ZCS를 이용한 고주파 공진형 상용주파수 전원에 관한 연구 (A Study on Commercial Frequency Source with High Frequency Resonant Type using ZCS)

  • 김종해;김동희;노채균;구태근;배상준;이봉섭
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.448-454
    • /
    • 1999
  • This paper describes a new dc-ac inverter system which for achieving sinusoidal ac waveform makes use of parallel loaded high frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. A forced discontinuous conduction mode is used to realize the quasi-sinusoidal pulse in each switching period. Therefore the inverter generates sinusoidal modulated output voltage including carrier frequency that is resonant frequency. Carrier frequency components of modulated output voltage is filtered by low pass filter. Since current through switches is always zero at its turn-on in the proposed inverter, low stress and low switching loss is achieved. Operating characteristics of the proposed system is analyzed in per unit system using computer simulation. The output voltage of if includes low harmonics and it is almost close to sine wave. Also, the theoretical analysis is proved through the experimental test.

  • PDF

THE CHARACTERISTICS OF OUTPUT FOR INVERTER TYPE X-RAY GENERATOR

  • Lim, Hong-Woo;Han, Euam-Yong;Baek, Hyung-Lae;Lee, Seong-Kil
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.431-435
    • /
    • 1998
  • This paper deals with the output characteristics of resonant PWM inverter type X-ray generators connected to different DC power units i.e. a single phase full bridge rectifier, a three phase full bridge rectifier and a power storage unit(PSU). The quality of X-ray beam depend on the pulsation waveforms of DC voltage supplied to the X-ray tulbe. In a X-ray generator, the waveforme of DC output voltage can be affected from hramonic distortion of DC input power. When a tube voltage waveform is distorded, the property of X-ray beam such as reproducibility, direcibility and doesage can be reduced. Therefore, we compared DC output waveforms and doesages with three thpe of DC power units and show the experimental results in this paper

  • PDF

시분할 방식 VVVF형 고주파 공진 인버터의 특성해석 (Characteristics analysis of time sharing method VVVF type high frequency resonant inverter)

  • 조규판;원재선;남승식;심광렬;배영호;김동희
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.20-28
    • /
    • 2002
  • 본 논문은 고주파 유도가열용 전원에 사용되는 VVVF기능을 내장한 시분할 방식 고주파 공진 인버터 회로를 제시하였다. 제안한 인버터는 종래의 전압형 하프 브릿지 직렬 공진 인버터를 단위 인버터로 하여 이 단위 인버터 3개를 입력전원에 병렬로 접속하여 스위칭 주파수의 3배의 출력 주파수를 얻을 수 있으며, 또, 인버터 내부에 VVVW 기능을 부여하여 출력전압.주파수를 제어 할 수 있고 ZVS 기능도 가지고 있다는 특징을 가지고 있다. 회로의 해석은 정규화 파라메타를 도입하여 범용성 있게 기술하였고, 인버터 특성을 스위칭 주파수, Phase-Shift의 위상차각($\phi$) 변화와 제 파라메타에 따라 특성평가를 행하였다. 실험을 통해 이론해석의 타당성을 검증하였으며, 향후 유도가열 웅용, DC-DC 컨버터 등의 전원 시스템에 웅용 가능성을 보여주고 있다.

순차전압시스템을 고려한 독립형 태양광 발전 시스템에 관한 연구 (A Study on the Off-Grid Photovoltaic Generation System with Sequential Voltage System)

  • 김구용;배준형;김종해
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.364-367
    • /
    • 2020
  • 본 논문에서는 OR논리게이트를 적용한 순차전압제어방식의 독립형 PV-ESS 시스템을 나타내고 있다. 저압연계방식으로 용량확대에 따른 문제점들을 가지고 있었던 기존 독립형 PV-ESS 시스템에 고압의 아날로그 방식의 순차전압제어 방식을 적용함으로써 고효율, 저가격이 가능한 독립형 PV-ESS 시스템을 제안한다. 본 논문은 기존 24V 태양광 단위 모듈의 직렬연결 확장형 고압 배터리의 출력전압 384V을 3상 DC to AC 인버터의 입력 전압으로 하여 인버터의 출력 전압과 출력 전력을 AC380V@60Hz와 10kW로 구성하였다. PSIM 시뮬레이션에 의한 이론 해석의 타당성을 입증하기 위해 실험을 통해 OR 논리 게이트를 적용한 순차전압제어시스템의 동작 특성을 확인하였다.

구동 신호 Phasor 제어형 SIT 고주파 공진 인버터 (Drive Signal Phasor Control-Based High Frequency Resonant Inverter Using Power-SIT)

  • 김동희;노채균;김종해;정원영
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.51-57
    • /
    • 1998
  • 본 논문은 구동신호 위상제어 기능을 갖는 SIT고주파공진 인버터를 제안하였다. SIT를 이용한 위상제어형인버터는 낮은 스위칭 손실로서 높은 스위칭 주파수의 전력변환을 실현시킬 수 있다. 특히 2단위 인버터의 출력전압을 직렬로 연결하여 높은 출력을 얻을 수 있다. 과전류에 대해서 보호회로를 이용한 시스템의 안정성과 그리고 PLL에 의해 부하변화에 따른 자동추종제어를 실현하였다. 특히 제안된 인버터는 고주파에서도 거의 정현파에 가까우며, 스위칭 주파수 범위는 180∼220〔kHz〕이고, 2〔kW〕의 유도가열에 응용하였다. 본 인버터의 동작 특성에 대해서 이론과 실험결과를 비교 검토하였다.

  • PDF

대용량 GTO 구동회로용 Power Supply Unit 개발 (Development of Power Supply Unit for high power GTO driver)

  • 차재덕;양항준;홍순욱;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.609-612
    • /
    • 1996
  • This paper describes a design and implementation of the practical SMPS(Switched Mode Power Supply) with multi-output independent regulation scheme. The designed SMPS is applied to the PSU(Power Supply Unit) of high power GTO drivers for a inverter system. In order to accomplish precise voltage regulations for both turn-on and turn-off bias voltages of the GTO driver, the conventional forward type PWM converter scheme is adopted with the Post Regulator using a Saturable Reactor. Analytic design criteria and control schemes are described for practical applications. Finally, the precise regulation of multi-output voltages is proved by experimental results.

  • PDF

3,300V 1MVA H-브릿지 멀티레벨 인버터 개발 (Development of 3,300V 1MVA Multilevel Inverter using Series H-Bridge Cell)

  • 박영민;김연달;이현원;이세현;서광덕
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.478-487
    • /
    • 2003
  • 본 논문에서는 고압 대용량 전동기 구동용 멀티레벨 인버터의 종류 및 특징을 간략히 살펴보고, 특히 입출력 전력품질이 우수하고 전압별 시리즈화가 용이한 H-브릿지 멀티레벨 인버터의 구조적 특징 및 장점을 기술하였다. 연구 개발된 3,300V lMVA 용량의 Cascaded H-브릿지 멀티레벨 인버터의 구체적인 전력회로 구조 및 설계방법, 제어기 구성 그리고 PWM 기법을 제시하였다. 또한, 실용량의 시험을 통해 H-브릿지 멀티레벨 인버터는 출력 전압 Step이 여러 단계이고 dv/dt가 적으며 입력단 THD를 크게 낮출 수 있어 성능 면에서도 여타 방식보다 우수함을 입증하였다. 또한 생산적인 측면에서도 저압 소자를 사용하여 설계하므로 기존의 생산/시험 기술과 설비를 이용할 수 있어 매우 경제적이며 Power Cell 단위 결합 구조이므로 신뢰성 측면이나 보수/유지 측면에서도 유리하다는 결론을 얻었다.

PWM 콘버터와 공진형 인버터를 채용한 UPS 개발 (The development of an UPS using PWM Converter and Resonant Inverter)

  • 민병권;유승표;백병산;김연풍;신현주;김동욱;유동욱;백주원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.550-552
    • /
    • 1996
  • In order to develop a noble Uninterruptible Power Supply(UPS), we designed and manufactured the UPS using the PWM converter and the Resonant DC Link Inverter. This paper describes the power circuits, the key techniques, the control and monitoring unit of the developed UPS. Finally, using the UPS we verified the superiority through the type test.

  • PDF

위상보상기를 가진 인버터로 구동되는 영구자석형 동기전동기의 제어기 설계 (The Controller Design of the Permanent Magnet Synchronous Drive Using a Inverter with Phase Compensator)

  • 유정웅;우광준
    • 대한전기학회논문지
    • /
    • 제37권3호
    • /
    • pp.146-154
    • /
    • 1988
  • The computer simulation of speed and phase control system has been carried out in this study. The load of permanent magnet type synchronous motor is not constant in this system. The cost function method has been used in obtaining the optimal gain of PI controller and the rotor position angle of phase controller has been compensated depending on the load and speed variation. This analysis also shows that the current of d-axis component is zero under the variable a load conditions and the torque per unit current can be maximized.

  • PDF

인버터식 X선장치의 관전압 맥동율 개선에 관한 연구 (A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator)

  • 이성길;임홍우;조금배;정수복;백형래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF