교류 전기철도 전력계통의 고조파 예측량 계산 (Estimation of Harmonics on Power System of AC Electric Railway)

  • 송진호;황유모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권2호
    • /
    • pp.68-79
    • /
    • 2003
  • We estimated harmonics on power system of AC railway based on quantitatively measured harmonics and investigated the need of facilities for harmonics reduction. In order to analysis harmonics which inflow into power system due to increase in collector voltages and harmonic currents generated from the train when the railway is in operation, the railway system Is sectioned into power supply, railway line, AT, sectioning Post and subsectioning post. For analysis of extension of currents resulting from the railway loads, PWM converter, VVVF inverter and the feeder system are modeled based on the dynamic node technique(DNT). In order to test the usefulness of the DNT for analysis of harmonic effects, the measured harmonic currents and harmonic magnification ratios at the S/K substation are compared with simulation results using DNT modelling, which include the results for two cases with and without filters for suppression of harmonic currents. When 8 cars(4M4T) are in operation, the total sum of harmonic currents resulting from the train at M and T phases, which inflow into the substation along with the railway line, is calculated. Using the harmonics analysis program for railway feeder system with these data, the total harmonic distortion factor(710) at the outgoing point of KEPCO substation is computed. The calculation shows that when the maximum THD at the receiving point of H/K substation was 0.0443% which is much lower than 1.5% which is the allowable value of KEPCO at 154kV as well as IEEE-519 above 132kV This result indicates that any measure for harmonics reduction in Incheon International Airport Railway is not needed.

DC 전력선 통신을 이용한 Plug-in형 BLDC 구동 시스템 (Plug-in BLDC Control System using DC-link Communication)

  • 우도;송성근;이민중;김광헌;박성준
    • 전력전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.105-111
    • /
    • 2009
  • 현재 생활의 이기인 자동차 등에서 구동되는 기기의 전원은 배터리 전원을 주로 사용하고 있으며, 또한 산업체에 사용되는 인버터를 사용하는 기기에서도 DC 전원 사용이 확대되고 있다. 이와 같이 DC 전원이 사용되는 곳에서 전력선을 활용한 데이터 통신방식에 대한 수요가 급증할 것으로 사료된다. 본 논문에서는 DC 전원을 기반으로 하는 DC 전력선 통신을 이용하여 BLDC(Brushless DC) 전동기 구동시스템을 제안한다. 이 시스템의 특징은 인출되는 DC 전원으로 사용되는 2 선만으로 구성하여 데이터 통신을 할 수 있는 장점이 있다. 외부 설정치와 지령치로 사용되는 신호선을 제거하고 전력선과 엔코더 신호선의 단축으로 신뢰성 확보되며, 또한 멀티 제어 시 배선수의 최소화 및 회전기기 장착 시 슬립링 수를 최소화 할 수 있다. 위험한 환경에서도 안정성이 증가되며, 시스템 제작단가를 저감할 수 있다. 마지막으로 제안된 방식에 대한 우수성을 검증하기 위해서 PSIM 및 MATLAB를 활용하여 시뮬레이션을 실시하였고, 실제 프로토타입을 제작하여 실험을 통하여 그 타당성을 검증하였다.

5kW 급 주택용 고분자 연료전지 시스템 (Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation)

  • 양태현;박구곤;윤영기;이원용;윤왕래;김창수
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

원자력발전소 직류전원계통용 축전지 성능시험 분석 (Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant)

  • 김대식;차한주
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

비정상 과도상태에서의 해군 전투체계 UPS 개선 (Improvement of Naval Combat System UPS under Abnormal Transients)

  • 김성후;최한고
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.97-103
    • /
    • 2018
  • 본 논문에서는 비정상적인 과도상태에서의 개선된 해상 전투체계 UPS(Uninterruptable Power Supply) 시스템을 다룬다. 기존에는 일시적인 과전압 및 과전류에 대응하기 위하여 서미스터와 바리스터 소자를 사용하고 있지만 시스템 운용 중에 발생하는 비정상 과도전압에는 취약하므로 UPS가 비가용 상태로 되는 경우가 빈번히 발생하였다. 이를 극복하고 UPS 시스템을 보호하기 위하여 본 논문에서는 초기 입력전원 및 운용 중에 발생되는 비정상 과도전압을 감지한 입력 전원 차단회로, 전원제어 시퀀스 개선, 그리고 인버터 및 CPU 오동작 방지 방법 등을 제안한다. 제안된 방법으로 UPS 구현된 시스템은 Programmable AC/DC 발생기를 이용하여 입력전원 가변 시험을 통하여 시뮬레이션을 수행하였으며, 최종적으로 해상 전투체계의 다기능콘솔에 장착하여 현장시험을 통하여 신뢰성과 안정성을 검증하였다.

보조 전원을 이용한 12 펄스 다이오드 정류기를 사용하는 추진시스템의 고조파 및 토크 리플 저감 (Harmonic and Torque Ripple Reduction of Electric Propulsion System using 12-Pulse Diode Rectifier by Auxiliary Supply)

  • 김종수;서동환;최재혁
    • 해양환경안전학회지
    • /
    • 제19권1호
    • /
    • pp.66-70
    • /
    • 2013
  • 전기추진선박의 추진시스템에 주로 사용되는 3상 정류기의 입력전류는 다양한 저차 고조파를 포함하고 있다. 이러한 고조파 저감을 위해서 대전력이 필요한 대형 선박에 사용되는 전력변환장치는 12펄스 출력의 정류기가 현재 사용되고 있지만 여전히 $12{\pm}1$차의 고조파가 발생되는 문제점이 있다. 또한, 속도 및 토크 제어기법으로 널리 사용되고 있는 직접토크제어기법의 경우에는 토크 리플이 심하고 전동기의 입력전류는 인버터의 스위칭에 의해 고조파를 크게 포함하고 있다. 본 연구에서는 직접토크제어기법을 이용하는 전기추진시스템의 12펄스 정류기에 보조 전원을 공급하여 고조파를 저감하고 토크 제어성능을 향상시켰으며 실선시스템 환경에서 시뮬레이션을 통해 그 유효성을 입증하였다.

가정용 태양광/ESS 통합 스마트 PCS 개발 (Development of Smart PCS(Power Conditioning System) Integrating PV/ESS for Home)

  • 이상학
    • 디지털융복합연구
    • /
    • 제14권7호
    • /
    • pp.193-200
    • /
    • 2016
  • 최근 들어 가정 내 태양광과 에너지저장시스템을 도입하여 에너지 자립도를 높이고자 하는 기술 개발이 활발히 이루어지고 있다. 낮에 생산된 전기를 에너지 저장 시스템에 충전해 두고 전기요금이 높을 때 사용함으로써 효율적인 에너지 관리를 수행할 수 있다. 국내에서는 아직까지 가정용 실시간 요금제가 이루어지고 있지 않지만 누진제 상의 일정 목표까지 전기 사용량을 낮출 수 있다. 가정 내 태양광을 도입하기 위해서는 전력 변환장치인 PCS를 필요로 한다. PCS는 직류로 생산된 전력을 교류로 변환하여 사용하고 에너지 저장 시스템의 충방전을 수행하도록 한다. 에너지 자립형 스마트 홈 시스템은 태양광, 에너지저장시스템에 대한 일반인들의 관심이 높아지면서 해외를 중심으로 시장이 형성되는 단계이다. 본 논문의 결과물은 실환경에 설치되어 검증을 수행하였으며 실시간 요금제를 가정하여 에너지 절감 효과를 분석하였다.

태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템 (The Monitoring System with PV Module-level Fault Diagnosis Algorithm)

  • 고석환;소정훈;황혜미;주영철;송형준;신우균;강기환;최정내;강인철
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.21-28
    • /
    • 2018
  • The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

태양광 발전시스템 효율향상을 위한 스마트 모니터링 시스템 (Smart Monitoring System to Improve Solar Power System Efficiency)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권1호
    • /
    • pp.219-224
    • /
    • 2019
  • 국내 소규모(50kW 이하)를 포함한 태양광발전 설치 업체의 급격한 증가에 따른 발전 설치양은 증가하고 있으나 이에 대한 효율적 운영체계 및 관리가 미흡한 상황이다. 따라서 발전단가의 증가를 초래하는 부가적인 기능 보다는 현 상태에서 발전량을 최대화시키기 위한 유지보수 관리측면으로 새로운 형태의 운영체계가 필요하다. 본 논문에서는 태양광 발전소의 운영효율 극대화를 위해 Big Data와 센서 네트워크를 활용하며 전문가 시스템의 분석을 통해 발전량 예측기술, 모듈 단위 고장검출 기술개발, 인버터 구성요소의 수명 예지 및 Report 기술, 유지보수 최적화 알고리즘 및 경제성 분석 개발 등 태양광 발전소의 최적 운용이 가능하도록 하는 스마트 모니터링 시스템 개발에 목적을 두고 있다.

AFNIS를 이용한 SynRM의 최대토크 제어 (Maximum Torque Control of SynRM using AFNIS(Adaptive Fuzzy Neuro Inference))

  • 정병진;고재섭;최정식;정철호;김도연;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.219-220
    • /
    • 2008
  • The paper is proposed maximum torque control of SynRM drive using adaptive fuzzy neuro inference system(AFNIS) and artificial neural network(ANN). The control method is applicable over the entire speed range and considered the limits of the inverter's current and voltage rated value. For each control mode, a condition that determines the optimal d-axis current $i_d$ for maximum torque operation is derived. The proposed control algorithm is applied to SynRM drive system controlled AFNIS and ANN controller, the operating characteristics controlled by maximum torque control are examined in detail. Also, this paper is proposed the analysis results to verify the effectiveness of the AFNIS and ANN controller.