• Title/Summary/Keyword: ion detection

Search Result 665, Processing Time 0.035 seconds

Whole genome sequencing analysis on antibiotic-resistant Escherichia coli isolated from pig farms in Banten Province, Indonesia

  • Hadri Latif;Debby Fadhilah Pazra;Chaerul Basri;I Wayan Teguh Wibawan;Puji Rahayu
    • Journal of Veterinary Science
    • /
    • v.25 no.3
    • /
    • pp.44.1-44.13
    • /
    • 2024
  • Importance: The emergence and rapid increase in the incidence of multidrug-resistant (MDR) bacteria in pig farms has become a serious concern and reduced the choice of effective antibiotics. Objective: This study analyzed the phylogenetics and diversity of antibiotic resistance genes (ARGs) and molecularly identified the source of ARGs in antibiotic-resistant Escherichia coli isolated from pig farms in Banten Province, Indonesia. Methods: Forty-four antibiotic-resistant E. coli isolates from fecal samples from 44 pig farms in Banten Province, Indonesia, were used as samples. The samples were categorized into 14 clusters. Sequencing was performed using the Oxford Nanopore Technologies MinION platform, with barcoding before sequencing with Nanopore Rapid sequencing gDNA-barcoding (SQK-RBK110.96) according to manufacturing procedures. ARG detection was conducted using ResFinder, and the plasmid replicon was determined using PlasmidFinder. Results: Three phylogenetic leaves of E. coli were identified in the pig farming cluster in Banten Province. The E. coli isolates exhibited potential resistance to nine classes of antibiotics. Fifty-one ARGs were identified across all isolates, with each cluster carrying a minimum of 10 ARGs. The ant(3'')-Ia and qnrS1 genes were present in all isolates. ARGs in the E. coli pig farming cluster originated mainly from plasmids, accounting for an average of 89.4%. Conclusions and Relevance: The elevated potential for MDR events, coupled with the dominance of ARGs originating from plasmids, increases the risk of ARG spread among bacterial populations in animals, humans, and the environment.

Establishment of a Method for the Analysis of Diarrhetic Shellfish Poisoning by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS를 이용한 설사성패류독소의 분석조건 확립)

  • Lee, Ka-Jeong;Suzuki, Toshiyuki;Kim, Poong-Ho;Oh, Eun-Gyoung;Song, Ki-Cheol;Kim, Ji-Hoe
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.458-463
    • /
    • 2009
  • To establish and validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and accurate quantitation of diarrhetic shellfish poisoning (DSP) toxins, we compared the results from different mobile phases and columns used for their analysis and collision energies for MS/MS experiments. Clear peaks of okadaic acid (OA) and dinophysistoxin-1 (DTX1) were obtained by using a mobile phase comprising aqueous acetonitrile containing 2 mM ammonium formate and 50 mM formic acid. The collision energies were optimized to facilitate the most sensitive detection for each toxin, namely, OA, DTX1, pectenotoxin-2 (PTX2), or yessotoxin (YTX). Further, the maximum ion response was obtained at a collision energy of 48 V for OA and DTX1. We compared the analytical performance of $C_8$ and $C_{18}$ columns. A wide range of toxins namely, OA, DTX1, PTX2, and YTX, except DTX3, were detected by both the columns. Although DTX3 was only detected by the $C_8$ column, we found that the $C_{18}$ column was also suitable for the quantitation of OA and DTX1 the toxins responsible for inducing diarrhea. The limit of detection of OA and DTX1 by the established LC-MS/MS conditions was 1 ng/g, and the limit of quantitation of the toxins under the same conditions was 3 ng/g. The process efficiencies were 91-118% for oysters (Crassostrea gigas) and 96-117% for mussels (Mytilus galloprovincialis) further, we observed no significant effect of matrix during the ionization process in LC-MS/MS. The comparison between mouse bioassay (MBA) and LC-MS/MS yielded varying results because low concentrations of OA and DTX1 were detected by LC-MS/MS in some shellfish samples, which provided positive results on MBA for DSP. The analysis time required by MBA for DSP analysis can be reduced by LC-MS/MS.

Study on High Sensitivity Metal Oxide Nanoparticle Sensors for HNS Monitoring of Emissions from Marine Industrial Facilities (해양산업시설 배출 HNS 모니터링을 위한 고감도 금속산화물 나노입자 센서에 대한 연구)

  • Changhan Lee;Sangsu An;Yuna Heo;Youngji Cho;Jiho Chang;Sangtae Lee;Sangwoo Oh;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.30-36
    • /
    • 2022
  • A sensor is needed to continuously and automatically measure the change in HNS concentration in industrial facilities that directly discharge to the sea after water treatment. The basic function of the sensor is to be able to detect ppb levels even at room temperature. Therefore, a method for increasing the sensitivity of the existing sensor is proposed. First, a method for increasing the conductivity of a film using a conductive carbon-based additive in a nanoparticle thin film and a method for increasing ion adsorption on the surface using a catalyst metal were studied.. To improve conductivity, carbon black was selected as an additive in the film using ITO nanoparticles, and the performance change of the sensor according to the content of the additive was observed. As a result, the change in resistance and response time due to the increase in conductivity at a CB content of 5 wt% could be observed, and notably, the lower limit of detection was lowered to about 250 ppb in an experiment with organic solvents. In addition, to increase the degree of ion adsorption in the liquid, an experiment was conducted using a sample in which a surface catalyst layer was formed by sputtering Au. Notably, the response of the sensor increased by more than 20% and the average lower limit of detection was lowered to 61 ppm. This result confirmed that the chemical resistance sensor using metal oxide nanoparticles could detect HNS of several tens of ppb even at room temperature.

Establishment of Choline Analysis in Infant Formulas and Follow-up Formulas by Ion Chromatograph (이온크로마토그래프를 이용한 조제유류 및 영아용·성장기용 조제식 중 콜린 함량 분석법 연구)

  • Hwang, Kyung Mi;Ham, Hyeon Suk;Lee, Hwa Jung;Kang, Yoon Jung;Yoon, Hae Seong;Hong, Jin Hwan;Lee, Hyoun Young;Kim, Cheon Hoe;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.411-417
    • /
    • 2017
  • This study was conducted to establish the analysis method for the contents of choline in infant formulas and follow-up formulas by ion chromatograph (IC). To optimize the method, we compared several conditions for extraction, purification and instrumental measurement using spiked samples and certified reference material (CRM; NIST SRM 1849a) as test materials. IC method for choline was established using Ion Pac CG column and 18 mM $H_2SO_4$ mobile phase. The parameters of validation were specificity, linearity, LOD, LOQ, recovery, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity, $R_2$ was over 0.999 in range of 0.5~10 mg/L. The detection limit and quantification limit were 0.14, 0.43 mg/L. The accuracy and precision of this method using CRM were 95%, 2.1% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested products were acceptable contents of choline compared with component specification for nutrition labeling. The standard operating procedures were prepared for choline to provide experimental information and to strengthen the management of nutrient in infant formula and follow-up formula.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Rec-assay and DNA-breaking Action on the Engymatic Browning Reaction Products -Influence of Cupric Ion Concentration- (효소적(酵素的) 갈변반응(褐變反應) 생성물(生咸物)에 대(對)한 Rec-assay 및 DNA 절단(切斷) 작용(作用) -동(銅) Ion 농도(濃度)의 영향(影響)-)

  • Ham, S.S.;Park, B.K.;Lee, S.Y.;Lee, J.H.;Kang, C.K.;Lee, D.S.;Omura, Hirohisa
    • Applied Biological Chemistry
    • /
    • v.27 no.4
    • /
    • pp.264-270
    • /
    • 1984
  • In order to obtain mutagenic data of enzymatic browning reaction products, we investigated their mutagenicity. The rec-assay with Bacillus subtilis strains $H17(rec^+)$ and $M45(rec^-)$ were carried out with their spores. Detection of double strand breakage in calf-thymus DNA was investigated into sample solution with and without $Cu^{2+}$ by the agarose slab gel electrophoresis. In the rec-assay, catechol, pyrocatechol, DL-dopa, 3,4-dihydroxytoluene, hydroquinone, hydroxyhydroquinone with and without $Cu^{2+}$ in 0.05M ana 0.1M at the enzymatic browning reaction products stowed mutagenic action. And also browning solution of 0.05M hydroxyhydroquinone and catechol with $Cu^{2+}$, hydroquinone with and without $Cu^{2+}$ of 0.1M at the enzymatic browning reaction products were strong mutagenic action. The DNA breakability of the enzymatic browning reaction products of 0.1M pyrogallol was stronger than that of 0.05M pyrogallol browning solution with $Cu^{2+}$ and 3,4-dihydroxytoluene browning solution was stronger than that of 0.01M 3,4-dihydroxytoluene browning solution.

  • PDF

Determination of homogentisic acid in human plasma by GC-MS for diagnosis of alkaptonuria (GC-MS를 이용한 혈장 중 호모겐티식산의 분석;알캅톤뇨증의 진단)

  • Thapa, Maheshwor;Yu, Jundong;Lee, Wonjae;Islam, Fokhrul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-330
    • /
    • 2015
  • Alkaptonuria, a rare inherited metabolic disease, is characterized by a lack of homogentisate dioxygenase and accumulation of homogentisic acid (HGA), leading to homogentisic aciduria, arthritis, and ochronosis. In this study, a rapid analytical method, without an expensive and tedious solid phase extraction step, was developed to quantify HGA in plasma using GC-MS. HGA-spiked pooled plasma samples were subjected to liquid-liquid extraction (LLE) with ethyl acetate, followed by trimethylsilyl derivatization (TMS) and GC-MS quantification using selected ion monitoring. The formation of TMS derivative of the 1 carboxylic and 2 hydroxyl functional groups was performed by reacting BSTFA (with 10% TMCS) for 5 min at 80 ℃. For selected ion monitoring, quantification and confirmation ions were determined based on specific ions (m/z 384, m/z 341 and m/z 252) of the TMS derivative of HGA. Calibration curves of pooled normal plasma specimens showed a linear relationship in the range of 1-100 ng/µL. The precision and accuracy were within a relative standard deviation (RSD) of 1 to 15% and a bias of -5 to 25%. Recoveries were obtained in the range of 99-125% and 95-115% for intra-day and inter-day assay, respectively, at 2, 20 and 80 ng/µL. The limit of detection (LOD) and limit of quantification (LOQ) were 0.4 ng/µL and 4 ng/µL, respectively. No homogentisic acid was excreted from normal Korean plasma samples. Collectively, the results from the present study suggest that this method could be useful for routine diagnosis and therapeutic monitoring of alkaptonuria patients with excellent sensitivity and rapidity.

Analytical Methods of Hydroxyl Radical Produced by TiO2 Photo-catalytic Oxidation (TiO2 광촉매 산화 반응에서 생성된 수산기 라디칼 분석 방법)

  • Kim, Seong Hee;Lee, Sang-Woo;Kim, Jeong Jin;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • The performance of $TiO_2$ photo-catalytic oxidation process is significantly dependent on the amount of hydroxyl radicals produced during the process, and it is an essential prerequisite to quantify its production. However, precise and accurate methods for quantification of hydroxyl radicals have not been developed so far. For this reason, this study was initiated to compare existing methods for analysis of hydroxyl radicals produced by $TiO_2$ photo-catalytic oxidation and to propose a new method to overcome the limitation of established methods. To simulate $TiO_2$ photo-catalytic oxidation process, Degussa P25 which has been widely used as a standard $TiO_2$ photo-catalyst was used with the dose of 0.05 g/L. The light source of process was UVC mercury low-pressure lamp (11 W, $2,975mW/cm^2$). The results indicate that both potassium iodide (KI)/UV-vis spectrometer and terephthalic acid (TPA)/fluorescence spectrometer methods could be applied to qualitatively measure hydroxyl radicals via detection of triiodide ion ($I_3{^-}$) and 2-hydroxyterephthalic acid which are produced by reactions of iodine ion ($I^-$) and TPA with hydroxyl radicals, respectively. However, it was possible to quantitatively measure hydroxyl radicals using TPA method coupled with high-performance liquid chromatograph (HPLC). The analytical results using TPA/HPLC method show that hydroxyl radical of 0.013 M was produced after 8 hours operation of photo-catalytic oxidation under specific experimental conditions of this study. The proposed method is expected to contribute to precise the evaluation of the performance of photo-catalytic oxidation process.

Quantitative determination of inosine 5'-monophosphate dehydrogenase activity in human peripheral blood mononuclear cells by ion-pair reversed-phase high-performance liquid chromatography (이온쌍 역상 HPLC를 이용한 인체 말초혈액단핵구에서 이노신 5'-일인산 탈수소효소 활성의 정량적 측정)

  • Shin, Hye-Jin;Kwon, Soon-Ho;Park, Ji-Myeong;Kwon, Soon-Hyo;Lee, Kyoung-Ryul;Kim, Young-Jin;Lee, Sang-Hoo
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.531-536
    • /
    • 2010
  • A quantitative analytical method has been established for the measurement of inosine 5'-monophosphate dehydrogenase (IMPDH) activity in human peripheral blood mononuclear cells (PBMCs) by ion-pair reversed-phase high performance liquid chromatography equipped with ultraviolet detection (HPLC/UV). IMPDH is a ${\beta}$-nicotinamide adenine dinucleotide hydrate (NAD+)-dependent dehydrogenase in which the enzyme converts inosine 5'-monophosphate (IMP) into xanthosine 5'-monophosphate (XMP). Its activity was measured by quantifying a HPLC chromatogram corresponding to XMP produced during the incubation of lysed PBMCs with IMP as a substrate and $NAD^+$ as a coenzyme. XMP produced was detected at a wavelength of 260 nm. The mobile phase was composed of a mixture of 37 mM potassium dihydrogen phosphate containing 7 mM tetra-n-butylammonium hydrogen sulfate adjusted to pH 5.5 and methanol (85:15, v/v) with a flow rate of 1 mL/min. The calibration curve was linear ($r^2$=0.999999) in the range of $0.2-50.0\;{\mu}M$ and the limit of quantification (LOQ) was $0.2\;{\mu}M$. The intra- and inter-day precisions were between 0.88-1.47% and 0.85-5.24%, respectively. The intra- and inter-day accuracies were between 98.74-99.99% and 99.95-101.65%, respectively. IMPDH activity in 11 Korean healthy volunteers ranged from 18.29 to 36.60 nmol/h/mg protein (mean = $27.70{\pm}6.28\;nmol/h/mg$ protein).

Optimization of HPLC Method and Clean-up Process for Simultaneous and Systematic Analysis of Synthetic Color Additives in Foods (식품 중 타르색소의 동시분석 및 계통분석을 위한 HPLC 분석조건 및 정제과정 확립)

  • Park, Sung-Kwan;Hong, Yeun;Jung, Yong-Hyun;Lee, Chang-Hee;Yoon, Hae-Jung;Kim, So-Hee;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.33-39
    • /
    • 2001
  • To develop a method for separation process using Sep-pak $C_18$, simultaneous and systematic analysis of 8 permitted and 11 non-permitted synthetic food colors in Korea, optimization of analysis conditions for reverse phase ion-pair high performance liquid chromatography was carried out. For the best result of Sep-pak $C_18$ separation the pH of color standard mixture solution was $5{\sim}6$ and 0.1% HCl-methanol solution were set as eluent. The colors eluated from Sep-pak $C_18$ cartridge were determined and confirmed by high performance liquid chromatography with a photodiode array detector at 420 nm for yellow colors type, at 520 nm for red colors type, at 600 nm for blue and green colors type and at 254 nm for mixed colors. Conditions for HPLC analysis were as follows: column, Symmetry $C_18$ (5 m, 3.9 mm $i.d.{\times}150\;mm$); mobile phase, 0.025 M ammonium acetate (containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (65 : 25 : 10) and 0.025 M ammonium acetate(containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (40 : 50 : 10); flow rate, 1 mL/min. It takes 35 minutes for simultaneaus analysis and 18 minutes for systematic analysis. The detection limits range of each colors were $0.01{\sim}0.05\;{\mu}g/g$.

  • PDF