• Title/Summary/Keyword: interventional

Search Result 587, Processing Time 0.028 seconds

Clinical Significance of Joint Detection of Serum VEGF, SIL-2R and HGF in Patients with Primary Hepatocellular Carcinoma before and after Percutaneous Microwave Coagulation Therapy

  • Chen, Ji-Dong;Xiong, Yan-Qun;Dong, Ke;Luo, Jun;Yue, Lin-Xian;Chen, Qin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4545-4548
    • /
    • 2014
  • Objective: To investigate the changes of serum vascular endothelial growth factor (VEGF), soluble interleukin-2 receptor (SIL-2R) and hepatocyte growth factor (HGF) contents in patients with primary hepatocellular carcinoma (HCC) before and after percutaneous microwave coagulation therapy (PMCT) and determine their clinical significance. Materials and Methods: Fasting venous blood (3 mL) from 81 patients with primary HCC diagnosed by pathology was collected in the mornings 1 day before PMCT, and 1 day, 7 days and 1 month after PMCT, and then the serum was separated and stored in $-70^{\circ}C$. The contents of VEGF, SIL-2R and HGF were detected by enzyme linked immunosorbent assay (ELISA). Results: The serum VEGF, SIL-2R and HGF contents in 81 patients with primary HCC had obviously dynamic changes before and after PMCT. By comparison to 1 day after PMCT with pre-operation, there was no statistical significance regarding VEGF and SIL-2R contents (P>0.05), but HGF content showed significant difference (P<0.01). Compared with pre-operation, VEGF, SIL-2R and HGF contents 7 days and 1 month after PMCT all manifested significant differences (P<0.01). By comparison to 7 days with 1 month after PMCT, there was no statistical significance regarding the VEGF content (P>0.05), whereas SIL-2R and HGF contents showed significant change (P<0.01). Conclusions: The contents of serum VEGF, SIL-2R and HGF have obviously dynamic changes in primary HCC before and after PMCT, and their joint detection is expected to be an effective hematologic evaluation index of PMCT for primary HCC.

Interventional Approaches for Treatment of Saddle Embolus in Two Cats with Hypertrophic Cardiomyopathy (고양이 심근비대증에 병발한 안장색전증의 중재치료 증례)

  • Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.298-302
    • /
    • 2014
  • An 8-year-old castrated male domestic shorthair cat (Case 1) and 3-year-old castrated male Siamese cat (Case 2) was presented with acute paresis of the hindlimbs, constant open-mouth breathing, and hemoptysis. Heart murmur (Case 1) and gallop sound (Case 2) was ausculated on the left heart base. Radiographs revealed alveolar infiltration of the caudodorsal lung lobes with aerophagea in Case 1 and prominent cardiomegaly in Case 2. Marked concentric hypertrophy of the ventricular septum and free wall, and left atrial enlargement was detected through echocardiography in both cats. Based on the examinations including echocardiography, those cats were diagnosed as hypertropic cardiomyopathy. Abdominal ultrasound revealed echogenic material in the aortic trifurcation region, aortic thromboembolism (ATE). Although prognosis of those animals was guarded, interventional therapeutic approach through direct endovascular thrombolytic therapy was attempted. ATE was visualized through angiography; however dissolving the embolus using interventional thrombolytic approach was not successful due to the extensive thrombus.

Review of National Diagnostic Reference Levels for Interventional Procedures

  • Lee, Min Young;Kwon, Jae;Ryu, Gang Woo;Kim, Ki Hoon;Nam, Hyung Woo;Kim, Kwang Pyo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.75-88
    • /
    • 2019
  • Diagnostic reference level (DRL) is employed to optimize the radiation doses of patients. The objective of this study is to review the DRLs for interventional procedures in Korea and abroad. Literature review was performed to investigate radiation dose index and measurement methodology commonly used in DRL determination. Dose area product (DAP) and fluoroscopy time within each major procedure category were systematically abstracted and analyzed. A wide variation was found in the radiation dose. The DAP values and fluoroscopy times ranged 0.01-3,081 Gy·㎠ and 2-16,878 seconds for all the interventional procedures, 8.5-1,679 Gy·㎠ and 32-5,775 seconds for the transcatheter arterial chemoembolization (TACE), and 0.1-686 Gy·㎠ and 16-6,636 seconds for the transfemoral cerebral angiography (TFCA), respectively. The DRL values of the DAP and fluoroscopy time were 238 Gy·㎠ and 1,224 seconds for the TACE and 189 Gy·㎠ and 686 seconds for the TFCA, respectively. Generally, the DRLs of Korea were lower than those of other developed countries, except for the percutaneous transluminal angioplasty with stent in arteries of the lower extremity (LE PTA and stent), aneurysm coil embolization, and Hickman insertion procedures. The wide variation in the radiation doses of the different procedures suggests that more attention must be paid to reduce unnecessary radiation exposure from medical imaging. Furthermore, periodic nationwide survey of medical radiation exposures is necessary to optimize the patient dose for radiation protection, which will ultimately contribute to patient dose reduction and radiological safety.

Analysis on Content and Trend of Nursing Intervention Studies Published in Adult Nursing Area (성인간호학 영역에서의 간호중재논문 내용 분석)

  • Suh, Moon-Ja;Jeong, Jae-Sim;Oh, Hyo-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.5 no.2
    • /
    • pp.41-51
    • /
    • 2003
  • Purpose : This descriptive study was performed to analyze the trends of nursing interventional studies in adult nursing area. Method : All interventional studies of 'Journal of Korean Academy of Adult Nursing Society', fifty three articles, from 1989 to 2000 were collected and reviewed Result : The research subject were patients in 38(66.7%) and 81.8% of researches was performed in hospital environment. There was only one true experimental design and most of articles(79.2%) were designed by quasi-experimental method Only 17% of articles have theoretical framework and 73.6% of articles described research hypotheses. The data collection methods for variables were as follows: Psychosocial measurement 60.8%, physiological measurement 25.7%, and observation 13.5%, respectively. Lecture(16.7%), audio-visual(16.7%), and book, pamphlet, or leaflets(13.6%) were the most frequently used instruments of the interventions. Behavioral domain(60.3%) and Physiological: Basic domain(29.3%) was the most common, when the interventions were classified by Nursing Intervention Classification. Physiological(50.8%) and psychosocial variables(49.2%) were the two major dependent variables. Conclusion : Considering the above results obtained, the nursing intervention studies in adult nursing area have been tested with quasi-experimental studies through clinical trials. For the development of clinical nursing practice and advancement of nursing theories, the amount of interventional studies should be increased and the quality of research methods refined more to develop nursing science and practice in adult nursing area.

  • PDF

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

Development of Drug Eluting Stent for the Treatment of Benign Biliary Stricture by Electro-spray Method (전기분사를 이용한 양성담관 협착 치료용 약물방출 스텐트 개발)

  • Shin, Il-Gyun;Kim, Dong-Gon;Kim, Han-Ki;Kim, Sang-Ho;Jeon, Dong-Min;Suh, Tae-Seok;Jang, Hong-Seok
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.163-168
    • /
    • 2012
  • Recently, along with technology development of endoscopic equipment, the stent technology has been developed for the convenience of operation, shortening of recovery times, and reduction of patient's pain. In this study, paclitaxel-eluting metal stents for treatment of biliary benign stenosis were developed through an electrospray-coating method. Polyether-based polyurethane (PELLETHANE 2363-80AE$^{(R)}$)) and paclitaxel were coated onto the surface of a metallic stent and Pluronic F127 was used as an additive. As a result, physicochemical characterization of paclitaxel via SEM, FTIR, contact angle and XRD techniques revealed the information of solid state of paclitaxel-loaded PU film. The in vitro release profile showed a slower release rate with a higher content of paclitaxel.

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

A Study of Diagnostic Reference Levels for Coronary Angiography and Percutaneous Coronary Intervention in Gyeongsang Area (관상동맥 조영술 및 경피적 관상동맥 중재술에 대한 진단참고준위에 관한 연구; 경상도지역중심)

  • Si-Wang Lim;Jung-Su Kim;Pyong-Kon Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.123-129
    • /
    • 2023
  • Interventional cardiology procedures can involve relatively high radiation doses compared to conventional radiography. During CAG, CAG + PCI and PCI the same area is exposed to radiation for a long period. In this study, radiation exposure data of 421 examinations in Gyeongsang area were collected, and the DRLs and ADs in actual medical practice for three types of interventional cardiology procedures in Korea were established. In CAG 286 case, 75th percentile DRLs and ADs of the total DAP were 55.89 Gy·cm2 and 37.47 Gy·cm2 , respectively. In CAG + PCI 92 case, those values were 222.84 Gy·cm2 and 117.51 Gy·cm2 respectively. In PCI 43 case, those values were 198.73 Gy·cm2 and 120.13 Gy·cm2 respectively. In this study, for the first time, the diagnostic reference level of interventional cardiology procedures in Gyeongsang area were established. Using the diagnostic reference level of interventional cardiology procedures derived from this study, it will help to identify and improve the level of exposure dose in the region and country.

The Role of Interventional Radiology in Treatment of Patients with Acute Trauma: A Pictorial Essay (급성 외상 환자 치료에서 인터벤션 영상의 역할: 임상화보)

  • Kyung Sik Kang;Mu Sook Lee;Doo Ri Kim;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.347-358
    • /
    • 2021
  • Acute trauma is a common cause of mortality in individuals aged < 40 years. As organ preservation has become important in treating trauma patients, the treatment is shifting from surgical management to non-operative management. A multidisciplinary team approach, including interventional radiology (IR), is essential for the optimal management of trauma patients, as IR plays an important role in injury evaluation and management. IR also contributes significantly to achieving the best clinical outcomes in critically ill trauma patients. This pictorial essay aims to present and summarize various interventional treatments in trauma patients requiring critical care.