• Title/Summary/Keyword: inverter air conditioner

Search Result 61, Processing Time 0.023 seconds

A Study on Harmonic Correction of Air-Conditioner Power Conversion Equipment (에어컨 전력변환장치의 고조파 개선에 관한 연구)

  • Mun, Sang-Pil;Suh, Ki-Young;Lee, Hyun-Woo;Jung, Sang-Hwa
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.5
    • /
    • pp.43-50
    • /
    • 2002
  • To improve the current waveform of diode rectifiers, we propose a new operating principle for the voltage -doubler diode rectifiers. In the conventional voltage-doubler rectifier circuit, relatively large capacitors are used to boost the output voltage, while the proposed circuit uses smaller ones and a small reactor not to boost the output voltage but improve the input current waveform. A high input power factor of 97[%] and an efficiency of 98[%] are also obtained. The harmonic guide lines of proposed rectifier is no interfered with inverter switching, resulting in a simple, reliable and low-cost ac-to dc converters in comparison with the boost-type current-improving circuits.It compared conventional pulse-widthmodulated(PWM)inverter with half pulse-widthmodulated (HPWM) inverter. Proposed HPWM inverter eliminated dead-time by lowering switchingloss and holding over-shooting.

Maximum Torque Control of PMSM Drive in Field weakening Region (약계자 영역에서 PMSM 드라이브의 최대 토크제어)

  • 이홍균;이정철;김종관;정동화
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.44-49
    • /
    • 2003
  • Permanent magnet synchronous motor(PMSM) is widely used in many applications such as an electric vehicle. compressor drives of air conditioner and machine tool spindle drives. PMSM drive system have become a popular choice in various application, due to their excellent power to weight ratio. This paper is proposed maximum torque control for field weakening operation of PMSM drive. At low speeds, the reluctance torque is used to maximize the output for a given current level. This is achieved maximum torque per ampere(MTPA) by selecting an optimal value of the direct stator current component. At high speeds, the system reaches a point at which the inverter will not be able to supply the desired voltage. In this case it is necessary to make use of an increased value the direct current component. The proposed control algorithm is applied to PMSM drive system, the operating characteristics controlled by maximum torque control are examined in detail by simulation.

Synchronous control PWM Method for Reducing Common-Mode Noise in Dual Inverter Air-conditioner (복수의 인버터를 가지는 공조 시스템 모터의 Common Mode 노이즈 저감을 위한 연동제어 PWM 생성 방법)

  • Baek, Young-Jin;Park, Gwi-Geun;Park, Dong-Min;Kwon, Woo-Hyen;Kim, Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.390-391
    • /
    • 2018
  • 본 논문은 직류단 전원을 공유하는 복수의 인버터로 구성된 시스템에서 EMI 저감을 위한 연동제어 PWM 생성 기법을 제안한다. PWM 제어에 의한 스위칭시 전력단 중성점에서 커먼모드 전압이 생성되고, 기생 캐패시터를 통해 전원라인으로 유입되어 EMI 노이즈가 발생된다. 복수의 인버터 시스템에서도 동일한 현상이 나타나고, 이로인한 불특정한 커먼모드 전류가 발생한다. 본 논문에서는 2개의 인버터를 PWM 시점의 동기제어를 통해 커먼모드 노이즈를 상쇄하고자한다. 제안한 제어 기법을 검증하기 위하여 시뮬레이션으로 분석하며, 간이 실험 통해 검증한다.

  • PDF

A study on the Modulated Scroll Compressor by Bypass Method (바이패스방식을 이용한 용량가변 스크롤 압축기에 관한 연구)

  • Kim, Cheol-Hwan;Shin, Dong-Koo;Park, Hong-Hee
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.693-696
    • /
    • 2003
  • Hermetic Compressor circulates refrigerant with constant flow rate regardless of operation condition. so, at the operating condition requiring low cooling capacity, too much refrigerant flow deteriorates seasonal energy efficiency ratio(SEER). In this reason, modulated compressor is needed to improve SEER. Among many types of modulated compressor, non-inverter type modulated compressor is required for its low cost and easy to development. In the modulated scroll compressor by bypass method, EER steeply decreases for many loss like re-compression, changes of volume ratio, decrease of motor efficiency by torque variation. So. the range of modulation ratio for optimized SEER must be selected accompany with air conditioner set development.

  • PDF

Design of the Circuit for a Power Factor Correction using the Two-Input Current Resonant (2분할 전류유입 공진 회로를 이용한 PFC회로의 설계)

  • Jang, W.S.;Koh, K.H.;Seo, K.Y.;Lee, H.W.;Kwak, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.233-235
    • /
    • 2001
  • On the active filter converter for power factor correction is used inverter for a air-conditioner's power supply to meet IEC standard In the active filter topology for power factor correction, extra switch only control the input current indirectly to satisfied with the IEC standard for reducing the cost and size. In this paper, by dividing the input current into two different modes, the current conduction period can be widened and harmonics can largely be canceled between the two modes. Hence, the harmonics characteristics can be significantly improved, whereby the lower order harmonics, such as the fifth and seventh orders, are much reduced. The results are confirmed by theoretical and experimental implementations.

  • PDF

A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room (병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구)

  • Hwang, L.H.;Na, S.K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.360-369
    • /
    • 2008
  • The solar cells should be operated at the maximum power point because its output characteristics were greatly fluctuated on the variation of insolation, temperature and load. It is necessary to install an inverter among electric power converts by means of the output power of solar cell is DC. The inverter is operated supply a sinusoidal current and voltage to the load and the interactive utility line. In this paper, the proposes a photovoltaic system is designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper is operated in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature for solar cell has typical dropping character. The single phase PWM voltage source inverter is consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be develop continuously by connecting with the source of electric power for ordinary using. It can be cause the efect of saving electric power, from 10 to 20%. The single phase PWM voltage source inverter operates in situation, that its output voltage is in same phase with the utility voltage. The inverter are supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

Detection Technique and Device of Series Arcing Phenomena (직렬아크현상의 검출기술 및 장치)

  • Ji, Hong-Keun;Jung, Kwang-Suk;Park, Dae-Won;Kil, Gyung-Suk;Seo, Dong-Hoan;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.332-338
    • /
    • 2010
  • Annually, electrical fires caused by arcing phenomena in power system rapidly increase as the use of more electric appliances, but there is no established method for the prevention of the accidents. With this background, this paper dealt with the experimental results on a series arc detection technique and a device for air conditioners. Series arcing phenomena that is generated in incomplete connection of air conditioners was simulated, and the frequency spectrum was analyzed. The Fast Fourier Transform (FFT) of the arc pulse showed that the dominant frequency components exist in ranges of 190 kHz~250 kHz and 900 kHz~1.6 MHz. An arc detection circuit with low cut off frequency of 170 kHz to attenuate 60 Hz by 170 dB and a signal discriminator were designed. Also, an algorithm which separate series arc signal from unwanted noises produced by switching operation, inverter, and surge was proposed. Application experiment was carried out on several types of air-conditioners by using the arc generator specified in UL1699, and the results showed the over 99 % accuracy.

Study on the Performance Characteristics of the Roof Mounted Electrical Air Conditioning System Using Inverter Scroll Compressor (인버터 스크롤 압축기를 적용한 루프형 전동공조시스템의 냉방성능특성에 관한 연구)

  • Lee, Moo-Yeon;Won, Jong-Phil;Lee, Dong-Yeon;Cho, Chung-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4308-4313
    • /
    • 2011
  • The objective of this study is to investigate the cooling performance of the roof mounted air-conditioning system using electric driven scroll compressor for zero emission vehicles. This air conditioner with air source was used R-134a as a refrigerant and tested under various operating conditions such as refrigerant charge amount and indoor temperature, and compressor frequencies. Experimental results revealed that at all tested compressor frequencies, heat transfer rate of the evaporator increased and the cooling COP increased with the indoor temperature. In addition, the heat transfer rate of the evaporator was over 25.0kW sufficient for the cooling loads of an electric bus.

A Study Interior Noise Reduction of a Maglev Train at Low Speed (저속 주행시 자기부상열차의 실내소음저감에 관한 연구)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.7
    • /
    • pp.253-260
    • /
    • 2001
  • A Study of interior noise reduction in the magelv train is presented. Tarin speed of interest is low such that aero-dynamic noise is negligible and power supply system is a dominant noise source. Based on the measurements of interior noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources are investigated several noise reducing methods are studied such as STL increasement of floor panels. sealing. and absorption treatment It is found that the most important noise sources are VVVF inverter and SLM in running condition, whereas air conditioner and DC/DC converter are dominant in zero speed. Sine the major noise sources are under the floor complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction After sound absorbing material, which is polyurethan foam of 50 mm thickness, is thickness, is attached to the downward side of the floor in addition to sealing treatment, the interior noise is reduced by 3~4 dB.

  • PDF

Analysis of noise source for refrigerant-induced noise in suction and discharge piping systems of compressor installed in air conditioner outdoor unit using wavenumber-frequency decomposition technique (파수-주파수 분리 기법을 통한 에어컨 실외기 압축기 흡배기 배관계 냉매 유발 소음원 분석)

  • Sangjun Park;Sangheon Lee;Cheolung Cheong;Jinhyung Park;Jangwoo Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.5
    • /
    • pp.570-583
    • /
    • 2024
  • The supply of inverter-type air conditioners for cooling in summer and heating in winter is increasing. In addition, since the operating speed of the compressor has been continuously increased for higher efficiency and higher performance, the flow speed of the refrigerant has also increased. As a result, it results in the increase of the relative contribution of flow-born noise to total noise generated from outdoor unit, and this highlights the importance of designing for the noise reduction to addressing flow-borne noise and requires necessary to analyze noise generation mechanisms by flow borne noise. Therefore, in this paper, the noise generation mechanisms by flow borne noise from air conditioner outdoor unit was numerically investigated. The wall pressure field was predicted using Large Eddy Simulation(LES) for the refrigerant flow inside the pipe, and the vibration and radiated noise were predicted using structure and acoustic coupled scheme based Finite Element Method (FEM). In this step, the compressible/in-compressible pressure field were separated using Wavenumber-Frequency Analysis(WFA) for inner pipe wall, and this results were used in analyzing the noise source due to refrigerant flow.