• Title/Summary/Keyword: interventional radiology

Search Result 225, Processing Time 0.024 seconds

Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations

  • Keun Young Park;Jin Woo Kim;Byung Moon Kim;Dong Joon Kim;Joonho Chung;Chang Ki Jang;Jun-Hwee Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1285-1292
    • /
    • 2019
  • Objective: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. Materials and Methods: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. Results: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). Conclusion: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.

Percutaneous Placement of Self-expandable Metallic Biliary Stents in Malignant Extrahepatic Strictures: Indications of Transpapillary and Suprapapillary Methods

  • Deok Hee Lee;Jeong-Sik Yu;Jae Cheol Hwang;Ki Hwang Kim
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • Objective: To compare the efficacy of suprapapillary and transpapillary methods of transhepatic biliary metallic stent placement in malignant biliary strictures and to specify the indications of each method applied. Materials and Methods: Stents were placed in 59 patients. Strictures were categorized as type A (within 3 cm of the ampulla, n = 27), type B (over 3 cm from ampulla, n = 7), type C (within 3 cm of the bending portion, n = 9), or type D (over 3 cm above the bending portion, n=16). The stenting method was suprapapillary in 34 cases and transpapillary in 25. The rates of initial and long-term patency and of early recurrence were compared. Results: Initial patency rates for the suprapapillary and transpapillary methods were 1/7 (14.3%) and 20/20 (100%) respectively for type A (p < 0.0001), 4/5 (80.0%) and 2/2 for type B, 3/7 (42.9%) and 2/2 for type C, and 15/16 (93.8%) and 0/0 for type D. Early recurrence rates were 7/30 (23.3%) using the suprapapillary method and 4/29 (13.8%) using the transpapillary method (p = 0.51). The long-term patency rate did not differ significantly according to either type (p = 0.37) or method (p = 0.62). Conclusion: For good initial patency, the transpapillary method is recommended for strictures of the distal extrahepatic duct near the ampulla and just above the bending portion. Long-term patency is not influenced by the stenting method employed.

  • PDF

Development of Biodegradable Polymeric Membrane for Interventional Procedure: Preliminary Study (인터벤션 시술을 위한 생분해성 고분자막의 개발 : 예비연구)

  • Bang, Jung-Wan;Hyun, Chang-Yong;Kim, Tae-Hyung;So, Woon-Young;Kim, Jin-Tae;Kim, Sang-Sub;Jung, Hee Dong;Heo, Yeong Cheol
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • This study was to evaluate clinical feasibility of biodegradable polymeric membrane for interventional procedure in preliminary study. Bio-degradable polymetric membrane was produced into a solution by mixing hyaluronic acid powder with NaOH solution in a heating mantle. Three different concentrations of contrast media (10, 20, and 30 vol%) were added to the produced soluble powder, and vertical agitation was performed for 12 hours at a speed of 100 to 200 rpm at a room temperature. It was freeze dried for 24 hours at a temperature $80^{\circ}C$. Pressure on the freeze dried sample was exerted by a hydraulic press in order to form the freeze dried sample into a membrane. The membrane produced with varying contrast medium concentration was visually examined by a scanning electron microscope and radiographically inspected. Under the visual examination, the higher the concentration of contrast medium, the rougher the surface. Radiographic transparency was similar under all conditions of fluoroscopic radiography, simple radiography, and serial radiography. In conclusion, this preliminary study verified that bio-degradable membrane produced with hyaluronic acid was a material with clinical usability.

First-Pass Recanalization with EmboTrap II in Acute Ischemic Stroke (FREE-AIS): A Multicenter Prospective Study

  • Jang-Hyun Baek;Byung Moon Kim;Sang Hyun Suh;Hong-Jun Jeon;Eun Hyun Ihm;Hyungjong Park;Chang-Hyun Kim;Sang-Hoon Cha;Chi-Hoon Choi;Kyung Sik Yi;Jun-Hwee Kim;Sangil Suh;Byungjun Kim;Yoonkyung Chang;So Yeon Kim;Jae Sang Oh;Ji Hoe Heo;Dong Joon Kim;Hyo Suk Nam;Young Dae Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.2
    • /
    • pp.145-154
    • /
    • 2023
  • Objective: We aimed to evaluate the efficacy of EmboTrap II in terms of first-pass recanalization and to determine whether it could yield favorable outcomes. Materials and Methods: In this multicenter, prospective study, we consecutively enrolled patients who underwent mechanical thrombectomy using EmboTrap II as a front-line device. The primary outcome was the first pass effect (FPE) rate defined by modified Thrombolysis In Cerebral Infarction (mTICI) grade 2c or 3 by the first pass of EmboTrap II. In addition, modified FPE (mFPE; mTICI grade 2b-3 by the first pass of EmboTrap II), successful recanalization (final mTICI grade 2b-3), and clinical outcomes were assessed. We also analyzed the effect of FPE on a modified Rankin Scale (mRS) score of 0-2 at 3 months. Results: Two hundred-ten patients (mean age ± standard deviation, 73.3 ± 11.4 years; male, 55.7%) were included. Ninety-nine patients (47.1%) had FPE, and mFPE was achieved in 150 (71.4%) patients. Successful recanalization was achieved in 191 (91.0%) patients. Among them, 164 (85.9%) patients underwent successful recanalization by exclusively using EmboTrap II. The time from groin puncture to FPE was 25.0 minutes (interquartile range, 17.0-35.0 minutes). Procedure-related complications were observed in seven (3.3%) patients. Symptomatic intracranial hemorrhage developed in 14 (6.7%) patients. One hundred twenty-three (58.9% of 209 completely followed) patients had an mRS score of 0-2. Sixteen (7.7% of 209) patients died during the follow-up period. Patients who had successful recanalization with FPE were four times more likely to have an mRS score of 0-2 than those who had successful recanalization without FPE (adjusted odds ratio, 4.13; 95% confidence interval, 1.59-10.8; p = 0.004). Conclusion: Mechanical thrombectomy using the front-line EmboTrap II is effective and safe. In particular, FPE rates were high. Achieving FPE was important for an mRS score of 0-2, even in patients with successful recanalization.

Identifying Small Bowel Gastrointestinal Stromal Tumor as the Culprit Lesion in Obscure Gastrointestinal Bleeding: Emphasis on Angiographic Findings (원인불명의 위장관 출혈을 보인 소장 위장관 기질종양 식별: 혈관조영술 소견의 강조)

  • Hyung In Choi;Min Jeong Choi;Bong Man Kim;Hwan Namgung;Seung Kyu Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.400-405
    • /
    • 2022
  • Gastrointestinal stromal tumors (GISTs) are not uncommon and often cause gastrointestinal bleeding. GISTs occurring in the small intestine are occasionally difficult to identify by endoscopy and CT. In this case, the patient underwent CT three times before surgery, and the lesion was found to be located in a different area of the abdominal cavity on each CT scan. Moreover, the lesion was missed in the first two CT images because it was difficult to distinguish it from the nearby collapsed small intestine. The lesion was eventually detected through angiography; however, the correct diagnosis and treatment were delayed for 3 years because it was mistaken for a vascular malformation, which is the most common cause of obscure GI bleeding in elderly patients. This report emphasizes the need for interventional radiologists to be updated and vigilant of the angiographic features of GISTs to make an accurate diagnosis and establish a management strategy.

Current Strategy in Endovascular Management for Below-the-Knee Arterial Lesions (무릎 밑 동맥의 혈관 내 치료의 최신 지견)

  • Kyosoo Hwang;Sang Woo Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.541-550
    • /
    • 2021
  • The below-the-knee arterial tree is the thinnest of all the leg vessels and is an important path for blood flow to the foot. Hence, lesions including stenosis, especially obstruction, may lead to critical limb ischemia which represents the most severe clinical manifestation of peripheral arterial disease. It is characterized by the presence of ischemic rest pain, ischemic lesions, or gangrene attributable to the objectively proven arterial occlusive disease. Typically, the atherosclerotic disease process involving the below-the-knee arterial tree is diffuse in the majority of patients. The cornerstone of therapy is vascular reconstruction and limb salvage. Revascularization should be attempted whenever technically possible, without delay, in patients presenting critical limb ischemia and when the clinical status is not hopelessly non-ambulatory. Therefore, endovascular treatment can become the gold standard for the full range of patients including below-the-knee, limiting the clinical role of the classically trained surgeons.

Interventional Treatment of Chemical Pleuritis and Hemothorax Caused by Iatrogenic Internal Jugular Vein Perforation after Central Venous Port System Implantation: A Case Report (중심정맥포트 삽입 후 의인성 속목정맥 천공에 의한 화학적 늑막염과 혈흉의 중재적 치료: 증례 보고)

  • Do Woo Kim;Young Hwan Kim;Ung Rae Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1459-1465
    • /
    • 2020
  • The perforation of the intrathoracic internal jugular vein during the placement of an implantable central venous chemoport is a rare complication that is manifested by hemothorax or hemorrhagic shock. Furthermore, inappropriate instillation of a chemotherapeutic agent in the chemoport can cause chemical pleuritis, and the diagnosis of these complications prior to the instillation of chemotherapeutic agents and open thoracic surgery is mandatory. We report a patient with chemical pleuritis and hemothorax following an inappropriate instillation of a chemotherapeutic agent, through the perforated right internal jugular vein after placement of an implantable central venous chemoport. Treatment by embolization using coils and N-butyl cyanoacrylate, after percutaneous drainage, was successful.

Current Practices in Breast Magnetic Resonance Imaging: a Survey Involving the Korean Society of Breast Imaging

  • Yun, Bo La;Kim, Sun Mi;Jang, Mijung;Kang, Bong Joo;Cho, Nariya;Kim, Sung Hun;Koo, Hye Ryoung;Chae, Eun Young;Ko, Eun Sook;Han, Boo-Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.233-241
    • /
    • 2017
  • Purpose: To report on the current practices in breast magnetic resonance imaging (MRI) in Korea. Materials and Methods: We invited the 68 members of the Korean Society of Breast Imaging who were working in hospitals with available breast MRI to participate in a survey on how they performed and interpreted breast MRI. We asked one member from each hospital to respond to the survey. A total of 22 surveys from 22 hospitals were analyzed. Results: Out of 22 hospitals, 13 (59.1%) performed at least 300 breast MRI examinations per year, and 5 out of 22 (22.7%) performed > 1200 per year. Out of 31 machines, 14 (45.2%) machines were 1.5-T scanners and 17 (54.8%) were 3.0-T scanners. All hospitals did contrast-enhanced breast MRI. Full-time breast radiologists supervised the performance and interpreted breast MRI in 19 of 22 (86.4%) of hospitals. All hospitals used BI-RADS for MRI interpretation. For computer-aided detection (CAD), 13 (59.1%) hospitals sometimes or always use it and 9 (40.9%) hospitals did not use CAD. Two (9.1%) and twelve (54.5%) hospitals never and rarely interpreted breast MRI without correlating the mammography or ultrasound, respectively. The majority of respondents rarely (13/21, 61.9%) or never (5/21, 23.8%) interpreted breast MRI performed at an outside facility. Of the hospitals performing contrast-enhanced examinations, 15 of 22 (68.2%) did not perform MRI-guided interventional procedures. Conclusion: Breast MRI is extensively performed in Korea. The indication and practical patterns are diverse. The information from this survey would provide the basis for the development of Korean breast MRI practice guidelines.

Traumatic Hemothorax Caused by Thoracic Wall and Intrathoracic Injuries: Clinical Outcomes of Transcatheter Systemic Artery Embolization (흉벽 및 흉곽 내 장기 손상으로 인한 외상성 혈흉: 전신 동맥 색전술의 임상 결과)

  • Chang Mu Lee;Chang Ho Jeon;Rang Lee;Hoon Kwon;Chang Won Kim;Jin Hyeok Kim;Jae Hun Kim;Hohyun Kim;Seon Hee Kim;Chan Kyu Lee;Chan Yong Park;Miju Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.923-935
    • /
    • 2021
  • Purpose We aimed to assess the clinical efficacy of transcatheter arterial embolization (TAE) for treating hemothorax caused by chest trauma. Materials and Methods Between 2015 and 2019, 68 patients (56 male; mean age, 58.2 years) were transferred to our interventional unit for selective TAE to treat thoracic bleeding. We retrospectively investigated their demographics, angiographic findings, embolization techniques, technical and clinical success rates, and complications. Results Bleeding occurred mostly from the intercostal arteries (50%) and the internal mammary arteries (29.5%). Except one patient, TAE achieved technical success, defined as the immediate cessation of bleeding, in all the other patients. Four patients successfully underwent repeated TAE for delayed bleeding or increasing hematoma after the initial TAE. The clinical success rate, defined as no need for thoracotomy for hemostasis after TAE, was 92.6%. Five patients underwent post-embolization thoracotomy for hemostasis. No patient developed major TAE-related complications, such as cerebral infarction or quadriplegia. Conclusion TAE is a safe, effective and minimally invasive method for controlling thoracic wall and intrathoracic systemic arterial hemorrhage after thoracic trauma. TAE may be considered for patients with hemothorax without other concomitant injuries which require emergency surgery, or those who undergoing emergency TAE for abdominal or pelvic hemostasis.

Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea (심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가)

  • Kim, Jung-Su;Lee, Joun-Hyuk;Jung, Hae-Kyoung;Kim, Jung-Min;Cho, Byung Ryul
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • The use of cardiac angiography (CA) and the interventional procedures is rapidly increasing due to the increase in modern adult diseases. Cardiovascular intervention (CI) is an examination method where radiation is applied to the same area for a long period, and thus may cause skin injury. In this study, we investigate the diagnostic reference level (DRL) of the cardiovascular intervention (CI) carried out by medical institutions and use it as a tool to reduce patient exposure dose. In this study, the DRL was set by acquiring information about the cumulative fluoroscopy time, cumulative fluoroscopy dose-area product (DAP), radiography DAP, cumulative DAP, air kerma, number of video clips, and the total number of images from the cardiac angiography and interventional procedures performed on 147 patients. The DAPs corresponding to the DRL of cardiac angiography(CA) and that of the interventional procedures were shown to be $44.4Gy{\cdot}cm2$ and $298.6Gy{\cdot}cm2$, respectively; the corresponding DRLs of fluoroscopy time were shown to be 191.5s and 1935.3s, respectively. A DRL is not a strict upper bound for radiation exposure. However, the process of setting, enacting, and reviewing the DRLs for the dose by medical institutions will contribute to a reduction in the unnecessary exposure dose of patients.