• Title/Summary/Keyword: inverter air conditioner

Search Result 61, Processing Time 0.026 seconds

An Experimental Study on the Performance Improvement of an R32 Inverter Heat Pump System (R32 인버터 히트펌프 시스템의 성능향상에 관한 실험적 연구)

  • Park, Yun Ki;Ha, Man Yeoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.547-552
    • /
    • 2014
  • As global warming in recent years has raised ever more critical concern, refrigerants with high global warming potentials (GWP) are facing the challenge of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioning and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. The present study presents experimental results of an inverter heat pump system that uses R32 as an alternative refrigerant to R410A. Drop-in tests with R32 indicated that the energy efficiency ratio of the system increased by 5.3% in cooling standard mode, and by 4.2% in heating standard mode at the same capacity; and that the cooling and heating capacity increased by about 12% at the same compressor operating frequency, while the annual performance factor (APF) of the system increased by 5.3%.

The Design of Fuse in High Efficient Inverter Control System using Ceramic Radiant Heat and Metal Film Laminated Plating (세라믹 방열과 박막 적층 도금을 이용한 고효율 인버터 제어 회로용 퓨즈 설계)

  • Kim, Eun-Min;Kim, Shin-Hyo;Cho, Dae-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1538-1544
    • /
    • 2014
  • In recent years, The electronic and energy industries demand low power consumption and high efficiency, so under their demands, the white goods industries which are represented for refrigerator and air conditioner system be implemented energy-saving power suppling structure with inverter control system. As inverter control system is different from step control type, when switching system is optimizing temperature control during short period, the inrush plus current can be flown in the circuit. In despite of these characteristics, there is no fuse which can be applied to this type until now. For this reason, we suggest the method of manufacturing protector in the high efficient inverter control system using the alumina-based ceramic radiated heat characteristics and metal films laminated plating. And through the evaluating electrical characteristics, we make a possible to utilize the method when designing overall fuses.

Development of Performance Evaluation and Control System of Multi-Air Conditioner (멀티에어컨의 성능평가 및 제어시스템 개발에 대한 연구)

  • Lee H.W.;Ko K.W.;Gwon Yeong-Cheol;Lee J.H.;Lee Y.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1107-1114
    • /
    • 2005
  • The running condition of multi-system air conditioner is prone to vary largely as it is designed for individual conditioning in each space of middle and small sized buildings. This leads to overcooling in case of partial load run, while the lack of capacity happens in case of full load run. Besides these, there exist such problems as instabilities due to the uneven refrigerant distribution caused by fluctuation of load and the change in piping line. Based upon the basic study on the function characteristics found in parts needed for maximized system working design in order to troubleshoot, the system functioning pattern should be identified through the different tests with various operating circumstances and the analysis models should be developed. With this ground, the control logic has to be made to have a control over capacity and make possible the efficient distribution of refrigerant.

  • PDF

The Design of Low-Cost Vector-Controlled Inverter for Induction Motor Using ARM Cortex-M4 Microcontroller (ARM Cortex-M4 마이크로컨트롤러를 사용한 유도전동기의 저가형 벡터제어 인버터 설계)

  • Kim, Dong-Ki;Yoon, Duck-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.816-821
    • /
    • 2013
  • This paper proposes the design method of low-cost vector control system for induction motor using the ARM Cortex-M4 microcontroller. This MCU can be used instead of expensive DSP to control the home appliances such as refrigerator, air conditioner, washing machine and so on. This paper explains the major features of Cortex-M4 for motor control and how to realize a vector-controlled inverter using it. The developed system is applied to 3-phase induction motor of 200[W] and experimental results show good performance similar to the system using TMS320F28335 DSP.

EMI Characteristics and filter design of AC Drives for Home Appliances (가전기기용 교류 전동기 구동 시스템의 EMI 특성 및 필터 설계)

  • 정세교;신휘범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.81-87
    • /
    • 2004
  • This paper describes a design method of electromagnetic interference (EMI) filter for pulse-width modulation (PWM) inverter-fed AC drives used for home appliances such as washing machine and air conditioner. The generating and coupling mechanisms of the conducted EMI for AC drives are first investigated. The design procedure of the EMI filter based on the EMI separation principle is then presented. Experiments we carried out for the PWM inverter-fed induction motor drive system and it is shown that the results satisfy the EN55014 EMI regulation.

Development of Static Inverter for the Tilting Train express TTX (틸팅 차량용 보조전원장치의 개발)

  • Lee, Chang-Hee;Kim, Hyung-Cheol;Song, Young-Shin;Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1537-1539
    • /
    • 2005
  • This paper proposes 210[kVA] rated SIV(Static Inverter) system for the TTX(Tilting Train eXpress). The SIV provides power of a fluorescent light in the car, Air-conditioner, and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The performance of SIV system will be verified by simulation and experimental results.

  • PDF

Power-factor improvement of residential solar air-conditioner power system (가정용 태양광 에어컨 전원시스템의 역률 개선)

  • Park, Y.J.;Mun, S.P.;Park, J.W.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.6-8
    • /
    • 2002
  • Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can degrade the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problems in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. A high input power factor of 97[%] and an efficiency of 98[%] are also obtained. The harmonic guide lines of proposed rectifier is no interfered with inverter switching, resulting in a simple, reliable and low cost ac to dc converters in comparison with the boost type current improving circuits.

  • PDF

A Study on the Input Power Factor Correction & THD Reduction of Inverter Airconditioner (인버터 에어컨의 입력 역률 개선 및 하모닉 저감에 관한 연구)

  • Kim, Seong-Hwan;Lee, In-Ho;Yoo, Ji-Yoon;Kim, Tae-Duk;Rae, Young-Dawn;Park, Yoon-Ser
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.235-237
    • /
    • 1995
  • The demands of minimizing the reactive power and reducing. the current harmonics are increasing nowadays. The inverter airconditioner needs high power and it operates with wide load range. Conventionally, ah huge LC passive filter is used in airconditioner to improve the P.F and to reduce current harmonics which doesn't gives good results. In this paper, a design of active power factor correction(PFC) circuit for inverter air conditioner is described. To improve the P.F and to reduce the THD, an average current controlled active PFC is designed and tested. Experimental results show that the developed system achieves almost unity P.F and low THD for all load range.

  • PDF

A study on Photovoltaic System to Considers a Solar Position Tracker for Air Conditioner a Clinic room (병실 냉.난방장치용 태양 위치 추적기를 이용한 태양광 발전시스템에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1355-1362
    • /
    • 2007
  • In this paper, these setting can be useful in the microprocessor and sensor that designed to improve the efficiency of the photovoltaic system the photovoltaic position tracker device, and compared the normal photovoltaic system of fixed form with the photovoltaic system of solar position tracked form. Moreover, this is compared the catalogue of solar cell module and the simulation through a mathematics modelling with the solar cell's characteristic interpreting and that is composed an power conversion system with boost converter and voltage source inverter. This device can be used to the constant voltage control method for maximum power point tracking in boost converter control. Experiment Results is shown that using a SPWM(Sinusoidal Pulse Width Modulation) control method in inverter control.

  • PDF

A Study of the Dynamic Performance Improvement of a Linear Compressor Stroke Controller with a Current Control Loop (전류제어 루프를 갖는 선형 압축기 스트로크 제어기의 동적 성능 향상에 관한 연구)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.274-282
    • /
    • 2013
  • In this paper, a linear motor stroke controller using a phase lag filter and a single phase PWM inverter with a current controller has been implemented. In order to control the cooling capability of a refrigerator or an air conditioner in which linear compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. Generally, the frequency is fixed, for example, as 60Hz and the stroke is adjusted. The dynamic performance of linear compressors depends on how accurately the stroke or the piston position is controlled by the current applied. A linear motor piston position controller with a current control loop is proposed and verified via some simulation studies.