A Study on the Characteristics of Internal Dynamic Pressure of Vane Pump (베인 펌프의 내부 비정상 압력특성에 관한 연구)

  • 정석훈;정재연
    • Tribology and Lubricants
    • /
    • v.14 no.1
    • /
    • pp.79-84
    • /
    • 1998
  • This paper presents the experimental study of the dynamic internal pressure within a vane pump. The measurement of the dynamic internal pressure acting on the line contact between the vane and the camring in a vane pump with intravanes have been investigated. The variations of the radial acting force of a vane are calculated from previously measured results of dynamic internal pressure in four chambers surrounding a vane, and the variations of the film thickness are estimated in both the rotational speed ranges from 600 to 1200 rpm and the delivery pressure ranges from 1 to 14 MPa. The experimental technic has been established to obtain the data for performance analysis, such as reaction forces between vane and camring, friction wear at the contact regions, leakage characteristics and net forces upon the pump shaft in case of the unsteady load which is forced to the intravane pressure balance type vane pump.

Tne Measurements of internal Dynamic Pressure for Development of a High Performance Oil hydraulic Vane Pump(I) (고성능 유압 베인펌프 개발을 위한 내부 변동압력 측정 (I))

  • 정재연;정석훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.191-199
    • /
    • 1992
  • This paper presents in experimental study of the dynamic internal pressure within an oil hydraulic vane pump. The measurements of the dynamic internal pressures near the vane of a pressure balance type of an oil hydraulic vane pump with intravanes has been made to provide the essential information for the study of the pump dynamics and control, the pump design and the analysis of tribological problems in the sliding components. The influences of the discharge pressure and rotating speed of the vane on the dynamic pressure in four chambers surrounding a vane have been investigated. The results indicate that the surge pressures of the chambers at the instant moment of discharge and closure are affected by the rotating speed. The pressure in the intravane chamber maintains almost constant values, which remarkably effects the pulsating discharge pressure.

A Study on the Acting Load in the Vane Tip of Vane Pump for Design (베인펌프 설계를 위한 베인 선단부의 작용력에 관한 연구)

  • 정석훈
    • Tribology and Lubricants
    • /
    • v.19 no.6
    • /
    • pp.370-375
    • /
    • 2003
  • The radial acting load of vane on the camring in oil hydraulic vane pumps with and without intra­vanes have been investigated. The influences of the discharge pressure and rotating speed of the vane to the load were discussed. The variations of the radial acting load of a vane were calculated on the basis of the results measured for the dynamic internal pressure in the four chambers surrounding a vane. It provides essential information for the study of pump dynamics and control, the pump design and the analysis of tribological problems in the sliding components.