• 제목/요약/키워드: internal pressures

검색결과 230건 처리시간 0.026초

자긴가공된 이중실린더의 기계가공효과 (Machining effect of the Autofrettaged Compound Cylinder)

  • 박재현;이영신;김재훈;공정표;차기업
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.620-625
    • /
    • 2007
  • Autofrettage process is used for internal forming and sizing of cylinder designed to withstand high internal pressures. Once the tube is autofrettaged, it needs to be machined to its final dimensions both at the bore and its outer surface. This paper presents an analytical analysis and numerical analysis of machined compound cylinder using finite element code, ANSYS10.0. An analytical model for predicting the level of autofrettage following either inner, outer, or combined machining of the compound cylinder is developed for the autofrettage residual stress field is simulated by an autofrettaged pressure. The autofrettaged pressures are obtained by using trying-error method. As autofrettage percentage is 20 %, the numerical results are found to be in almost agreement with the analytical ones. However, as autofrettage percentage is 60 %, the numerical results have a little difference with the analytical ones.

  • PDF

Design and Experiment of a Micro Electronic System for Prediction of Alveolar-Gas Partial Pressures

  • Kim, Da-Jung;Chang, Keun-Shik;Kim, Sa-Ji;Park, Hye-Yun;Suh, Gee-Young
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.187-193
    • /
    • 2010
  • In this study we have designed and fabricated an inexpensive micro electronic system that we call Alvitek. It can indirectly but accurately predict and display the partial pressures of alveolar oxygen and carbon dioxide for the patients in the ICU of a hospital. Alvitek consists of both hardware part and software part. Performance of the system is tested by animal experiment with pigs for various $F_{t}e_{2}$ and RR(Respiratory Rate) values under the mechanical ventilation. The predicted alveolar gas partial pressures are cprpared with the approximate alveolar oxygen partial pressures easily calculated by the physician’s bedside formula. As a result, we have concluded that the relative error of A-$aDe_2$ calculated by the bedside formula grows seriously for lower $F_{t}e_{2}$ values. The present prediction method of Alvitek is henceforth believed very meaningful to the physicians. The system hardware and software are described in the text.

A study on the performance and internal flow of inline Francis turbine

  • Chen, Chengcheng;Inagaki, Morihito;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1225-1231
    • /
    • 2014
  • This paper presents the performance characteristic of a Francis hydro turbine with an inline casing. This turbine is designed for city water supply system. Due to large changes in ground elevation with high points and low points, some systems may experience larger-than-normal required pressures in areas with low ground elevations. One way to dissipate these excess pressures is by the use of an inline-turbine instead of an inline-pressure reducing valve. For best applicability and minimal space consumption, the turbine is designed with an inline casing instead of the common spiral casing. As a characteristic of inline casing, the flow accesses to the runner in the radial direction, showing a low efficiency. The installation of vanes improves the internal flow and gives the positive encouragement to the output power. For the power transmission to the outside of the turbine casing from the runner axis, a belt passage is designed in the inline casing, as its influence, the region after the belt passage shows a relatively low output power. The clearance gap in the runner side space is considered, in which a small volume of flow is contracted into the clearance gap, forming the leakage flow. The leakage flow leads to a decrease in the efficiency.

음향섭동에 의한 후류유동의 제어 (Wake Flow Control by Acoustic Perturbation)

  • 이종춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.451-459
    • /
    • 1998
  • THe influence of internal acoustic exitation through a square prism on the turbulent wake flow characteristics was investigated. The intermediate wake region where is about ten times the respective length of the body was experimentally investigated using a conditional phase average technique. At first the static base pressures of square prism and the shedding frequencies have been measured at various internal acoustic exciation frequencies. The experiment were performed under the four cases of internal acoustic excitation frequencies 0Hz 30Hz($St_e$=0.09) 65Hz($St_e$=0.20) 120Hz($St_e$=0.38) And velocity vector fields were presented and discussed. The influence of acoustic exvitation frequencies on the structure of intermediate turbulent wake region is evident. As the internal acoustic frequency increased shedding frequency gradually increased and aerodynamic force decreased. Also it was found that the vortex shedding occurs dratically well and shedding frequency reached nearly the same value as the internal acoustic frequency. but above Strouhal number 0.3 the influence disappeared.

  • PDF

가스발생기용 스월 동축형 인젝터에서 내부 유동의 특성에 대한 실험적 연구 (Experimental Study on the Internal Flow Characteristics in a Swirl Coaxial Injector for Gas Generator)

  • 김성혁;윤정수;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.29-33
    • /
    • 2010
  • 본 연구는 Kerosene-LOx를 추진제로 하는 가스발생기용 스월 동축형 인젝터의 리세스 길이에 따른 내부 유동의 특성 파악을 목표로 하였다. 리세스 길이는 분무 안정성, 내부 LOx post 손상 등에 영향을 미치는 중요한 요소로 액막두께, 매니폴드 압력 측정 및 내부 유동 가시화를 통해 리세스의 영향을 분석하였다. 또한, 리세스 길이에 따른 내부 또는 외부 인젝터 각각의 분무특성도 살펴보았다.

  • PDF

사출성형 공정에서 고화층이 캐비티 압력에 미치는 영향 (Frozen Layer Effect on Internal Cavity Pressure during Injection Molding)

  • 이호상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.474-479
    • /
    • 2005
  • Experimental and theoretical studies of internal cavity pressure during injection molding of a spiral tube cavity were carried out. The frozen layer thickness and the evolution of internal cavity pressure were calculated using a commercial software (C-MOLD). The evolution of the internal cavity pressure was recorded during injection molding of polystyrene into a spiral tube mold. To explain the differences observed between the calculated and measured internal cavity pressure, a pressure correction factor (PCF) was introduced based on the plane stress theory. This factor was determined by analyzing the stress state in the melt and calculating the frozen layer thickness near the mold wall. The corrected and experimental pressures have been compared to validate the applicability of the pressure correction factor.

  • PDF

정량적인 핵연료봉 내압 설계기준에 관한 연구 (Study on the Quantitative Rod Internal Pressure Design Criterion)

  • Kim, Kyu-Tae;Kim, Oh-Hwan;Han, Hee-Tak
    • Nuclear Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.363-373
    • /
    • 1991
  • 핵연료봉 내압 설계기준에 의하면 핵연료봉 갭의 증가만 발생하지 않는다면 봉내압이 계통압력을 초과할 수 있다. 본 연구에서는 이러한 봉내압 설계기준에 따른 정량적이고 보수적인 허용 봉내압을 봉출력의 함수로 생산하였는 바 허용 봉내압은 봉출력의 증가에 따라 감소하였다. 한편, 본 연구에서 구한 허용 봉내압을 봉내압 설계 기준으로 적용하면 핵연료봉 압력 검증을 위한 현행 설계절차를 단순화시킨다. 왜냐하면, 봉내압이 계통압력을 초과할 경우 각각의 주어진 시간 및 축 방향 지점에서 핵연료봉 갭 증가를 계산해야 하는 현행 설계절차가 불필요하기 때문이다.

  • PDF

Full-scale study of wind loads on roof tiles and felt underlay and comparisons with design data

  • Robertson, A.P.;Hoxey, R.P.;Rideout, N.M.;Freathy, P.
    • Wind and Structures
    • /
    • 제10권6호
    • /
    • pp.495-510
    • /
    • 2007
  • Wind pressure data have been collected on the tiled roof of a full-scale test house at Silsoe in the UK. The tiled roof was of conventional UK construction with a batten-space and bitumen-felt underlay beneath the interlocking concrete tiles. Pressures were monitored on the outer surface of selected tiles, at several locations within the batten-space, and beneath the underlay. Data were collected both with and without ventilator tiles installed on the roof. Little information appears to exist on the share of wind load between tiles and underlays which creates uncertainty in the design of both components. The present study has found that for the critical design case of maximum uplifts it would be appropriate to assign 85% of the net roof load to the tiles and 15% to the underlay when an internal pressure coefficient of -0.3 is used, and to assign 60% to the tiles and 50% to the underlay when an internal pressure coefficient of +0.2 is assumed (an element of design conservatism is inherent in the apparent 110% net loading indicated by the latter pair of percentage values). These findings indicate that compared with loads implied by BS 6399-2, UK design loads for underlay are currently conservative by 25% whilst tile loads are unconservative by around 20% in ridge and general regions and by around 45% in edge regions on average over roof slopes of $15^{\circ}-60^{\circ}$.

초음속 디퓨져 시동 과정에 관한 수치 모사; 초기 진공도에 따른 디퓨져 내부 충격파 구조의 발달 과정 (Numerical simulation on starting transients in supersonic exhaust diffuser; evolution of internal shock structures with different initial cell pressures)

  • 박병훈;임지환;윤응섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.46-55
    • /
    • 2005
  • For the sea-level performance test of rocket motor designed to operate in the upper atmosphere, ejectors with no induced secondary flow are generally used, which serves dual purposes of evacuating the test cell and performing as a supersonic exhaust diffuser (SED). The main concern of this research is to simulate starting transients in order to visualize evolution of internal shock structures in SED with different initial cell (vacuum chamber) pressures. RANS code with low Reynolds $k-\varepsilon$ turbulence model was employed for these computations. Numerical results were compared with the pressure measurements previously performed [Proceedings of 2004 Annual Conference, KIMST], and showed good agreements with pressure-time history of measured data. In the case of low vacuum chamber pressure, abrupt impingement of the under-expanded supersonic jet from the nozzle onto the diffuser wall was observed, whereas initial impingement point was located downstream and moved slowly upstream in the case of non-vacuum chamber pressure. In spite of initially dissimilar evolution of shock structures, iso-mach contour revealed that the steady shock structures had little difference except the location of flow separation and normal shock.

  • PDF

Buckling of aboveground oil storage tanks under internal pressure

  • Yoshida, Shoichi
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.131-144
    • /
    • 2001
  • Overpressurization can occur due to the ignition of flammable vapors existing inside aboveground oil storage tanks. Such accidents could happen more frequently than other types of accident. In the tank design, when the internal pressure increases, the sidewall-to-roof joint is expected to fail before failure occurs in the sidewall-to-bottom joint. This design concept is the socalled "frangible roof joint" introduced in API Standard 650. The major failure mode is bifurcation buckling in this case. This paper presents the bifurcation buckling pressures in both joints under internal pressure. Elastic and elastic-plastic axisymmetric shell finite element analysis was performed involving large deformation in the prebuckling state. Results show that API Standard 650 does not evaluate the frangible roof joint design conservatively in small diameter tanks.