• 제목/요약/키워드: ion beam methods

검색결과 141건 처리시간 0.027초

Simulation of an X-ray Fresnel Zone Plate with Nonideal Factors

  • Chen, Jie;Fan, Quanping;Wang, Junhua;Yuan, Dengpeng;Wei, Lai;Zhang, Qiangqiang;Liao, Junsheng;Xu, Min
    • Current Optics and Photonics
    • /
    • 제4권1호
    • /
    • pp.9-15
    • /
    • 2020
  • Fresnel zone plates have been widely used in many applications, such as x-ray telescopes, microfluorescence, and microimaging. To obtain an x-ray Fresnel zone plate, many fabrication methods, such as electron-beam etching, ion-beam etching and chemical etching, have been developed. Fresnel zone plates fabricated by these methods will inevitably lead to some nonideal factors, which have an impact on the focusing characteristics of the zone plate. In this paper, the influences of these nonideal factors on the focusing characteristics of the zone plate are studied systematically, by numerical simulations based on scalar diffraction theory. The influence of the thickness of a Fresnel zone plate on the absolute focusing efficiency is calculated for a given incident x-ray's wavelength. The diffraction efficiency and size of the focal spot are calculated for different incline angles of the groove. The simulations of zone plates without struts, with regular struts, and with random struts are carried out, to study the effects of struts on the focusing characteristics of a zone plate. When a Fresnel zone plate is used to focus an ultrashort x-ray pulse, the effect of zone-plate structure on the final pulse duration is also discussed.

다용도 팬톰에서 정위방사선수술기법의 선량 정확도 확인 (Confirmation of the Dose Distribution by Stereotactic Radiosurgery Technique with a Multi-purpose Phantom)

  • 유형준;김일한;하성환;박찬일;허순녕;강위생
    • Radiation Oncology Journal
    • /
    • 제20권2호
    • /
    • pp.179-185
    • /
    • 2002
  • 목적 : 본 교실에서 개발한 정위방사선수술 시스템의 정도관리를 위하여 다용도 팬톰을 제작하고 정위방사선수술 기법의 선량의 정확도를 확인하려 하였다. 대상 및 방법 : CL2100C 선형가속기에서 발생하는 6 MV 엑스선을 사용하여 정위적 방사선수술을 시행하였고 Farmer형 이온함, 0.125 cc 이온함, 다이오드 검출기 등을 정위 기준기구가 부착된 팬톰내에 설치한 후 선량을 측정하였다. 고정 빔, $20^{\circ}\~100^{\circ}$의 각도를 갖는 단일회전빔, 복합회전빔 등의 방사선조사 조건에서 측정기와 팬톰의 상대적 위치를 변화시키면서 측정하였다. 내경이 10, 20, 30, 40 mm인 원형의 3차 콜리메이터를 사용하였다. 결과 : 고정 빔, 단일 회전빔, 5개의 회전 빔으로 구성된 복합회전빔 등에서의 선량오차는 Farmer형 이온함으로 측정한 경우는 $0.5\%$ 이하, 0.125 cc 이온함의 경우에는 $0.5\%$, 다이오드 검출기인 경우에는 $2\%$ 이내였다. 결론 : 본 교실 개발 정위방사선수술 기법에 의한 방사선 조사선량의 정확도를 확인하였으며 이 자료는 향후 정위방사선수술 및 다분할 방사선치료의 정도관리에 유용한 기초자료로 활용될 것이다.

변형막 식각 방법에 따른 탄화규소 쇼트키 다이오드의 전기적 특성 (Electrical characteristics of SiC schottky diodes treated by the various dry etch methods for a damaged surface)

  • 최영민;강인호;방욱;주성재;김상철;김남균;김성진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.232-233
    • /
    • 2008
  • The 4H-SiC schottky diodes treated by the various dry etch methods were fabricated and electrically characterized. The post etch process including an Inductively Coupled Plasma(ICP) etch and a Neutron Beam Etch(NBE) was performed after a high-temperature activation annealing without graphite cap in order to eliminate the damaged surface generated during the activation annealing. The reverse leakage current of diode treated by ICP was 1/35 times lower than that of the diode without any post etch at the anode bias of -100V, while the reverse leakage current of diode treated by NBE was 1/44 times lower at the same bias.

  • PDF

표면처리가 다른 5종 임플랜트의 안정성에 관한 연구 (A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS)

  • 김선종;신상완;정성민;류재준
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

납 표준물질을 이용한 방사성동위원소 Thallium-201의 화학적 분리공정 개발 (Development of Chemical Separation Process for Thallium-201 Radioisotope with Lead Standard Material)

  • 이준영;김태현;박정훈
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.543-549
    • /
    • 2023
  • Thallium-201 (201Tl) is a medical radioisotope which emits gamma rays when it decays and used in myocardial perfusion scans in single-photon emission tomography due to its similar properties to potassium. Currently, the Korea Institute of Radiological & Medical Sciences is the only institution producing 201Tl in Korea, and optimization of 201Tl production research is necessary to meet supply compared to domestic demand. To this end, technical analysis of plating target production and chemical separation methods essential for 201Tl production research is conducted. It deals with the process of generating and separating 201Tl radioisotope and target production, It can be generated through a nuclear reaction such as natHg(p,xn)201Tl, 201Hg(p,n)201Tl, natPb(p,xn)201Bi → 201Pb → 201Tl, 205Tl(p,5n)201Pb → 201Tl, and considering impure nuclide generated simultaneously with the use of proton beam energy of 35 MeV or less, it is intended to be produced using the 203Tl(p,3n)201Pb→201Tl nuclear reaction. In particular, the chemical separation of Tl is a very important element, and the chemical separation methods that can separate it is broadly divided into four types, including solid phase extraction, liquid-liquid, electrochemical, and ion exchange membrane separation. Some chemical separations require additional separation steps, such as methods using selective adsorption. Therefore, this technical report describes four chemical separation methods and seeks to separate high-purity 201Tl using a method without additional separation steps

고온용 MEMS 재료의 마이크로 파괴거동에 관한 연구 (A Study on the Micro-fracture Behavior of the MEMS Material at Elevated Temperature)

  • 우병훈;배창원;문경만;배성열;;김윤해
    • 대한기계학회논문집A
    • /
    • 제31권5호
    • /
    • pp.550-555
    • /
    • 2007
  • The effective fracture toughness testing of materials intended for application in Micro Electro Mechanical Systems (MEMS) devices is required in order to improve understanding of how micro sized material used in device may be expected to perform upon the micro scale. ${\gamma}$-TiAl based materials are being considered for application in MEMS devices at elevated temperatures. Especially, in Alloy 4, both ${\alpha}_2$ and ${\gamma}$ lamellae were altered markedly in 3,000 h, $700^{\circ}C$ exposure. Parallel decomposition of coarse ${\alpha}_2$ into bunches of very fine (${\alpha}_2+{\gamma}$) lamellae. Parallel decomposition of coarse ${\alpha}_2$ into bunches of very fine (${\alpha}_2+{\gamma}$) lamellae. The materials were examined 2 types Alloy 4 on heat exposed specimen($700^{\circ}C$, 3,000 h) and no heat exposed one. Micro sized cantilever beams were prepared mechanical polishing on both side at $25{\sim}30{\mu}m$ and electro final stage polishing to observe lamellar orientation of same colony with EBSD (Electron Backscatter Diffraction Pattern). Through lamellar orientation as inter-lamellae or trans-lamellae, Cantilever beam was fabricated with Focused Ion Beam(FIB). The directional behavior of the lamellar structure was important property in single material, because of the effects of the different processing method and variations in properties according to lamellar orientation. In MEMS application, it is first necessary to have a reliable understanding of the manufacturing methods to be used to produce micro structure.

장경간 강바닥판 케이블교량에 적용하기 위한 폴리우레탄 폴리머콘크리트의 공용특성 연구 (A Study to Evaluate Performance of Poly-Urethane Polymer Concrete for Long-Span Orthotropic Steel Bridge)

  • 박희영;이정훈;곽병석;최이현;김태우
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.1-9
    • /
    • 2013
  • PURPOSES: The purpose of this study is to evaluate physical properties, durability, fatigue resistance, and long-term performance of poly-urethane concrete (PU) which can be possible application of thin layer on long-span orthotropic steel bridge and to check structural stability of bridge structure. METHODS : Various tests of physical properties, such as flexural strength, tensile strength, bond strength and coefficient of thermal expansion tests were conducted for physical property evaluation using two types of poly urethane concrete which have different curing time. Freezing and thawing test, accelerated weathering test and chloride ion penetration test were performed to evaluate the effect of exposed to marine environment. Beam fatigue test and small scale accelerated pavement test were performed to assess the resistance of PU against fatigue damage and long-term performance. Structural analysis were conducted to figure out structural stability of bridge structure and thin bridge deck pavement system. RESULTS: The property tests results showed that similar results were observed overall however the flexural strength of PUa was higher than those of PUb. It was also found that PU materials showed durability at marine environment. Beam fatigue test results showed that the resistances of the PUa against fatigue damage were two times higher than those of the PUb. It was found form small scale accelerated pavement test to evaluate long-term performance that there is no distress observed after 800,000 load applications. Structural analysis to figure out structural stability of bridge structure and thin bridge deck pavement system indicated that bridge structures were needed to increase thickness of steel deck plate or to improve longitudinal rib shape. CONCLUSIONS: It has been known that the use of PU can be positively considered to thin layer on long-span orthotropic steel bridge in terms of properties considered marine environment, resistance of fatigue damage and long-term performance.

이온 조사된 Cu/Ni/Cu(001)/Si 자성박막에 있어서 X-ray reflectivity를 이용한 계면 연구 (Interface study of ion irradiated Cu/Ni/Cu(001)/Si thin film by X-ray reflectivity)

  • 김태곤;송종한;이택휘;채근화;황현미;전기영;이재용;정광호;황정남;이준식;이기봉
    • 한국자기학회지
    • /
    • 제12권5호
    • /
    • pp.184-188
    • /
    • 2002
  • 수직자기이방성을 가지는 Cu/Ni/Cu(002)/Si(100) 자성박막을 전자빔 증발법을 이용하여 초고진공에서 증착 하였다. 증착 시 RHEED로 측정 한 결과 실리콘 기판 위에 자성박막이 적층성장되었음을 확인하였다. 이러한 Cu/Ni/Cu(001)/Si(100) 자성박막에 1 MeV C 이온을 이온선량 2$\times$$10^{16}$ ions/$\textrm{cm}^2$로 조사한 후 MOKE로 자기이력곡선을 측정한 결과 이온 조사에 의해 자화용이축이 수직에서 수평방향으로 변화되었음을 확인하였다 포항 방사광가속기를 이용하여 X-선 반사도와 Grazing Incident X-ray diffraction(GE) 분석을 수행한 결과 첫 번째 Cu층과 Ni층 사이의 계면은 이온 조사 후 거칠기는 증가하였으나, Cu와 Ni의 전자밀도의 대비는 더욱 명확해졌다. 그리고, 증착 후 Cu와 Ni원자의 격자 상수 차이에 의해 Ni층이 가지고 있었던 strain은 이온 조사 후 완화되었음을 알 수 있었다. 끝으로, 이온조사 시 자성특성 변화와 직접적인 관계가 있는 strain 완화, 계면 혼합층(혹은 새로운 상)등이 생성되는 기구를 탄성충돌 및 비탄성충돌에 의한 열화학적 구동력으로 규명하였다.

고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상 (The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam)

  • 추성실;이창걸;김귀언
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.449-454
    • /
    • 1993
  • 종양치료를 위하여 고에너지 X-선 또는 감마선을 인체에 조사할 경우 피부 표면 선량이 최대지점 선량의 $30~60\%$에 불과 함으로 피부보호 효과(Skin sparing effect)를 얻을 수 있는 장점을 갖고있다. 그러나 종양특성과 발병위치에 따라 조사면을 크게 하거나 선속내에 차폐물질 또는 보상여과판을 설치하여 치료할 경우 피부보호 효과가 감소되거나 없어지는 경우가 있고 이것은 종양치료에 중요한 요인이 되고 있다. 연세 암전문병원에 설치된 코발트 60원격치료기와 선형가속기에서 발생되는 4 MV및 10 MV x-선에 대한 피부선량을 측정하였으며 차폐물고정판(Tray) 구성 물질의 종류와 조사면의 크기 및 피부와 고정판간의 거 리에 따른 피부선량의 변화를 평가하였다. 방사선 조사면이 $15{\times}15\;cm^2$ 이상 넓고 피부와 collimator 간의 거리가 30 cm 이상일 때 피부 표면선량은 코발트 -60, 4, 10 MV에서 각각최대선량의 40, 30, $20\%$로 감소하였으며 조사면의 크기와 차폐 고정판의 물질에 따라 증감하였다. 차폐물을 고정시키는 고정판을 Lucite로 제작하고 고정판과 피부간의 거리를 약 15 cm 이상 간격을 주면 표면선량을 $50\%$로 줄일 수 있었고 주석, 구리, 납등을 부착시키면 전방산란 선량비율이 감소되어 피부선량은 $35\%$로 피부보호 효과를 얻을 수 있었다. 방사선의 전방산란비율은 에너지와 흡수물질의 원자번호에 관계되며 납과 주석 이 각각 코발트-60 감마선과 4~10 MV x-선의 전방산란비를 가장 크게 감소시켰다.

  • PDF

고에너지 방사선치료용 on-line 선량측정시스템을 위한 알고리즘의 개발 (Development of the Algorithm for On-line Dosimetry System for High Energy Radiation Treatment)

  • 우홍균;하성환
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.207-218
    • /
    • 1997
  • 목적 : 고에너지 방사선치료용 on-line 선량측정시스템의 개발의 일부로서, 측정된 투과선량을 이용하여 종양선량을 계산하는데 필요한 알고리즘의 개발이 목적이다. 방법 첫번째로 다양한 크기의 조사야 (FS), 다양한 두께의 phantom (Tp), 다양한 거리의 phantom to chamber distance (PCD)에서 6 MV 및 10 MV X-선에 대하여 특수 제작한 water phantom을 대상으로 phantom의 후방에서 투과선량을 측정하여 기본적인 beam data를 얻었다. 선원-측정기간 거리는 150cm으로 고정시켰다. 측정은 0.125cc ion chamber를 이용하였다. 두번째로 노출환경 (조사야의 크기, phantom의 두께, PCD)과 측정치와의 상관관계에 대한 알고리즘을 개발하고, 마지막으로 측정치와 알고리즘에 의한 예상치를 비교하여 알고리즘의 정확성을 평가하였다. 결과 : 측정데이터를 이용하여 회귀분석을 시행해서 두가지 알고리즘을 개발하였다. 알고리즘 1은 PCD에 대한 2차 함수와 A/P (area-perimeter ratio)에 대한 3차 함수로 이루어져 있으며, 알고리즘 2는 log(A/P)에 대한 3차 함수와 PCD에 대한 3차 함수로 이루어져 있다. 알고리즘 1에서는 측정치와 예상치의 오차가 1.0% 미만이었고, 알고리즘 2에서는 측정치와 예상치의 오차가 거의 0.5% 미만이었다. 또한 알고리즘 2는 알고리즘 1을 사용할 때보다 적은 data를 가지고서도 더욱 정확하게 fitting 할 수 있었다. 따라서 fitting 상수들을 구하는데 필요한 측정시간을 알고리즘 1을 사용할 때보다 반으로 줄일 수 있었다. 결론 : phantom의 후방에서 측정한 투과선량을 이용하여, 임의의 Tp, PCD, FS에서 투과선량을 정확하게 예측할 수 있는 두가지의 알고리즘을 개발하였다. 향후 보조 장치에 의한 영향, 조사야 차폐의 영향, 신체조직의 조직특성 (불균일도, inhomogeneity), 신체 형태의 굴곡에 대한 연구를 완성하면 매치료시마다 종양에 흡수된 방사선량을 확인할 수 있는 on-line dosimetry가 가능할 것이다.

  • PDF