• Title/Summary/Keyword: international key comparison

검색결과 115건 처리시간 0.027초

국가표준향상과 핵심국제비교를 위한 물의 삼중점 온도 측정 (Measurement of triple point of water temperature for improvement of the national standards and key comparison)

  • 양인석;이영희
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.349-356
    • /
    • 2021
  • The Korea Research Institute of Standards and Science (KRISS), a National Metrology Institute of Korea, participated in the second-round of the international key comparison CCT-K7.2021 of triple point of water (TPW) cells. For the key comparison, three TPW cells, one of which had been used in the old CCT-K7 comparison, were assigned as the national standard of the TPW. The temperature difference (ΔT) between the average of the new and old national standards and ΔT between the new national standard and the transfer standard were measured. The comparison between the new and old national standards indicated a temperature increase of 69.5 µK after both the standards were corrected for the isotopic composition. The uncertainty of the national standard of the TPW temperature was 28 µK, and the uncertainty of ΔT was 14 µK. Three aspects of improvements in the new comparison compared to the old one were noted: (1) inclusion of two quartz cells in the national standard strengthens its long-term stability; (2) the standard deviation associated with the measurement of ΔT was reduced from 21 µK to 9.6 µK; (3) and the measured immersion profile of the TPW cells was much closer to the theoretically predicted dependence.

전기저항의 국제비교 및 계측기술에 관한 국제적 상호인정 추세 (International Comparison of high resistance and Mutual Recognition between National Metrology Institutes)

  • 유광민;류제천;강전홍;김한준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.606-608
    • /
    • 1999
  • Mutual Recognition Agreement(MRA) between national metrology institutes is started on October 1999 and International Key Comparison is essentially to be used as technical basis for the agreement. High resistance is one of the Key Comparison and high resistance measurement system is established in KRISS for the purpose of the Key Comparison. Total combined uncertainty of the system is about 4ppm in $10M{\Omega}$ and 8ppm in $1G{\Omega}$. With the system, the difference of comparison results for $10M{\Omega}$ and $1G{\Omega}$ among KRISS, VNIIM in Russia and NIM in China is agreed about 6ppm within total combined uncertainty of three institutes.

  • PDF

직류-교류 자기장 표준 시스템 제작 및 국제비교 결과 (Construction of AC-DC Magnetic Field Standard Systems and Results of International Key Comparison)

  • 박포규;김영균
    • 한국자기학회지
    • /
    • 제14권6호
    • /
    • pp.201-206
    • /
    • 2004
  • 자기장 측정기 교정 및 자기관련 시험 등에 사용되는 직류 및 교류 자기장 표준시스템을 제작하였다. 자기장 1 mT범위에서, 직류의 경우 확장불확도(expanded uncertainty, 2$\sigma$)는 8${\times}$$10^{-6}$, 교류의 경우, 주파수에 따른 확장불확도는 0.1~1 kHz 범위에서 0.16%, 1~5kHz에서 0.26%, 5~20kHz에서 0.44%이었다. 또한 국가측정표준에 대한 동등성과 수행한 교정 및 측정에 대한 국가간 상호인정을 받기 위하여 이 분야의 핵심측정표준 국제비교(international key comparison)에 참여하였다. 선진국과 대등한 결과를 얻었으며, 자기장 분야의 측정능력이 세계적 수준임을 확인하는 계기가 되었다.

핵심국제비교용 물의 삼중점 셀 제작과 비교 실험 및 불확도 평가 (Construction and Comparison Measurement of Triple Point Water Cells for using Key Comparison and Evaluation of Uncertainty)

  • 강기훈;김용규;감기술
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.114-120
    • /
    • 2004
  • The $Comet{\acute{e}}$ Consultatif de $Thermom{\acute{e}}trie$ (CCT) under the Comete International des Poids et Measures (CIPM) has decided to perform the Key Comparison (KC) for triple point of water cells used as a reference fixed point of thermometry at the 21st meeting held at November 2001, and the Bureau International des Poids et Measures (BIPM) has been nominated as a KC coordinator. According to the KC protocol prepared by BIPM, KRISS performed the KC experiments and evaluate a uncertainty. The temperature difference between two reference cells for the Korea Research Institute of Standards and Science (KRISS) and a test cell for the transfer standard, which is moved to BIPM was 0.024 mK and the combined standard uncertainty evaluated 0.055 mK.

LS1P 마이크로폰 핵심측정표준 국제비교 결과 (Results of Key Comparison on LS1P Microphones)

  • 서재갑;조문재;권휴상;서상준
    • 한국음향학회지
    • /
    • 제24권4호
    • /
    • pp.194-201
    • /
    • 2005
  • 국제적으로 음향$\cdot$초음파$\cdot$진동분야의 정밀계측 필요성이 점차 강조되고 있기 때문에 1998년도에 국제도량형위원회(CIPM; International Committee for Weights and Measures) 산하에 음향$\cdot$초음파$\cdot$진동 자문위원회 (CCAUV; Consultative Committee for Acoustics, Ultrasound and Vibration)가 신설되어 활동을 시작하였다. 그 첫 번째 사업의 하나가 1999년부터 시작된 음향분야의 1" 표준 마이크로폰에 대한 핵심측정표준 국제비교 (Key Comparison)이다. 1" 표준 마이크로폰 핵심측정표준 국제비교는 1999년 4월부터 2001년 4월까지 진행되었으며 한국표준과학연구원을 포함한 12개 국가표준기관이 참여하였다. 주관기관 (pilot lab.)은 영국의 National Physical Laboratory (NPL)이 맡았다. 이동용 표준기는 IEC 61094-1에 명시된 1" 표준 음압형 마이크로폰 (LS1P Microphone; Laboratory Standard 1" Pressure Type Microphone) 두 개이며 교정 주파수 범위는 63 Hz부터 8 kHz까지이다. 본 논문에서는 최종 보고서에 수록된 분석 결과를 요약하여 정리하였다.

Comparison of NAEP, PISA, and TIMSS-R

  • Kim, Young-Ok;Wakhungu, Henry Kerre;Ku, In-Suk
    • East Asian mathematical journal
    • /
    • 제25권3호
    • /
    • pp.279-297
    • /
    • 2009
  • This paper discusses the key differences and common themes among three major assessments of pre-college mathematics learning: Program for International Student Assessment (PISA), Third International Mathematics and Science Study Repeat (TIMSS-R), and National Assessment of Educational Progress (NAEP).

Comparison of the standards for absorbed dose to water of the IAEA and the KRISS, Korea in accelerator photon beams

  • L. Czap;I.J. Kim;J.I. Park;C.-Y. Yi;Y. Kim;Z. Msimang
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2698-2703
    • /
    • 2024
  • A bilateral comparison was conducted between the International Atomic Energy Agency (IAEA) and the Korea Research Institute of Standards and Science (KRISS) to measure the absorbed dose to water in accelerator photon beams. KRISS served as a linking laboratory to compare the IAEA standard with the key comparison reference value (KCRV) of the BIPM.RI(I)-K6 program, in which KRISS participated in 2017. Two ionization chambers from the IAEA were used as transfer instruments for the comparison. Both laboratories measured the calibration coefficients of these instruments and calculated the ratios. The ratio of the KRISS standard to the KCRV was applied to obtain the degree of equivalence of the IAEA, along with its uncertainty. The largest deviation of the IAEA measurement from the KCRV was 3.4 mGy/Gy, significantly smaller than the expanded uncertainty of 10.7 mGy/Gy (k = 2, 95% level of confidence). This study demonstrates the equivalence of IAEA's measurement standard for accelerator photon beams to other primary standard dosimetry laboratories. It provides evidence for the satisfactory operation of IAEA's quality management system and enhances the international credibility of the IAEA SSDL network, particularly in high-energy accelerator photon beams from linear accelerators.

An International Comparison of Technological Systems : The Case of CNC Machine Tools in Korea, Sweden, and U.S.A.

  • Sung, Tae-Kyung;Carlsson, Bo
    • 기술혁신연구
    • /
    • 제12권2호
    • /
    • pp.21-46
    • /
    • 2004
  • Focusing on a product, this paper reconstructs the concept of technological systems first introduced by Carlsson and Stankiewicz (1991). Based on the model and our earlier works, we compare the salient features of technological systems for computer numerically controlled (CNC) machine tools in Korea, Sweden, and the United States.. We also try to measure the performance of the systems in an international comparison. Major findings are as follows: (1) The length of 'learning period' for local (national) technological system is substantial, even though it is a catching-up case. (2) The key success factor of the technological system appears to be the connectivity among various actors or infrastructures, rather than just the existence or formation of those. (3) In three countries' experience, the government played an important role in the formation of each own technological system. (4) The performance of Korea's technological system for CNC machine tools during the past two decades(1981-97) seems to be better than that of Sweden and the U.S. Lastly, many policy implication are presented.

  • PDF

학위논문 주제어 중심 연구동향 분석 -국어국문학, 국어교육학, 한국어교육학 분야를 중심으로- (esearch Trend Analysis Focused on Thesis Key Words: in the Fields of Korean Language and Literature, Korean Language Education, and Korean Language Education as a Foreign Language)

  • 김은실;강승혜
    • 한국어교육
    • /
    • 제29권2호
    • /
    • pp.25-48
    • /
    • 2018
  • The aim of this study was to analyze research trends in the fields of Korean Language and Literature, Korean Language Education, and Korean Language Education as a Foreign Language. To this end, key words were extracted from 29,470 academic theses published between 2000 and 2017. The results of the analysis are as follows. First, in the field of Korean Language and Literature, there is greater quantity in studies about Korean language than about literature, and starting from 2010, there was an increase in studies similar to those from the field of Korean Language Education as a Foreign Language. Next, in comparison to the other fields, the field of Korean Language Education has greater variance in its research theme-in particular, numerous studies related to the site of education. Finally, the field of Korean Language Education has the following trends: a) there are copious studies focused on Korean language learners in comparison to other fields, b) there are a greater number of studies focused on culture, and c) the key words change by time period which suggest that research demands transformed over time. Overall, a total of 64 highest frequency key words from the three academic fields were investigated. Of these, 22 were common key words and 42 were differential key words. In this way, it was possible to illuminate the identity of each field.