• 제목/요약/키워드: internal heat source

검색결과 84건 처리시간 0.025초

실내발생열의 계산과 공조부하 (Calculation of Internal Heat Supplied by Human beings, Lightings and Domestic Appliances)

  • 박상동;유헌형
    • 대한설비공학회지:설비저널
    • /
    • 제13권1호
    • /
    • pp.36-47
    • /
    • 1984
  • Internal heat given off by human beings, lightings and domestic appliances is an Important factor which must be taken Into account estimate of building heating loads. This study outlines the procedures for determining the internal heat from these source and calculates the amount of internal heat added to an heat Ing spaces. This investigation shows that a family of four has a typical hourly internal heat production which averages approximately 460 Kilo- calories an hour in our country.

  • PDF

이중열원을 이용한 전기자동차용 히트펌프 시스템의 난방 성능 특성에 관한 연구 (Study on the Heating Performance Characteristics of a Heat Pump System Utilizing Air and Waste Heat Source for Electric Vehicles)

  • 우형석;안재환;오명수;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.180-186
    • /
    • 2013
  • An electric vehicle is an environment-friendly automobile which does not emit any tailpipe pollutant. In a conventional vehicle with an internal combustion engine, the internal cabin of the vehicle is usually heated using waste heat from the engine. However, for an electric vehicle, an alternative solution for heating is required because it does not have a combustion engine. Recently, a heat pump system which is widely used for residential heating due to its higher efficiency has been studied for its use as a heating system in electric vehicles. In this study, a heat pump system utilizing air source and waste heat source from electric devices was investigated experimentally. The performance of the heat pump system was measured by varying the mass flow rate ratio. The experimental results show that the heating capacity and COP in the dual heat source heat pump were increased by 20.9% and 8.6%, respectively, from those of the air-source heat pump.

Heat source control intelligent system for heat treatment process

  • Lee, JeongHoon;Cho, InHee
    • International journal of advanced smart convergence
    • /
    • 제11권4호
    • /
    • pp.28-40
    • /
    • 2022
  • Although precise temperature control in the heat treatment process is a key factor in process reliability, there are many cases where there is no separate heat source control optimization system in the field. To solve this problem, the program monitors the temperature data according to the heat source change through sensor communication in a recursive method based on multiple variables that affect the process, and the target heat source value and the actual heat treatment heat source to match the internal air temperature and material temperature. A control optimization system was constructed. Through this study, the error rate between the target temperature and the atmosphere (material surface) temperature of around 10.7% with the existing heat source control method was improved to an improved result of around 0.1% using a process optimization algorithm and system.

가정용 열병합 발전을 위한 스털링 엔진의 열원 온도 및 냉각수 유량에 따른 성능 실험 (Performance Measurements of A Stirling Engine for Household Micro Combined Heat and Power with Heat Source Temperatures and Cooling Flow Rates)

  • 심규호;김민기;이윤표;장선준
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2015
  • A Beta-type Stirling engine is developed and tested on the operation stability and cycle performance. The flow rate for cooling water ranges from 300 to 1500 ml/min, while the temperature of heat source changes from 300 to $500^{\circ}C$. The internal pressure, working temperatures, and operation speed are measured and the engine performance is estimated from them. In the experiment, the rise in the temperature of heat source reduces internal pressure but increases operation speed, and overall, enhances the power output. The faster coolant flow rate contributes to the high temperature limit for stable operation, the cycle efficiency due to the alleviated thermal expansion of power piston, and the heat input to the engine, respectively. The experimental Stirling engine showed the maximum power output of 12.1 W and the cycle efficiency of 3.0 % when the cooling flow is 900 ml/min and the heat source temperature is $500^{\circ}C$.

Disturbance due to internal heat source in thermoelastic solid using dual phase lag model

  • Ailawalia, Praveen;Singla, Amit
    • Structural Engineering and Mechanics
    • /
    • 제56권3호
    • /
    • pp.341-354
    • /
    • 2015
  • The dual-phase lag heat transfer model is employed to study the problem of isotropic generalized thermoelastic medium with internal heat source. The normal mode analysis is used to obtain the exact expressions for displacement components, force stress and temperature distribution. The variations of the considered variables through the horizontal distance are illustrated graphically. The results are discussed and depicted graphically.

건축물 용도별 내부 발열부하에 따른 수열원, 지열원 및 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 (Comparative Analysis of Energy Performance of Hydrothermal, Geothermal Source and Hybrid Heat Pump System According to Internal Heat Load for Office, School and Smart Farm)

  • 박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, comparative analysis of energy performance in Taebaek city, a test area, by applying hydrothermal, geothermal source and hybrid heat pump system to office, school and smart farms with different internal heat loads. The conclusion is as follows. In the load characteristics by use of buildings, it was found that office had a large cooling load compared to heating load, school had a large heating load compared to cooling load, and smart farm had only cooling load year-round. Performance analysis of the heat pump system in office shows that the cooling COP of the hydrothermal source is 5.12% and the heating COP is 3.22% lower based on the geothermal source, the cooling COP of the hybrid is 0.41% higher, and the heating COP is the difference in performance appeared sparsely. The performance analysis of the heat pump system in school showed that the cooling COP of the hydrothermal source was 10.44% and the heating COP 3.22% lower based on the geothermal source, and the performance difference between the hybrid cooling and heating COP was insignificant. Heat pump system performance analysis in smart farm only occurred with cooling load. Based on geothermal sources, the cooling COP of the hydrothermal source was 46% and the cooling COP of the hybrid was 19.65%, respectively.

열전지의 열원 연소에 따른 전류집전체 열변형에 관한 연구 (A Study on the Thermal Deformation of Current Collectors by Burning Heat Pellets in Thermal Batteries)

  • 지현진;김종명;김영철;조성백
    • 한국군사과학기술학회지
    • /
    • 제15권4호
    • /
    • pp.527-534
    • /
    • 2012
  • Thermal batteries are primary batteries that use molten salts as an electrolyte and employ an internal pyrotechnic source to heat the battery stack to operating temperatures, typically between 450 and $550^{\circ}C$. The unit cell of thermal batteries consists of an anode, an electrolyte, a cathode, a heat pellet and a current collector. The heat source for such batteries is typically heat pellets based on $Fe/KClO_4$. The elevated temperature by combustion of heat pellet is supposed to cause a flatness non-uniformity, buckling, with a lateral extension diameter of current collector. This paper mainly focused on the combustion and buckling model of current collector to simulate the effect of heat source. Mechanical stresses in the current collector caused by thermal stress is a critical design consideration of thermal batteries because the internal short circuit could be occurred.

열화상 비파괴 검사법을 이용한 도로포장 결함 검출 (Detecting of the defects of pavement of a road by using infrared thermography)

  • 심준기;김기현
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.69-76
    • /
    • 2015
  • The purpose of this paper is to find an limitation to detect the defect of damaged asphalt pavement structures for infrared thermography. We use heat source of a natural light to detect the defect efficiently. The heat source was applied to the asphalt specimens. Four asphalt specimens were used: one was the asphalt containing depth of 1cm internal timber, two was the asphalt containing depth of 2cm internal void, Three was the asphalt containing depth of 3cm internal timber and four was not the asphalt containing internal timber. It was found that the depth of 3cm internal timber could be detected by this method. In addition, we used the image processing to make the damage zone displayed clear in the image obtained from the thermographic operation.

무공해자동차용 R134a 히트펌프 시스템의 난방성능 향상에 관한 실험적 연구 (Experimental Study on the Heating Performance Improvement of R134a Heat Pump System for Zero Emission Vehicles)

  • 이대웅
    • 설비공학논문집
    • /
    • 제26권6호
    • /
    • pp.257-262
    • /
    • 2014
  • This paper describes an experimental study for heating performance that can be used in R-134a automobile heat pump systems. The heat pump system is widely studied for heating system in zero-emission vehicles to attain both the small power consumption and the effective heating of the cabin. This paper presents the experimental results of the influence on heating capacity and coefficient of performance of heat pump system. Tests were performed with different sizes of internal and external heat exchangers, and refrigerant flow rate was also considered in two-way flow devices. In addition, the heat, air, and water sources with the heat pump system were examined. The experimental results with the heat pump system were used to analyze the impact on performances. The best combination of performance was A-inside heat exchanger, B-outside heat exchanger, and B-flow device, respectively. In addition, a water heat-source was found to give roughly 40% of better performance than an air heat-source heat pump system.

이산화탄소를 사용한 수열원 히트펌프 시스템의 성능 특성에 관한 실험적 연구 (A Study on the Performance Characteristics of Water Heat Source Heat Pump System using CO2 Refrigerant)

  • 장근선;강희정;김영재
    • 한국산학기술학회논문지
    • /
    • 제12권8호
    • /
    • pp.3366-3373
    • /
    • 2011
  • 본 논문에서는 $CO_2$ 냉매를 적용하는 수열원 히트펌프 시스템의 성능특성에 관하여 실험적으로 연구하였다. 냉매충진량, 전자팽창밸브 개도, 압축기 주파수, 내부열교환기의 유무 등 다양한 운전변수에 따라 냉방, 난방성능 및 COP 특성을 분석하였다. 실험결과는 2200g의 냉매충진량, 26%의 전자팽창밸브 개도비율에서 최고의 COP 곡선을 나타내고 있고 압축기 주파수의 증가에 따라 냉방능력은 증가하나 난방능력은 감소하는 것으로 나타났다. 이 시스템의 경우 내부열교환기를 포함할 경우 내부열교환기가 없을 경우에 비해 약 4%의 냉방 COP 증가되었고 난방 COP는 약 0.89%감소로 성능변화가 거의 나타나지 않았다.