• Title/Summary/Keyword: ion filter

Search Result 191, Processing Time 0.031 seconds

A Study on the Formation of Nitrate in the Atmosphere (환경 대기중 Nitrate의 생성에 관한 연구)

  • 천만영;강공언;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.68-73
    • /
    • 1992
  • A study on the formation of particulate nitrate$(NO_3^-)$ and gaseous nitrate$(HNO_3)$ in the atmosphere was carried out in Seoul from Oct 8 to 11 1991. To collect $NO_3^-$ and $HNO_3$ in the ambient air, dual filter pack sampler (47mm$\phi$) was used. In the dual filter pack sampler, the first filter was Teflon filter (poresize 1$\mum$) for collection of $NO_3^-$ and the second filter was Nylon filter (poresize 0.45 $\mum$) for $HNO_3$. Particulate nitrate$(NO_3^-)$ and Sulfate ions were analysed by Ion chromatography. $HNO_3$ concentration was higher in the day time $(9.93\mug/m^3)$ than the night time$(3.50\mug/m^3)$, and Particulate nitrate$(NO_3^-)$ concentration was higher in the night time and early morning$(6.21\mug/m^3)$ than the day time$(4.31\mug/m^3)$. The conversion rate of $NO_x$ to total nitrate$(NO_3^-, HNO_3)$ was 7.57%/hr in the day time and 4.79%/hr in the night time, and total average conversion rate was 5.60%/hr.

  • PDF

The Adsorption Effect of Filter Paper on the Results of Trace Analysis (거름종이에 의한 흡착이 미량 분석 결과에 미치는 영향)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.82-84
    • /
    • 2004
  • The quantitative trace analysis of ions could be deteriorated by filter papers because of the effect of adsorption. Generally the adsorption of anions on filter paper did not occurred. Instead, $Cl^-$ and $NO{_3}^-$ ions were extracted from the filter papers. However, most metal ions were adsorbed on the filter papers by the formation of hydroxide in neutral solution. The adsorption of metal ions except $Ag^+$ ion could be avoided depend on the acid concentrations.

Design of High voltage nano pulse generator circuit for ion shutter of particle accelerator (입자가속기 Ion gate 구동을 위한 고전압 nano-pulse 발생기 회로 설계)

  • Oh, Hyun Jun;Jeong, Ku Young;Song, Kwan Seok;Roh, Chung Wook
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.248-250
    • /
    • 2019
  • 입자가속기는 물질의 미세 구조를 밝히기 위해 기본 입자를 가속, 충돌시키는 장치로 최근 암치료 등 의학적 용도로도 이용되고 있다. 그러나 고속으로 고압을 인가시켜야 하는 장치인 만큼 기존에 명확히 설립된 회로가 없다. 이에 본 논문에서는 Ion gate를 등가회로로 구성하여 Fast Switch 장치의 기본 회로를 제안 및 분석, 실험하였다. 또한 기본 회로에서 발생하는 문제들을 개선하고자 RC Input filter와 기타 파라미터들의 설계와 Fast switch와 Ion gate를 잇는 wire 내의 기생성분을 고찰하였고 Ion gate 구동을 위해 기준이 되는 명확한 Fast switch 회로를 제안한다.

  • PDF

Development of Individual Trespassing Detector for Building (개체 독립형 건축물 침입감지기 개발)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.400-403
    • /
    • 2008
  • In this work, an individual trespassing detector using a PIR sensor to detect infrared rays only between the range of $9.4{\sim}10.4{\mu}m$ radiated from the body is proposed. This detector using FIR sensor detects not insect or object but human body, It doesn't restrict the inhabitant's behavior because the filter of pm sensor is designed to have face angle and the detector only detects the window area. The existing wide angle filter, RIR sensor, detects $30^{\circ}$ angle while the face angle filter sensor on this paper detects $11^{\circ}$ angle with 3cm of face angle filter from 2m of detecting distance. In case of interruption of electric power, 250mAh of lithium-ion battery has worked for 10 hours consuming 22mA in normal state. Meanwhile, in case of interruption of electric power, 250mAh of battery has worked for 4 hours consuming 60mA in trespassing detecting state. Projector, receptor, controller and alarm are put on one PCB in order to make it convenient to install without any special installation skill.

The Estimation of the SOC and Capacity for the Lithium-Ion Battery using Kalman Filter

  • Lee, Seong-Jun;Kim, Jong-Hoon;Lee, Jae-Moon;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.60-62
    • /
    • 2007
  • The open circuit voltage (OCV) is widely used to estimate the state of charge (SOC) in many estimation algorithms. However, the relationship between the OCV and SOC can not be exactly same for all batteries. Because the conventional OCV-SOC differs between batteries, there is a problem that the relationship of the OCV-SOC should be measured to accurately estimate the SOC. Therefore, the conventional OCV-SOC is modified to a new relationship in this paper. Thus, problems resulting from the defects of the extended Kalman filter (EKF) can be avoided by preventing the relationship from varying. In this paper, SOC and capacity of the lithium-ion battery are estimated using the dual EKF with the proposed method.

  • PDF

Study on Electro-Optical Specific of Polyimide and Organic Overcoat (PI와 유기 절연막 과의 전기광학 특성 비교에 관한 연구)

  • Kim, Byoung-Yong;Kim, Jong-Hwan;Han, Jeong-Min;Kim, Young-Hwan;Kang, Dong-Hoon;Kim, Jong-Yeon;Ok, Chul-Ho;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.376-376
    • /
    • 2007
  • In Liquid Crystal Display (LCD) manufacturing, the organic over coat materials over coat materials for insulation layer of color filter with acryl ate was widely used. Therefore, we approach that the organic overcoat material can use to insulation layer for color filter and liquid crystal (LC) alignment layer in this research. The LC aligning capabilities was successful stuided for the first time. The organic overcoat layer and polymer layer was coated by spin-coating. In order to characterize the LC alignment, electric optic and residual DC and atomic force microscopy (AFM) image was used. The good LCD aligning capabilities treated on the organic overcoat thin film surfaces with ion beam exposure of $45^{\circ}$ above ion beam energy density of 1200 eV can be achieved. Also the good LCD alignment capabilities treated polymer on surfaces with ion beam exposure of $45^{\circ}$ above ion beam energy density of 1800 eV can be achieved. Comparing electro-optical characteristics between the Polyimide (PI) and the overcoat, the resultant transmittance of the overcoat considerably matched that of the PI and the residual DC also exhibited similar features with the PI.

  • PDF

Ion Pair Extraction of Aliphatic Amines and Quaternary Ammonium Salts by Picric Acid (Picric Acid에 의한 지방족 아민류와 4급 암모늄 염류의 이온쌍 추출)

  • 김박광;이종숙;장성기;나운용;옥치환
    • YAKHAK HOEJI
    • /
    • v.35 no.3
    • /
    • pp.182-189
    • /
    • 1991
  • Systematic study on the extraction of ion pair by the use of picric acid (PCA) as an ion pair forming reagent to the aliphatic amines has not be done by spectrophotometric method. The extraction of ion pair by the use of PCA and 23 kinds of the aliphatic amines was examined. The procedure is as follows; Elving's buffer solution (pH 1.3~10, ionic strength 0.5) each amine solution, and PCA solution were taken into a test tube. The mixture was shaken mechanically with chlorform. The organic phase was filtered through a filter paper to remove water droplets. The absorbance was examined at $\lambda_{max}$ against a reagent blank. Primary and secondary whose carbon number were more than 7 or 6, respectively, are extractable as ion pairs with PCA, while tertiary amines and quaternary ammonium salts are also extractable without the correlation of carbon number. It was considered that the ion pair extraction of primary and secondary amines was affected by the number of carbon of amines, but its extraction of tertiary amines or quaternary ammonium salts was affected by kind of aliphatic amines rather than pKa values or carbon number of amines.

  • PDF

Application of brass scrubber filter with copper hydroxide nanocomposite structure for phosphate removal

  • Hong, Ki-Ho;Yoo, In-Sang;Kim, Sae-Hoon;Chang, Duk;Sunwoo, Young;Kim, Dae-Gun
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.199-204
    • /
    • 2015
  • In this study, a novel phosphorus removal filter made of brass scrubber with higher porosity of over 96% was fabricated and evaluated. The brass scrubber was surface-modified to form copper hydroxide on the surface of the brass, which could be a phosphate removal filter for advanced wastewater treatment because the phosphates could be removed by the ion exchange with hydroxyl ions of copper hydroxide. The evaluation of phosphate removal was performed under the conditions of the batch type in wastewater and continuous type through filters. Filter recycling was also evaluated with retreatment of the surface modification process. The phosphate was rapidly removed within a very shorter contact time by the surface-modified brass scrubber filter, and the phosphate mass of 1.57 mg was removed per gram of the filter. The possibility of this surface-modified brass scrubber filter for phosphorus removal was shown without undesirable sludge production of existing chemical phosphorus removal techniques, and we feel that it would be very meaningful as a new wastewater treatment.

Optimal Immobilization of Penicillinase for Ion-selective Electrode

  • Hur, Moon-Hye;Kang, Hee-Jin;Min, Hye-Young;Lee, Ji-Yeun;Lee, Ki-Hyun;Ahn, Moon-Kyu
    • Archives of Pharmacal Research
    • /
    • v.20 no.1
    • /
    • pp.68-71
    • /
    • 1997
  • Penicillin sensor was prepared by immobilizing penicillinase (Pcase) on $H^{+}$-selective carboxylated poly (vinyl chloride) (PVC-COOH) membrane or cellulose filter membrane. The immobilization techniques are as follows. Pcase was immobilized with GTH on $H^{+}$-selective PVC-COOH membrane or some amount of BSA was dropped on that membrane. Another method to make immobilization is to mix type I Pcase with GTH and drop on a cellulose filter membrane. According to immobilization techniques, there were some differences in response properties of enzyme electrodes, however, all electrodes responded to Pcase-resistant penicillin derivatives. Pcase immobilized on cellulose filter membrane with $H^{+}$-selective PVC membrane eletrode was more stable and more sensitive to penicillinase-resistant penicillin derivatives than any other immobilization techniques.

  • PDF

Study for Reduction Effect of Pool Top Radiation in Research Reactor by Using Ion Exchanger of Hot Water Layer (고온층계통의 이온교환기에 의한 연구로 수조 상부 방사선의 저감효과에 대한 연구)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.40-47
    • /
    • 1999
  • A hot water layer (HWL hereinafter) was installed at the depth of 1.2 m from the pool surface to reduce the radiation level at the pool top. After the HWL system was improved by the replacement of the filter with the Ion Exchanger to capture the Na-24, to purify the pool water of HWL and finally to reduce the radiation at the pool top. It was confirmed by the performance test of the pump and the measurement of the pressure difference through the Ion Exchanger and the strainer, that the flow characteristics of HWL system was not adversely affected after the system modification. Also the flow analysis using the pressure loss coefficients of the Ion Exchanger and strainer, calculated by the Darcy formula, could predict the flow variations by pressure changes within $10\%$ error in comparison with the field test results. It was also confirmed that HWL was maintained with the depth of 1.2 m from the pool surface because each electric water heater was electrically and thermodynamically maintained at 30 kW and the temperature of HWL was maintained with $5^{\circ}C$ higher temperature than that of pool water. Finally, it was confirmed that the pool top radiation was saturated and stabilized below 10000 nG/hr within 24 hours as the ion exchanger captured the main nucleus, Na-24 and purified the pool water of HWL.

  • PDF