• Title/Summary/Keyword: interventional radiology

Search Result 229, Processing Time 0.024 seconds

Position Statements of the Emerging Trends Committee of the Asian Oceanian Society of Radiology on the Adoption and Implementation of Artificial Intelligence for Radiology

  • Nicole Kessa Wee;Kim-Ann Git;Wen-Jeng Lee;Gaurang Raval;Aziz Pattokhov;Evelyn Lai Ming Ho;Chamaree Chuapetcharasopon;Noriyuki Tomiyama;Kwan Hoong Ng;Cher Heng Tan
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.603-612
    • /
    • 2024
  • Artificial intelligence (AI) is rapidly gaining recognition in the radiology domain as a greater number of radiologists are becoming AI-literate. However, the adoption and implementation of AI solutions in clinical settings have been slow, with points of contention. A group of AI users comprising mainly clinical radiologists across various Asian countries, including India, Japan, Malaysia, Singapore, Taiwan, Thailand, and Uzbekistan, formed the working group. This study aimed to draft position statements regarding the application and clinical deployment of AI in radiology. The primary aim is to raise awareness among the general public, promote professional interest and discussion, clarify ethical considerations when implementing AI technology, and engage the radiology profession in the ever-changing clinical practice. These position statements highlight pertinent issues that need to be addressed between care providers and care recipients. More importantly, this will help legalize the use of non-human instruments in clinical deployment without compromising ethical considerations, decision-making precision, and clinical professional standards. We base our study on four main principles of medical care-respect for patient autonomy, beneficence, non-maleficence, and justice.

Ultrasound-Guided Intervention for Breast Lesions (유방 병변에 대한 초음파 유도하 중재 시술)

  • Eun Young Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.332-344
    • /
    • 2023
  • The role of ultrasound-guided interventions in the diagnosis and treatment of breast lesions is gaining importance and prevalence, particularly as the instances of non-palpable breast lesion detection, breast-conserving surgery, and neoadjuvant chemotherapy are increasing. This review attempts to summarize the types and techniques of breast ultrasound-guided interventional procedures, such as biopsy, tissue marker insertion, and preoperative localization, and their indications. Furthermore, we highlight the pro and cons of the most commonly used procedures with the intention of promoting their use in clinical practice.

Ginsenoside Rh2 inhibiting HCT116 colon cancer cell proliferation through blocking PDZ-binding kinase/T-LAK cell-originated protein kinase

  • Yang, Jianjun;Yuan, Donghong;Xing, Tongchao;Su, Hongli;Zhang, Shengjun;Wen, Jiansheng;Bai, Qiqiang;Dang, Dongmei
    • Journal of Ginseng Research
    • /
    • v.40 no.4
    • /
    • pp.400-408
    • /
    • 2016
  • Background: Ginsenoside Rh2 (GRh2) is the main bioactive component in American ginseng, a commonly used herb, and its antitumor activity had been studied in previous studies. PDZ-binding kinase/T-LAK cell-originated protein kinase (PBK/TOPK), a serine/threonine protein kinase, is highly expressed in HCT116 colorectal cancer cells. Methods: We examined the effect of GRh2 on HCT116 cells ex vivo. Next, we performed in vitro binding assay and in vitro kinase assay to search for the target of GRh2. Furthermore, we elucidated the underlying molecular mechanisms for the antitumor effect of GRh2 ex vivo and in vivo. Results: The results of our in vitro studies indicated that GRh2 can directly bind with PBK/TOPK and GRh2 also can directly inhibit PBK/TOPK activity. Ex vivo studies showed that GRh2 significantly induced cell death in HCT116 colorectal cancer cells. Further mechanistic study demonstrated that these compounds inhibited the phosphorylation levels of the extracellular regulated protein kinases 1/2 (ERK1/2) and (H3) in HCT116 colorectal cancer cells. In vivo studies showed GRh2 inhibited the growth of xenograft tumors of HCT116 cells and inhibited the phosphorylation levels of the extracellular regulated protein kinases 1/2 and histone H3. Conclusion: The results indicate that GRh2 exerts promising antitumor effect that is specific to human HCT116 colorectal cancer cells through inhibiting the activity of PBK/TOPK.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

Review of National Diagnostic Reference Levels for Interventional Procedures

  • Lee, Min Young;Kwon, Jae;Ryu, Gang Woo;Kim, Ki Hoon;Nam, Hyung Woo;Kim, Kwang Pyo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.75-88
    • /
    • 2019
  • Diagnostic reference level (DRL) is employed to optimize the radiation doses of patients. The objective of this study is to review the DRLs for interventional procedures in Korea and abroad. Literature review was performed to investigate radiation dose index and measurement methodology commonly used in DRL determination. Dose area product (DAP) and fluoroscopy time within each major procedure category were systematically abstracted and analyzed. A wide variation was found in the radiation dose. The DAP values and fluoroscopy times ranged 0.01-3,081 Gy·㎠ and 2-16,878 seconds for all the interventional procedures, 8.5-1,679 Gy·㎠ and 32-5,775 seconds for the transcatheter arterial chemoembolization (TACE), and 0.1-686 Gy·㎠ and 16-6,636 seconds for the transfemoral cerebral angiography (TFCA), respectively. The DRL values of the DAP and fluoroscopy time were 238 Gy·㎠ and 1,224 seconds for the TACE and 189 Gy·㎠ and 686 seconds for the TFCA, respectively. Generally, the DRLs of Korea were lower than those of other developed countries, except for the percutaneous transluminal angioplasty with stent in arteries of the lower extremity (LE PTA and stent), aneurysm coil embolization, and Hickman insertion procedures. The wide variation in the radiation doses of the different procedures suggests that more attention must be paid to reduce unnecessary radiation exposure from medical imaging. Furthermore, periodic nationwide survey of medical radiation exposures is necessary to optimize the patient dose for radiation protection, which will ultimately contribute to patient dose reduction and radiological safety.

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

Increased ERCP volume improves cholangiogram interpretation: a new performance measure for ERCP training?

  • Shyam Vedantam;Sunil Amin;Ben Maher;Saqib Ahmad;Shanil Kadir;Saad Khalid Niaz;Mark Wright;Nadeem Tehami
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.426-433
    • /
    • 2022
  • Background/Aims: Cholangiogram interpretation is not used as a key performance indicator (KPI) of endoscopic retrograde cholangiopancreatography (ERCP) training, and national societies recommend different minimum numbers per annum to maintain competence. This study aimed to determine the relationship between correct ERCP cholangiogram interpretation and experience. Methods: One hundred fifty ERCPists were surveyed to appropriately interpret ERCP cholangiographic findings. There were three groups of 50 participants each: "Trainees," "Consultants group 1" (performed >75 ERCPs per year), and "Consultants group 2" (performed >100 ERCPs per year). Results: Trainees was inferior to Consultants groups 1 and 2 in identifying all findings except choledocholithiasis outside the intrahepatic duct on the initial or completion/occlusion cholangiogram. Consultants group 1 was inferior to Consultants group 2 in identifying Strasberg type A bile leaks (odds ratio [OR], 0.86; 95% confidence interval [CI], 0.77-0.96), Strasberg type B (OR, 0.84; 95% CI, 0.74-0.95), and Bismuth type 2 hilar strictures (OR, 0.81; 95% CI, 0.69-0.95). Conclusions: This investigation supports the notion that cholangiogram interpretation improves with increased annual ERCP case volumes. Thus, a higher annual volume of procedures performed may improve the ability to correctly interpret particularly difficult findings. Cholangiogram interpretation, in addition to bile duct cannulation, could be considered as another KPI of ERCP training.

Comparison of conventional imaging techniques and CBCT for periodontal evaluation: A systematic review

  • Choi, Isabela Goulart Gil;Cortes, Arthur Rodriguez Gonzalez;Arita, Emiko Saito;Georgetti, Marco Antonio Pauperio
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.79-86
    • /
    • 2018
  • Purpose: This study aimed to carry out a systematic review of studies in the literature comparing conventional imaging techniques with cone-beam computed tomography in terms of the role of these techniques for assessing any of the following periodontal conditions and parameters: infrabony defects, furcation involvement, height of the alveolar bone crest, and the periodontal ligament space. Materials and Methods: Interventional and observational studies comparing conventional imaging techniques with cone-beam computed tomography were considered eligible for inclusion. The MEDLINE and Embase databases were searched for articles published through 2017. The PRISMA statement was followed during data assessment and extraction. Results: The search strategy yielded 351 publications. An initial screening of the publications was performed using abstracts and key words, and after the application of exclusion criteria, 13 studies were finally identified as eligible for review. Conclusion: These studies revealed cone-beam computed tomography to be the best imaging technique to assess infrabony defects, furcation lesions, the height of the alveolar bone crest, and the periodontal ligament space.

Endovascular Treatment for Head and Neck Trauma (두경부 외상의 인터벤션)

  • Jae Won Han;Jae Il Lee;Lee Hwangbo
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.792-808
    • /
    • 2023
  • Trauma to the head and neck region can have serious consequences for vital organs such as the brain, and injuries to blood vessels can cause permanent neurological damage or even death. Thus, prompt treatment of head and neck vessels is crucial. Although the level of evidence is moderate, an increasing amount of research indicates that endovascular treatments can be a viable alternative to traditional surgery or medical management. Embolization or reconstructive endovascular procedures can significantly improve patient outcomes. This article provides an overview of various endovascular options available for specific clinical scenarios, along with examples of cases in which they were employed.