• Title/Summary/Keyword: inverter-based

Search Result 1,292, Processing Time 0.028 seconds

Advanced Maximum Power Point Tracking Method for the Series Operation Strategy of Grid-Connected Small Wind Turbines (계통연계형 소형풍력발전 시스템의 직렬운전을 고려한 개선된 MPPT 방법)

  • Kim, Yong-Hyu;Heo, Hong-Jun;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.497-505
    • /
    • 2016
  • Operating wind turbine generators at maximum power point requires maximum power point tracking (MPPT) control methods. However, conventional methods cannot track the appropriate maximum power point in situations involving wind turbine systems based on a series operation strategy. These systems comprise one or more local maximum power points, and conventional methods can detect only one local maximum power point closed by a current operation point. This study proposes an advanced MPPT method for the series operation strategy of a small, grid-connected wind turbine system. In determining the appropriate maximum point, operations at certain local maximum power points are analyzed. The results show one appropriate point, which is tracked by the proposed MPPT method. The effectiveness of the proposed method is verified by the experimental results.

An SCR Thyristor Based Three-Phase Voltage Disturbance Generator

  • Han, Heung-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.372-378
    • /
    • 2012
  • This paper deals with a 3-phase voltage disturbance generator for a performance test of custom power devices such as dynamic voltage restorers (DVR), dynamic uninterruptable power supplies (UPS), etc. The operating principle of the proposed circuit is described in each mode of voltage sag, swell, outage, and unbalance. The main components of the proposed disturbance generator are silicone controlled rectifier (SCR) thyristors, variable autotransformers, and transformers. Therefore, the disturbance generator can be implemented with a considerably low cost compared to the conventional pulse width modified (PWM) inverter and converter type generators. Furthermore, it has good features of high reliability with simple structure, high efficiency caused by no PWM switching of the SCR thyristors, and easy control with a wide variation range. To verify the validity of the proposed scheme, simulations and experiments are carried out.

A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters (단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구)

  • Hwang, Seon-Hwan;Hwang, Young-Gi;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.

On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication (Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템)

  • Chung, Wan-Sup;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.

Grid-tied Power Conditioning System for Battery Energy Storage Composed of 2-stage DC-DC converter (2단 DC-DC 컨버터로 구성된 배터리 에너지저장용 계통연계형 전력변환장치)

  • Park, Ah-Ryeon;Kim, Do-Hyun;Kim, Kyeong-Tae;Han, Byung-Moon;Lee, Jun-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1848-1856
    • /
    • 2012
  • This paper proposes a new grid-tied power conditioning system for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through theoretical analysis and computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

High Efficiency Operation of the IPT converter with Full and Half bridge Control for Electric Vehicles (전기자동차용 IPT 컨버터의 풀브릿지-하프브릿지 제어를 통한 고효율 운전 방법)

  • Ann, Sang-Joon;Joo, Dong-Myoung;Kim, Min-Kook;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.423-430
    • /
    • 2017
  • This paper proposes a control methodology for a high efficiency operation of an inductive power transfer (IPT) converter by combining full bridge (FB) and half bridge (HB) controls. To apply the proposed control to the IPT converter, the characteristics of each control method are analyzed. By examining the output voltages of the IPT converter and a theoretical loss analysis, the control shifting points between FB and HB controls are evaluated in accordance with the coupling coefficients and the load. Based on the control shifting points, the FB-HB control algorithm is implemented. By applying FB-HB control, high efficiency operation at the light load condition can be achieved.

The Implementation of a Discrete PI Speed Controller for an Induction Motor (유도전동기용 이상 PI형 속도제어기의 구성)

  • 김광배;고명삼
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.1
    • /
    • pp.26-35
    • /
    • 1986
  • In this paper, non-linear state equations for a 3-phase, 220V, 0.4 KW, squirrel cage induction motor have been derived using the d-q transformation and then these equations have been linearized around an operating point by a small perturbation method. Root loci on the s-plane with repect to the changes of slip S and supply frequency f have been studied. Based on the above results, the derived linear state equations have been augmented to the 6th order, including the output velocity feedback and a discrete PI speed controller. Using the new state equations, stability regions on the Kp-Kl plane have been investigated for slip S and sampling time T. In designing a discrete PI controller, the coefficients Kp and Kl around the normal operating point (220V,1,692rpm,60Hz)have been chosen under the assumptions that each response to a perturbation input of reference speed and load torque be underdamped and dominated by a pair of complex poles. Step responses in the experimental system using an Intel SDK-86 and an optimized PWM inverter show satisfactory results that the maximum overshoots and damped frequency are well coincided with ones from the computer simulation.

  • PDF

Novel Architecture for Efficient Implementation of Dimmable VPPM in VLC Lightings

  • Jeong, Jin-Doo;Lim, Sang-Kyu;Jang, Il-Soon;Kim, Myung-Soon;Kang, Tae-Gyu;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.36 no.6
    • /
    • pp.905-912
    • /
    • 2014
  • In this paper, a new architecture is proposed to achieve complexity efficiency in implementing variable pulse position modulation (VPPM). VPPM, specified in IEEE 802.15.7, can support wireless communication and dimming control simultaneously using visible light. The proposed architecture is based on the VPPM signal property in which the transition point of the modulated output is obtained by counting the sample index and comparing it to both the assigned dimming factor and the transmitting data. Therefore, the proposed architecture can be composed of simple logics, including a counter, a comparator, and an inverter, all of which are insensitive to the dimming resolution in contrast to a conventional codeword-table method. This paper describes the verification of the proposed algorithm through a register-transfer level implementation of the codeword and proposed architectures. In comparison with the codeword-table method, the proposed method gains a nine-fold complexity reduction at a 1% dimming-step resolution.

On-line Fault Detection and Diagnosis for Heat Exchanger of Variable Speed Refrigeration System Based on Current Information (전류정보를 이용한 가변속냉동시스템의 열교환기 실시간 고장 진단)

  • Lee, Dong-Gyu;Jeong, Seok-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.88-94
    • /
    • 2007
  • This study deals with on-line fault detection and diagnosis for heat exchanger of variable speed refrigeration system. Conventional studies about fault of heat exchanger in refrigeration system have used temperature and pressure information. The temperature and pressure are able to be used valuably for faults detection of constant speed refrigeration system. However in case of variable speed refrigeration system, the temperature and pressure are no longer useful information for fault detection due to compensation effect of feedback controller. While current information is possible to detect faults of variable speed refrigeration system. The current information was detected in an inverter, it was used after transforming rms value. The faults of variable speed refrigeration system are divided into electrical faults and mechanical faults. We performed fault detection and diagnosis about heat exchanger among mechanical faults such as condenser fouling and evaporator fan fouling through some experiments.

  • PDF

A High-Performance Speed Sensorless Control System for Induction Motor with Direct Torque Control (직접 토크제어에 의한 속도검출기 없는 유도전동기의 고성능 제어시스템)

  • Kim, Min-Huei;Kim, Nam-Hun;Baik, Won-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.1
    • /
    • pp.18-27
    • /
    • 2002
  • This paper presents an implementation of digital high-performance speed sensorless control system of an induction motor drives with Direct Torque Control(DTC). The system consists of closed loop stator flux and torque observer, speed and torque estimators, two hysteresis controllers, an optimal switching look-up table, IGBT voltage source inverter, and TMS320C31 DSP controller board. The stator flux observer is based on the combined current and voltage model with stator flux feedback adaptive control for wide speed range. The speed estimator is using the model reference adaptive system(MRAS) with rotor flux linkages for speed turning signal estimation. In order to prove the suggested speed sensorless control algorithm, and to obtain a high-dynamic robust adaptive performance, we have some simulations and actual experiments at low(20rpm) and high(1000rpm) speed areas. The developed speed sensorless system are shown a good speed control response characteristic, and high performance features using 2.2[kW] general purposed induction motor.