• Title/Summary/Keyword: inverter-based

Search Result 1,290, Processing Time 0.024 seconds

Modified Capacitor-Assisted Z-Source Inverter Topology with Enhanced Boost Ability

  • Ho, Anh-Vu;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1195-1202
    • /
    • 2017
  • This paper presents a novel topology named a modified capacitor-assisted Z-source inverter (MCA-ZSI) based on the traditional ZSI. The impedance network of the proposed MCA-ZSI consists of two symmetrical cells coupled with two capacitors with an X-shape structure, and each cell has two inductors, two capacitors, and one diode. Compared with other topologies based on switched ZSI with the same number of components used at impedance network, the proposed topology provides higher boost ability, lower voltage stress across inverter switching devices, and lower capacitor voltage stress. The improved performances of the proposed topology are demonstrated in the simulation and experimental results.

A Study of NMEA 2000 Protocol Application for Ship Electrical Power Converter Monitoring System (NMEA 2000 프로토콜을 적용한 선박 전력 컨버터 모니터링 시스템에 관한 연구)

  • Hong, Ji-Tae;Park, Dong-Hyun;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.288-294
    • /
    • 2011
  • In this paper, the FPGA-based SoC board (Xilinx Virtex-4 ML401 EVM) is adopted to control electrical power inverter system. For marine application, its performance is shown on PC-based system for monitoring electrical characteristics of a power inverter using by the NMEA 2000 protocol. This power inverter system is achieved in Real-Time monitoring and control by dual micro-processor operation on embedded FPGA-based SoC board. One micro processor is for control (Control processor) electrical power inverter using by PWM signal. And the other microprocessor (Communication processor) is for communication with PC-based monitoring system. The two-processor is communicating each other using by dual-port ram (DPRAM). PC-based system user can control and monitor information of the electrical power inverter via NMEA 2000 based communication processor. Control and monitoring information includes the inverter status and configuration. SoC board converts this information to Parameter Group Numbers (PGNs) in the NMEA 2000 protocol. This system can be applied to marine power electronics for distributed power generation, transmission or regulation systems on the ship.

Development And Application of Three-phase Inverter Output Wave Generator based on SPWM Control to Verify the Performance of LCL filters (LCL 필터의 성능 검증을 위한 SPWM 제어기반의 3상 인버터 출력 파형 발생 장치 개발 및 적용 연구)

  • Im, Dong-Kyun;Kang, Chang-Kyun;Ha, Won-Jin;Sandagdorj, Chuluunbaatar;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.841-852
    • /
    • 2022
  • In this paper, a 3-phase inverter output waveform generator based on SPWM control was developed to verify the performance of the LCL filter. In order to obtain a test signal for verifying the performance of the filter, first, a DSP-based 3-phase SPWM signal generation algorithm was developed, and then a three-phase voltage source inverter circuit was designed using three half-bridge gate drivers. Next, one LCL filter was experimentally fabricated to verify the effectiveness of the developed SPWM-based 3-phase inverter output waveform generator as a test signal generator, and a DSP-based performance verification system was experimentally constructed. Finally, by comparing the three-phase voltage waveform before and after the LCL filter obtained in the output control experiment with the given time ratio, the effectiveness of the SPWM-based 3-phase inverter output waveform generator was verified.

A New Simplified Vector Control For A High Performance Common-Arm IHCML Inverter (고성능 공통암 IHCML 인버터를 위한 새로운 벡터 제어 방식)

  • Song, Sung-Geun;Park, Sung-Jun;Nam, Hae-Kon;Kim, Kwang-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1071-1079
    • /
    • 2007
  • In this paper, a novel space vector control method for isolated multi-level inverter using 3-phase low frequency transformers is proposed. This method is based on the simplification of the space-vector diagram of a five-level inverter using calculated table into fully programming method. The execution time of the proposed method is about same as that of the method using calculated table. Also, the proposed method is easily applied to other case level inverter. We applied this method into the 3-phase IHCML inverter using common arm. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformers could be reduced compare with an exiting 3-phase multi-level inverter using single phase transformer. In addition, this method generates very low harmonic distortion operation with nearly fundamental switching frequency. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

Grid-Connected Three-Phase Inverter System with Sub Inverter using Combination Type UPFC Structure

  • Park, Seong-Mi;Vi, Le Thi Tuan;Jeong, Da-Woom;Park, Sung-Jun;Park, Jang-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_1
    • /
    • pp.559-567
    • /
    • 2020
  • As the renewable energy market grows, grid-connected inverters have been improving and expanding in several fields in recent years because energy conversion devices are the main components of solar systems. In this paper, a high-precision new grid-connected three-phase inverter system is proposed. The proposed system consists of a main inverter, a sub inverter and a transformer. The main inverter operates at a low switching frequency and high power and transmits power to the grid. A sub-inverter connected in series with the transmission line through a matching transformer operates at lower power than the main inverter to provide input values to the transformer. The transformer acts as a power supply according to the voltage compensation value. This study is based on the principle of operation of the UPFC(Unified Power Flow Controller) structure used to regulate power flow in AC transmission lines. The grid-connected inverter system proposed in this paper is implemented with high precision and high resolution. The proposed system was verified through its ability to enhance and ensure the safety of the proposed system through simulation and experiment.

High-Frequency DC Link Inverter for Grid-Connected Photovoltaic System (고주파링크방식을 이용한 PV용 PCS의 고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1313-1315
    • /
    • 2002
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency inverter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AD filter. The high frequency inverter bridge switching at 20kHz is used to generate bipolar PWM pulse, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. In this paper, the control algorithm for synchronous current feedback control method and a maximum power point tracking (MPPT) method using DSP are described. And, the simulation and experimental results are shown to verify the validity of the proposed system.

  • PDF

Performance Test of an Integrated Electronic Protection Device Based Photovoltaic Inverter (지능형 보호기기 적용 태양광 인버터 성능시험)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1744-1750
    • /
    • 2007
  • This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.

High-Frequency Zero Current Soft Switching Inverter with Pulse Density Modulation for Induction Heated Roller

  • Kang, Shin-Chul;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.7
    • /
    • pp.49-57
    • /
    • 2008
  • This paper presents a voltage source type half-bridge series resonant high frequency (HF) inverter for induction heated fixing roller in copy machines. This high-frequency inverter works under zero current soft switching (ZCS) commutation and has wide power regulation range due to employing a pulse density modulation (PDM) scheme. Transient and steady state operating modes of the inverter are presented in this paper together with its PDM-based power regulation system. Experimental operating performances of the developed HF-ZCS inverter as well as power losses and actual efficiency are discussed and compared with computer simulation results.

Regenerative Inverter System for Railway with DC Line Voltage Simulator (직류가선전압 모의장치를 적용한 지하철용 회생인버터 시스템)

  • Ji, Young-Hyok;Cho, Ki-Hyun;Jang, Su-Jin;Won, Chung-Yuen;Kim, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1515-1521
    • /
    • 2007
  • In this paper, a unified regenerative inverter system for railway with DC line voltage simulator is proposed. In order to determine the operation characteristics of the regenerative inverter, the DC line voltage simulator is proposed. The DC line voltage simulator, which is based on the AC-DC PWM converter, varies the DC voltage according to the fluctuating voltage which is measured in the actual DC line. The suitable operating point of the regenerative inverter can be estimated from the simulation result. The regenerative inverter operates two modes. When the DC line voltage exceed the operating point, already set up, it works as regenerative inverter to return the excessive power of DC line to the grid. When the DC line voltage is under the operating point, it works as active power filter to compensate harmonic currents. In this paper, the control algorithm of the DC line voltage simulator and that of the regenerative inverter is proposed.

  • PDF

Single ZnO Nanowire Inverter Logic Circuits on Flexible Plastic Substrates (플랙시블 기판 위에서 제작된 단일 ZnO 나노선 inverter 논리 소자)

  • Kang, Jeong-Min;Lee, Myeong-Won;Koo, Sang-Mo;Hong, Wan-Shick;Kim, Sang-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.359-362
    • /
    • 2010
  • In this study, inverter logic circuits on a plastic substrate are built with two top-gate FETs in series on a single ZnO nanowire. The voltage transfer characteristics of the ZnO nanowire-based inverter logic circuit exhibit a clear inverting operation. The logic swing, gain and transition width of the inverter logic circuit is about 90 %, 1.03 and 1.2 V, respectively. The result of mechanical bending cycles of the inverter logic circuit on a plastic substrate shows that the stable performance is maintained even after many hundreds of bending cycles.