• Title/Summary/Keyword: interval scanning

Search Result 103, Processing Time 0.029 seconds

Use of OSMI(Ocean Scanning Multi-spectral Imager) Wave Bands for Agricultural Applications

  • Hong, Suk-Young;Rim, Sang-Kyu;Jung, Won-Kyo
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.396-402
    • /
    • 1999
  • The aim of this study is to assess the OSMI (Ocean Scanning Multi-spectral Imager), whose central bands are 443nm, 490nm, 510nm, 555nm, 670nm, and 865nm, for agricultural applications. Radiance measurements, used to determine per cent reflectance of canopies and soils, were acquired with spectro-radiometers (Li-1800;330~1,100nm, GER-SFOV;350 ~2,500nm, and MSR-7000; 300~2,500nm) in situ for crops and indoors for soils. OSMI equivalent bands and their ratio values were prepared(20nm interval for bands 1~5; 4nm interval for band 6) by averaging spectral reflectance values to the real OSMI bands and analyzed as to crop growth parameters, leaf area index (LAI), total dry matter, and growth index in crops and physiochemical properties in soils. Spectral variations for each growth stage in rice and for crop discrimination in upland crops were significant statistically. In soils, clay and water content, CEC (Cation Exchange Capacity), free iron oxide, and some cation content were correlated with the OSMI equivalent bands. The result of this study shows OSMI wave bands would be promising for agricultural application in terms of spectral information and resolution.

  • PDF

Diagnosis and Treatment of the Recurrent Thyroid Cancer (갑상선 재발암의 진단과 치료에 대한 고찰)

  • Kwon O-Gyoung;Park Sung-Gil;Oh Sung-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2000
  • Objectives: To demonstrate effective diagnostic method and proper management of recurrent thyroid cancer through to compare treatment and surveillance of $I^{131}$ scanning detected recurrence and clinically detected recurrence. Material and Methods: We retrospectively analyzed clinical information about 46 patients who has recurrent thyroid cancer of 298 patients who have been primarily operated due to thyroid cancer in PMC at the over 10 years between 1986 and 1995. We examine incidence of recurrence due to pathologic types, site of recurrence, disease free interval, detection method of recurrence, and also treatment and progression of recurrence. A patients in which the clinical examination was entirely negative and the $I^{131}$ scan demonstrated either a new area of $I^{131}$ uptake or an increased area of concentration, compared to the previous scan, was designated as a recurrence detected by $I^{131}$ scan only. Recurrences that were obviously by physical examination or chest x-ray, etc were considered clinically detected recurrence, regardless of the the results of the thyroid scan. Results: Mean of disease tree interval(DFI) is 36months. When mean DFI of $I^{131}$ scan detected recurrence is 28months, whereas mean DFI of clinically detected recurrence is 47months. In statiscal analysis, p-value is 0.043 as significantly. In progression of recurrent patient, NED is 28case, AWD is Sease, DOD is 13case. Among the 13case, scan detected recurrence is lease of 20 patients(5%), whereas clinically detected recurrence is l2case of 26 patient(46%). In statiscal analysis, p-value is 0.003 as significantly. Conclusion: Early detection of the recurrent thyroid cancer by $I^{131}$ scanning leads to good progress compare with detection by clinical examination. NED: No Evidence of Disease AWD : Alive With Disease DOD : Dead Of Disease DOC: Dead of Other Cause

  • PDF

Dynamic Characteristic Improvement of Laser Scanning Unit for Laser Beam Printer (레이저 프린터용 광스캔유닛(LSU) 의 동특성 개선)

  • 조문선;차덕순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.189-193
    • /
    • 2001
  • The performance of printer can be determined by the printing speed, noise level, printing quality which includes the resolution, regularity of printed matter and etc. Among them, printing quality mostly depends on the irregularity of the line spacing and dot size. The irregular line spacing and dot size in laser beam printer are mainly from the jitter which comes from the vibration of Organic Photo Conductive(OPC) drum and the Laser Scanning Unit(LSU). Jitter due to the vibration of LSU appears as high-frequency component which occurs 100-300$\mu\textrm{m}$ interval in printed matter and the causes of it can be estimated as the vibration of polygon motor, case, reflecting mirror and etc. In this paper, vibration characteristics of the LSU under development are investigated and the strategy for improvement of the dynamic characteristics is established and its validity is demonstrated.

  • PDF

Transition State Characterization of the Low- to Physiological-Temperature Nondenaturational Conformational Change in Bovine Adenosine Deaminase by Slow Scan Rate Differential Scanning Calorimetry

  • Bodnar, Melissa A.;Britt, B. Mark
    • BMB Reports
    • /
    • v.39 no.2
    • /
    • pp.167-170
    • /
    • 2006
  • Bovine adenosine deaminase undergoes a nondenaturational conformational change at $29^{\circ}C$ upon heating which is characterized by a large increase in heat capacity. We have determined the transition state thermodynamics of the conformational change using a novel application of differential scanning calorimetry (DSC) which employs very slow scan rates. DSC scans at the conventional, and arbitrary, scan rate of $1^{\circ}C/min$ show no evidence of the transition. Scan rates from 0.030 to $0.20^{\circ}C/min$ reveal the transition indicating it is under kinetic control. The transition temperature $T_t$ and the transition temperature interval ${\Delta}T$ increase with scan rate. A first order rate constant $k_1$ is calculated at each $T_t$ from $k_1\;=\;r_{scan}/{\Delta}T$, where $r_{scan}$ is the scan rate, and an Arrhenius plot is constructed. Standard transition state analysis reveals an activation free energy ${\Delta}G^{\neq}$ of 88.1 kJ/mole and suggests that the conformational change has an unfolding quality that appears to be on the direct path to the physiological-temperature conformer.

An Efficient Algorithm for Mining Ranged Association Rules (영역 연관규칙 탐사를 위한 효율적 알고리즘)

  • 조일래
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.2
    • /
    • pp.169-181
    • /
    • 1997
  • Some association rules can have very high confidence in a sub-interval or a subrange of the domain, though not quite high confidence in the whole domain. In this paper, we define a ranged association rule, an association with high confidence worthy of special attention in a sub-domain, and further propose an efficient algorithm which finds out ranged association rules. The proposed algorithm is data-driven method in a sense that hypothetical subranges are built based on data distribution itself. In addition, to avoid redundant database scanning, we devise an effective in-memory data structure, that is collected through single database scanning. The simulation shows that the suggested algorithm has reliable performance at the acceptable time cost in actual application areas.

  • PDF

The Associations of Online Health Information Search and eHealth Literacy with Perceived Information Usefulness: Analysis in the Context of Diet and Weight Control (인터넷 건강정보이해능력과 정보탐색 유형별 인지된 정보유용성 분석: 다이어트 및 체중조절 관련 정보탐색을 중심으로)

  • Shim, Minsun;Jo, Heui Sug;Jung, Su Mi
    • Health Policy and Management
    • /
    • v.28 no.2
    • /
    • pp.119-127
    • /
    • 2018
  • Background: This study aimed to examine (1) the patterns of online health information search with respect to seeking and scanning, and (2) how online search, along with eHealth literacy, predicts perceived information usefulness in the context of diet and weight control. Methods: Online survey was conducted with 299 adults from the consumer panel recruited for the purpose of quality assessment of the Korean National Health Information Portal in 2016. We conducted paired sample t-test and multiple logistic regression to address the research questions. Data analysis was performed using IBM SPSS Statistics ver. 24.0 (IBM Corp., Armonk, NY, USA) and SAS ver. 9.3 (SAS Institute Inc., Cary, NC, USA). Results: Of the respondents, 38.8% were 'high seek-high scanners,' 35.8% were 'low seek-low scanners,' 13.0% were 'high seek-low scanners,' and 12.4% were 'low seek-high scanners.' eHealth literacy was a significant, positive predictor of online information scanning (odds ratio [OR], 2.46; 95% confidence interval [CI], 1.41-4.29), but not for online information seeking (OR, 1.75; 95% CI, 1.00-3.05). With respect to perceived usefulness of online information seeking, online seeking (OR, 4.90; 95% CI, 2.19-11.00) and eHealth literacy (OR, 2.30; 95% CI, 1.11-4.75) were significant predictors. Perceived usefulness of online scanning had a significant association with online scanning (OR, 2.38; 95% CI, 1.08-5.22), but not with eHealth literacy. Conclusion: To increase the effectiveness of the health policy for online information search and related outcomes in the context of diet and weight control, it is important to develop education programs promoting eHealth literacy.

A Study on the Eye-Hand Coordination for Korean Text Entry Interface Development (한글 문자 입력 인터페이스 개발을 위한 눈-손 Coordination에 대한 연구)

  • Kim, Jung-Hwan;Hong, Seung-Kweon;Myung, Ro-Hae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.149-155
    • /
    • 2007
  • Recently, various devices requiring text input such as mobile phone IPTV, PDA and UMPC are emerging. The frequency of text entry for them is also increasing. This study was focused on the evaluation of Korean text entry interface. Various models to evaluate text entry interfaces have been proposed. Most of models were based on human cognitive process for text input. The cognitive process was divided into two components; visual scanning process and finger movement process. The time spent for visual scanning process was modeled as Hick-Hyman law, while the time for finger movement was determined as Fitts' law. There are three questions on the model-based evaluation of text entry interface. Firstly, are human cognitive processes (visual scanning and finger movement) during the entry of text sequentially occurring as the models. Secondly, is it possible to predict real text input time by previous models. Thirdly, does the human cognitive process for text input vary according to users' text entry speed. There was time gap between the real measured text input time and predicted time. The time gap was larger in the case of participants with high speed to enter text. The reason was found out investigating Eye-Hand Coordination during text input process. Differently from an assumption that visual scan on the keyboard is followed by a finger movement, the experienced group performed both visual scanning and finger movement simultaneously. Arrival Lead Time was investigated to measure the extent of time overlapping between two processes. 'Arrival Lead Time' is the interval between the eye fixation on the target button and the button click. In addition to the arrival lead time, it was revealed that the experienced group uses the less number of fixations during text entry than the novice group. This result will contribute to the improvement of evaluation model for text entry interface.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

A Study on the Morphological Changes of Actual Hair Cuticles by Different Types of Conditioner after Coloring Treatment (염색시술 후 사용한 컨디셔너의 종류에 따른 모표피층의 형태 변화 연구)

  • Choi, Jung-Myung;Na, Hyun-Joon;Park, Shin-Jung;Chang, Jee-Hye
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.3 no.1 s.4
    • /
    • pp.72-77
    • /
    • 2005
  • The present study was to investigate the effects of different types of conditioner on the morphological changes of hair cuticles after coloring treatment. The virgin hair, aged 22 years served as a subject. Coloring treatment was done with a commercial hair dye agent for 35 minutes as routine procedures at $25^{\circ}C$, 50% R.H. environmental condition. The two different types of conditioner, Essence and LPP were applied to the colored hair 10 times with 2 days interval for 20 days. The hair cuticles were observed by a scanning electron micro scopy before and after coloring and conditioner treatment. The main results were as follows. Coloring treatment damaged the hair cuticles, and both of Essence and LPP had a direct conditioning effect. Also, the damaged hair cuticles were recovered by the repeated application of hair conditioner. Moreover, LPP was more effective in hair curing compared to Essence. These results show that a hair conditioner can be helpful to keep healthy hair and to shorten an interval of coloring.

  • PDF

A Field Experiment Study on the Use of OSMI Wave Bands for Agricultural Applications

  • Hong, Suk-Young;Rim, Sang-Kyu;Jung, Won-Kyo
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.4
    • /
    • pp.307-319
    • /
    • 1999
  • The aim of this study is to assess the OSMI (Ocean Scanning Multi-spectral Imager), whose central bands are 443nm, 490nm, 510nm, 555nm, 670nm, and 865nm, for agricultural applications. Radiance measurements, used to determine per cent reflectance of canopies and soils, were acquired with spectro-radiometers (Li-1800;330∼1,100nm, GER-SFOV;350∼2,500nm, and MSR-7000; 300∼2,500nm) in situ for crops and indoors for soils. OSMI equivalent bands and their ratio values were prepared(20nm interval for bands 1∼5; 40nm interval for band 6) by averaging spectral reflectance values to the real OSMI bands and analyzed as to crop growth parameters, leaf area index (LAI), total dry matter, and growth index in crops and physiochemical properties in soils. Spectral variations for each growth stage in rice and for crop discrimination in upland crops were significant statistically. In soils, clay and water content, CEC (Cation Exchange Capacity), free iron oxide, and some cation content were correlated with the OSMI equivalent bands. The result of this study shows OSMI wave bands would be promising for agricultural application in terms of spectral information and resolution.