• Title/Summary/Keyword: interventional radiology

Search Result 225, Processing Time 0.029 seconds

Sclerotherapy of Peritoneal Inclusion Cysts: Preliminary Results in Seven Patients

  • Jun Yong Jeong;Seung Hyup Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.164-170
    • /
    • 2001
  • Objective: To evaluate the technical feasibility and the clinical effectiveness of sclerotherapy for the treatment of peritoneal inclusion cysts (PICs). Materials and Methods: Between June 1996 and February 2001, eight PICs in seven female patients aged 28-43 (mean, 36) years were instilled with sclerosant (povidone-iodine in three, ethanol in three, both povidone-iodine and ethanol in one). All seven patients subsequently experienced less abdominal pain. After drainage via an 8.5-Fr pigtail catheter inserted in the PICs (transabdominally in six cases, transvaginally in one), sclerosant equivalent in volume to about one-third that of drained fluid was introduced daily until the drained volume was less than 5ml. Follow-up by means of clinical procedures and ultrasound was performed every three months, at which time the success rate, possible complications and recurrence were determined. Results: Sclerotherapy was technically successful in all seven patients, though immediately after the procedure, minor complications were noted in three patients (mild pain in two, mild fever in one). During the follow-up of 4-60 (mean, 24.7) months, sclerotherapy proved successful and without long-term complications in all seven patients: lower abdominal pain disappeared and the diameter of the cysts decreased more than 50%, with complete regression in four cases. During the follow-up period there was no recurrence. Conclusion: Sclerotherapy following catheter insertion is technically feasible and effective for the treatment of PICs.

  • PDF

A Pictorial Review of Radiologic Findings of Foreign Bodies in the Thorax (흉부 이물의 영상의학적 소견 )

  • Hee Soo Won;Yoon Ki Cha;Jeung Sook Kim;Seo Jin Jang;So Hyeon Bak;Hyun Jung Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.293-303
    • /
    • 2022
  • Thoracic foreign bodies (FBs) are serious and relatively frequent in emergency departments. Thoracic FBs may occur in association with aspiration, ingestion, trauma, or iatrogenic causes. Imaging plays an important role in the identification of FBs and their dimensions, structures, and locations, before the initiation of interventional treatment. To guide proper clinical management, radiologists should be aware of the radiologic presentations and the consequences of thoracic FBs. In this pictorial essay, we reviewed the optimal imaging settings to identify FBs in the thorax, classified thoracic FBs into four types according to their etiology, and reviewed the characteristic imaging features and the possible complications.

Contrecoup Injury associated with Fatal Portal Vein Bleeding: A Case Report (반충손상 기전에 의한 간문맥손상에 대한 증례 보고)

  • Joonghyun Yoo;Sung-Joon Park;Seung Hwa Lee;Hwan Hoon Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1594-1599
    • /
    • 2021
  • A 64-year-old male visited our emergency department due to severe right flank pain after falling from a 2-meter height. Contrast-enhanced CT revealed a right hemothorax with multiple fractures in the right ribs and iliac bone. A small hematoma in the right perihepatic space was noted, but there was no hepatic laceration on CT. Initial surgical management led to continuous uncontrolled bleeding around the porta hepatis, and subsequent arterial angiography could not demonstrate a bleeding focus. However, immediate follow-up CT showed contrast extravasation on the left side of abdomen, and a percutaneous transhepatic portal venogram revealed active bleeding from the left portal vein. Although the wound was embolized with a glue, the patient suffered from a cardiac arrest and finally expired. In conclusion, during evaluation of abdominal trauma patients, portal vein bleeding and contrecoup injuries should be considered when hepatic arteriography findings are unremarkable.

Isolated Gastric Varix Bleeding Caused by Splenic Vein Obstruction: Two Case Reports (비장 정맥 폐쇄로 인한 단독 위정맥류 출혈: 두 건의 증례 보고)

  • Juyoung Pak;Sangjoon Lee;Hyoung Nam Lee;Dongho Hyun;Sung-Joon Park;Youngjong Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.291-297
    • /
    • 2023
  • Isolated left-sided portal hypertension is a rare clinical syndrome caused by splenic veno-occlusive disease. Splenic vein thrombosis and extrinsic compression causes proximal splenic vein hypertension, and the splenic blood flows into the superior mesenteric or portal vein through the upper stomach's collateral vessels, such as the short gastric, coronary, and gastroepiploic veins. Open splenectomy is recommended to treat gastrointestinal bleeding caused by isolated left-sided portal hypertension. Interventional management could be a clinically useful option for selected patients who want to avoid surgical corrections. The report presents two cases of left-sided portal hypertension with gastric variceal bleeding.

131I-Labeled-Metuximab Plus Transarterial Chemoembolization in Combination Therapy for Unresectable Hepatocellular Carcinoma: Results from a Multicenter Phase IV Clinical Study

  • Ma, Jun;Wang, Jian-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7441-7447
    • /
    • 2015
  • Objective: This study evaluated the safety and objective response of combining $^{131}I$-labeled-metuximab (Licartin) with transarterial chemoembolization (TACE) in the treatment of unresectable hepatocellular carcinoma (HCC). Materials and Methods: In a multicenter open-label clinical trial, 341 enrolled patients with stage III/IV HCC according to TNM criteria were nonrandomly assigned to a trial group (n=167) and a control group (n=174), undergoing TACE following hepatic intra-arterial injection of licartin or TACE alone from July 2007 to July 2009. Radiopharmaceutical distribution was evaluated. The primary endpoint was overall survival; secondary endpoints included time-to-progression (TTP), toxicity and adverse events (AEs). Results: The radiobiological distribution demonstrated better localization of licartin in liver tumors than other tissues (P<0.01). The organ absorbed doses to liver and red marrow were $3.19{\pm}1.01Gy$ and $0.55{\pm}0.22Gy$, respectively. The 1-year survival rate was significantly higher [79.47% vs. 65.59%, hazard ratio (HR), 0.598, P=0.041] and TTP significantly improved ($6.82{\pm}1.28$ vs. $4.7{\pm}1.14months$, P=0.037) compared with the control group. Patients at stage III achieved more benefit of one year survival than stage IV in the trial group (86.9% vs. 53.8%, P<0.001). There were significant different toxicities in leukocytopenia, thrombocytopenia and increased total bilirubin level [P<0.001, P=0.013, P<0.01, relative risk (RR) 1.63, 1.33, 1.43], but no differences in severe AEs of upper GI hemorrhage and severe liver dysfunction between the groups (5.39% vs. 2.3%, P=0.136). Conclusions: Owing to excellent tumor-targeting, promised efficacy and favourable toxicity profile, the novel combination therapy of licartin and TACE could be applied in patients with unresectable HCC.

Clinical Application of an Image-Guided Intervention in Three Dogs

  • Choi, Minsik;Kwon, Dohoon;Ahn, Jisoo;Ko, Minjung;Ahn, Jiyoung;Jung, Joohyun;Kim, Hakhyun;Kang, Ji-Houn;Chang, Dongwoo
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.100-105
    • /
    • 2020
  • A 9-month-old, 11.3 kg, intact, male, mixed-breed dog was referred for treatment of cor triatriatum dexter (CTD); a 5-month-old, 1.9 kg, intact, male Maltese for pulmonic stenosis (PS); and a 3-year-old, 6.62 kg, intact, female West Highland white terrier for esophageal stricture with regurgitation. A balloon catheter intervention was performed in the dog with CTD, and subsequent color Doppler ultrasound and abdominal ultrasound showed normal blood flow across the perforated membrane dividing the right atrium and the disappearance of the severe ascites present before treatment. Balloon catheter intervention in the dog with PS reduced the blood flow through the stenosis from 5.82 m/s to 3.97 m/s. In the dog with esophageal stricture, balloon catheter intervention widened the esophagus and no subsequent regurgitation was observed. Balloon catheter intervention is an interventional radiology procedure that represents a definitive treatment option for various stenotic lesions in dogs, including CTD, PS, and esophageal stricture. Although interventional radiology procedures for these diseases have already been reported, details of procedures and successful outcome have not been reported in Korea.

A Study of Radiation Doses to the Patient and Medical Team at Embolization Procedures

  • Castilho, Alvaro Vilas Boas;Szjenfeld, Denis;Nalli, Darcio;Fornazari, Vinicius;Moreira, Antonio Carlos;Medeiros, Regina Bitelli
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.110-117
    • /
    • 2019
  • Background: This study aimed to estimate occupational doses and patient peak skin doses (PSDs) during interventional radiology procedures. Materials and Methods: We examined data from brain embolization (n = 30), hepatic chemoembolization (n = 50), and uterine embolization (n = 12). The PSDs were measured using radiochromic film around the patient's head (group 1) or abdominal/pelvic region (group 2). Acquisition technical data and kerma-area products (KAP) were also recorded. Occupational doses were measured using $Instadose^{TM}$ dosimeters near the left eye region (LER), chest, and left ankle. Results and Discussion: The third quartile (median) KAP values were $408.1(235.3)Gy{\cdot}cm^2$ for group 1 and $584.4(449.4)Gy{\cdot}cm^2$ for group 2. The average PSDs were greatest during vascular procedures, reaching 1,004.4 (786.4) mGy, and the highest PSD was 2,352.6 mGy (during hepatic chemoembolization). The third quartile (median) occupational doses were 0.35 (0.21) mSv at the LER, 0.25 (0.15) mSv at the chest, and 1.47 (0.64) mSv at the left ankle. Occupational doses at the LER were higher than at the chest, which highlights the importance of protective glasses and suspended shields. The occupational doses at the ankle region were also high, which highlights the importance of using a lead-lined curtain attached to the table. Conclusion: The results indicate that physicians can reach, for eye region, the weekly occupational dose limit after around 15 procedures, even when using proper protection. The average PSD values were below the threshold for tissue reactions, although the complexity of these procedures emphasises the importance of considering related risks.

Endoscopic ultrasound-guided intervention for inaccessible papilla in advanced malignant hilar biliary obstruction

  • Partha Pal;Sundeep Lakhtakia
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.143-154
    • /
    • 2023
  • Advanced malignant hilar biliary obstruction (MHBO) with inaccessible papilla poses a significant challenge to endoscopists, as drainage of multiple liver segments may be warranted. Transpapillary drainage may not be feasible in patients with surgically altered anatomy, duodenal stenosis, prior duodenal self-expanding metal stent, and after initial transpapillary drainage, but require re-intervention for draining separated liver segments. Endoscopic ultrasound-guided biliary drainage (EUS-BD) and percutaneous trans-hepatic biliary drainage are the feasible options in this scenario. The major advantages of EUS-BD over percutaneous trans-hepatic biliary drainage include a reduction in patient discomfort and internal drainage away from the tumor, thus reducing the possibility of tissue or tumor ingrowth. With innovations, EUS-BD is helpful not only for bilateral communicating MHBO but also for non-communicating systems with bridging hilar stents or isolated right intra-hepatic duct drainage by hepatico-duodenostomy. EUS-guided multi-stent drainage with specially designed cannulas and guidewires has become a reality. A combined approach with endoscopic retrograde cholangiopancreatography for re-intervention, interventional radiology, and intraductal tumor ablative therapies has been reported. Stent migration and bile leakage can be minimized with proper stent selection and technique, and stent blocks can be managed with EUS-guided interventions in a majority of cases. Future comparative studies are required to establish the role of EUS-guided interventions in MHBO as rescue or primary therapy.

Vitamin D Effect on Ultrasonography and Laboratory Indices and Biochemical Indicators in the Blood: an Interventional Study on 12 to 18-Year-Old Children with Fatty Liver

  • Namakin, Kokab;Hosseini, Mahya;Zardast, Mahmoud;Mohammadifard, Mahyar
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.2
    • /
    • pp.187-196
    • /
    • 2021
  • Purpose: The rising prevalence of childhood obesity in the past decades has caused non-alcoholic fatty liver disease (NAFLD) to become the most common cause of pediatric chronic liver disease worldwide. This study was aimed at determining the effect of vitamin D (Vit D) on ultrasonography and laboratory indices of NAFLD and some blood biochemical indicators in children. Methods: In this interventional study liver ultrasonography was performed in 200 children with overweight and obesity. A 108 had fatty liver among which 101 were randomly divided into two groups of study (n=51) and control (n=50). The study group was treated with Vit D, 50000 U once a week whereas the control group received placebo with the same dose and package, both for 12 weeks. At the end of the intervention lab tests and ultrasound study was performed once again to evaluate the response to treatment. Results: It was found out that Vit D supplementation improved the fatty liver grade in the study group. The mean changes in hemoglobin (Hb), uric acid, highdensity lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), insulin, albumin and alanine aminotransferase (ALT) was significantly higher in the study group compared to controls (p<0.05). After the intervention and means adjustment, a significant difference was obtained in HDL-C, insulin, LDL-C and homeostasis model assessment of insulin resistance (HOMA-IR) between the two groups. Conclusion: Vit D supplementation in addition to improving the fatty liver grade in ultrasonography and increasing the blood Vit D level, increases the HDL and Hb level besides decreasing uric acid, LDL, HOMA-IR, insulin and ALT levels.

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.