• Title/Summary/Keyword: ion detection

Search Result 665, Processing Time 0.023 seconds

Development of analytical method for determination of spinetoram residues in livestock using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 Spinetoram 공정시험법 개발 및 검증)

  • Ko, Ah-Young;Kim, Heejung;Do, Jung Ah;Jang, Jin;Lee, Eun Hyang;Ju, Yun Ji;Kim, Ji Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.94-103
    • /
    • 2016
  • An analytical method was developed to determine the amount of spinetoram (spinetoram J and spinetoram L) in livestock samples. The spinetoram was extracted with acetonitrile and purified through a primary secondary amine (PSA) sorbent. The spinetoram residues were then quantified and confirmed using a liquid chromatography–tandem mass spectrometer (LC-MS/MS) in the positive ion mode using multiple reactions monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005-0.5 mg/kg) into a blank extract with r2 > 0.994. The limits of detection and quantification were 0.002 and 0.01 mg/kg, respectively. The recovery results of spinetram ranged between 81.9-106.4% at different concentration levels (LOQ, 10LOQ, 50LOQ, n=5) with relative standard deviations (RSDs) less than 10%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL40, 2003). An interlaboratory study was conducted to validate the method. The proposed analytical method proved to be accurate, effective, and sensitive for spinetoram determination. The method will be used as an official analytical method in Korea.

Relationships between Fatty Acids and Tocopherols of Conventional and Genetically Modified Peanut Cultivars Grown in the United States (미국산 전통품종과 유전자 재조합 땅콩품종의 지방산과 토코페롤의 상관관계)

  • Shin, Eui-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1618-1628
    • /
    • 2013
  • Relationships between fatty acids and tocopherols in conventional and genetically modified peanut cultivars were studied by gas chromatography with flame ion detector and high performance liquid chromatography with fluorescence detection. Eight fatty acids and four tocopherol isomers in the sample set were identified and quantified. Oleic acid and linoleic acid are major fatty acids and the ratio of oleic and linoleic acids ranged from 1.11 to 16.26. Tocopherols contents were 6.76 to 12.24 for ${\alpha}$-tocopherol (T), 0.08 to 0.39 for ${\beta}$-T, 5.28 to 15.02 for ${\gamma}$-T, and 0.17 to 1.17 mg/100 g for ${\delta}$-T. Correlation coefficient (r) for fatty acids and tocopherols indicated a strong inverse relationship between oleic & linoleic acids (r=-0.97, P<0.05) and positive relationships between palmitic & linoleic acids (r=0.95, P<0.05) and ${\gamma}$-T & ${\delta}$-T (r=0.83, P<0.05). Principal component analysis (PCA) of fatty acids and tocopherols gave four significant principal components (PCs, with eigenvalues>1), which together account for 85.49% of the total variance in the data set with PC1 and PC2 contributing 45.27% and 21.33% of the total variability, respectively. Eigen analysis of the correlation matrix loadings of the four significant PCs revealed that PC1 was mainly contributed by palmitic, oleic, linoleic, and gondoic acids, while PC2 was by behenic acid, ${\beta}$-T, and ${\gamma}$-T. The score plot generated by PC1-PC2 identified sample clusters in the two spatial planes based on the oleic and linoleic acids. The score plot PC3-PC4 didn't separate sample groups.

Development and Validation of an Analytical Method for Determination of Fungicide Tridemorph in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 tridemorph의 시험법 개발 및 검증)

  • Pak, Won-Min;Do, Jung-Ah;Lim, Seung-Hee;Park, Shin-Min;Yoon, Ji-Hye;Lee, Dong-seouk;Chang, Moon-Ik
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.290-297
    • /
    • 2017
  • The purpose of this study was developed for the determination of tridemorph in agricultural commodities samples. Tridemorph residues in samples were extracted with acetonitrile, partitioned with saline water, and then purified using and aminopropyl ($NH_2$) SPE catridge. The purified samples were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~2.5 ng) into a blank extract with $r^2$ > 0.999. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. The average recovery ranged between 75.9% and 103.7% at different concentration levels (LOQ, 10 LOQ, 50 LOQ, n = 5) with relative standard deviations (RSDs) less than 9.0%. An interlaboratory study was conducted to validate the method by Korea Advanced Food Research Institute. The average recovery ranged between 87.0% and 109.2% at different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$, n = 5) with relative standard deviations (RSDs) less than 8.0%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL40, 2003) and Food Safety Evaluation Department guidelines (2016). The results prove that the developed analytical methods is accurate, effective and sensitive for tridemorph determination.

Simultaneous Determination of Penicillin Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 페니실린계 항생제 8종의 동시분석 및 적용성 검증)

  • Kim, Myeong-Ae;Yoon, Su-Jin;Kim, MeeKyung;Cho, Yoon-Jae;Choi, Sun-Ju;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2014
  • The objective of this study was to develop a simultaneous method of 8 penicillin antibiotics including amoxicillin, ampicillin, cloxacillin, dicloxacillin, nafcillin, oxacillin, penicillin G and penicillin V in meat using LC-MS/MS. The procedure involves solid phase extraction with HLB cartridge and subsequent analysis by LC-MS/MS. To optimize MS analytical condition of 8 compounds, each parameter was established by multiple reaction monitoring in positive ion mode. The chromatographic separation was achieved on a $C_{18}$ column with a mobile phase of 0.05% formic acid and 0.05% formic acid in acetonitrile at a flow rate of 0.2 mL/min for 20 min with a gradient elution. The developed method was validated for specificity, linearity, accuracy and precision in beef, pork and chicken. The recoveries were 71.0~106%, and relative standard deviations (RSD) were 4.0~11.2%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.003~0.008 mg/kg and 0.01~0.03 mg/kg, respectively, that are below maximum residue limit (MRL) of the penicillins. This study also performed survey of residual penicillin antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Penicillins were not found in all the samples except a sample of pork which contained cloxacillin (concentration of 0.08 mg/kg) below the MRL (0.3 mg/kg).

Simultaneous Determination of Aminoglycoside Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 아미노글리코사이드계 항생제 9종의 동시분석 및 적용성 검증)

  • Cho, Yoon-Jae;Choi, Sun-Ju;Kim, Myeong-Ae;Kim, MeeKyung;Yoon, Su-Jin;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.123-130
    • /
    • 2014
  • A simultaneous determination was developed for 9 aminoglycoside antibiotics (amikacin, apramycin, dihydrostreptomycin, gentamicin, hygromycin B, kanamycin, neomycin, spectinomycin, and streptomycin) in meat by liquid chromatography tandem mass spectrometry (LC-MS/MS). Each parameter was established by multiple reaction monitoring in positive ion mode. The developed method was validated for specificity, linearity, accuracy, and precision based on CODEX validation guideline. Linearity was over 0.98 with calibration curves of the mixed standards. Recovery of 9 aminoglycosides ranged on 60.5~114% for beef, 60.1~112% for pork and 63.8~131% for chicken. The limit of detection (LOD) and limit of quantification (LOQ) were 0.001~0.009 mg/kg and 0.006~0.03 mg/kg, respectively in livestock products including beef, pork and chicken. This study also performed survey of residual aminoglycoside antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Aminoglycosides were not found in any of the samples.