratios of $NH_4{^+}$, nss-${SO_4}^{2-}$, $NO_3{^-}$, and $K^+$ were about 1.2~2.3 during Asian Dust over Non-Asian Dust periods, noticeably that of nss-$Ca^{2+}$ was 6.8. Meanwhile the concentrations of nss-${SO_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$ have increased as 1.8~4.4 times during the haze event periods, and 1.0~1.6 times during the fog and mist events. The ion balance has resulted that the anionic concentrations are relatively lower than the cationic concentrations, and the discrepancy appears more decidedly as a strong Asian Dust effect. The ammonium ion balance has shown that it exists as a mixture of $NH_4HSO_4$ and $(NH_4)_2SO_4$. The concentration ratios of nss-${SO_4}^{2-}/NO_3{^-}$ for Asian Dust, haze, fog-mist, and non-event periods were respectively 1.8, 5.9, 4.6, and 2.9, which were higher values compared to those in urban areas of China as well as other domestic regions. Especially, the high ratios of sulfur oxides could be presumed by the fact that the longrange transport of air pollutants from Asia continent might affect the atmospheric aerosols of Jeju Island.