• 제목/요약/키워드: internal flow interaction

검색결과 87건 처리시간 0.025초

PIV시스템을 이용한 왕복동형 압축기 밸브시트 내의 내부유동측정 및 가시화 (Internal Flow Measurement and Visualization of Inside Valve Sheet of a Reciprocating Compressor Using a PIV System)

  • 박종호;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.99-102
    • /
    • 2003
  • PIV(Particle Image Velocimetry)was used to visualize the interaction of reed valve of the reciprocating compressor. The valve is the key part which governs the efficiency, noise and reliability of the compressor, so the development of analytical model about valve performance is necessary. As the valve reed is opened and closed by pressure pulsation, the flow characteristic of the refrigerant passing the valve is very important. In the present study, a circular disk with inclination is assumed to be the valve reed of a reciprocating compressor, The mean velocity shows the vortical characteristic of this flow. It is found that the back flow is affected by the height of reed valve of reciprocating compressor.

  • PDF

초음속 불완전 팽창 난류 제트 유동에 관한 수치적 연구 (Numerical Analysis for Under- or Over- Expanded Supersonic Turbulence Jet Flow)

  • 김재수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.85-89
    • /
    • 1999
  • Numerical Analysis has been done for the supersonic off-design jet flow due to the pressure difference between the jet and the ambient fluid. The difference of pressure generates an oblique shock or an expansion wave at the nozzle exit, The waves reflect repeatedly at the center axis and on the sonic surface in the shear layer, and the pressure difference is resolved across these waves interacted with the turbulence mixing layer. In this paper, the axi-symmetric Navier-Stokes equation has been used with two equation $k-{\varepsilon}$ turbulence closure model. The second order TVD scheme with flux limiters, based on the flux vector split by the smooth eigenvalue split, has been used to capture internal shocks and other discontinuities. The correction term for the compressible flow and the damping function are used in the turbulence model. Numerical calculations have been done to analyze the off-design jet flow due to the pressure difference. The variation of pressure along the flow axis is compared with an experimental result and other numerical result. The characteristics of the interaction between the shock cell and the turbulence mixing layer have been analyzed.

  • PDF

택시통행패턴에 따른 광주시 기능지역 분석 (Functional Areas of Kwang-ju City through Analysis of the Taxi-flow Pattern)

  • 김영기
    • 대한교통학회지
    • /
    • 제6권2호
    • /
    • pp.35-48
    • /
    • 1988
  • Amongst various analytic methods of internal structure of city, the factor analysis method which uses O-D matrix data has some merits and characteristics compared to other methods. 1) It is possible to find one certain interaction and flow pattern between traffic zones with in a city through reanalyzing O-D data which is too complex to grasp specific meaning or pattern of flow systems. 2) It can be easily visualized the traffic flow pattern by using adequate graphic techniques, and also can clarify the functional areas whose interaction linkages are significantly strong enough between each other. In this study, the taxi traffic O-D data between 42 traffic zones in Kwang-ju city was reanalyzied by varimax rotated factor analysis methods. As a result, four factors that have significant level factor loading (over 0.5 ) and factor score (over 1.0) were sorted out. so to speak four different functional areas were clarified in Kwang-ju city, of the West, the East, the south, and the North functional areas whose interaction linkages are significantly strong enough between each other. In the study, the taxi traffic O-D data between 42 traffic zones in Kwang-ju city was reanalyzied by varimax rotated factor analysis methods. As a result, four factors that have significant level factor loading (over 0.5) and factor score 9over 1.0) were sorted out. so to speak four different functional areas were clarified in Kwang-ju city, of the West, the East, the South, and the North functional area, then these four functional areas are almost coincided with citizen's general conception of community division and administrative district. Accordingly the factor analysis methods using traffic data seems to proved to be very accurate and useful analytic instruments for analyzing flow pattern and clarifying functional areas of city, and believed to provide basic informations and criteria for practical urban land use planning and transportation planning.

  • PDF

투과성해안구조물의 소상파 및 내부수위변동에 관한 수치모델링 (Numerical modeling of wave run-up and internal setup on and in permeable coastal structures)

  • 남인식;윤한삼;김종욱;류청로
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.172-179
    • /
    • 2001
  • A numelical model has been developed for the permeable coastal structures to simulate hydraulic characteristics on the permeable slopes, which interact with internal flow field of the structures. The model includes hydraulics in the porous medium. Numerical model was calibrated using hydraulic model experiments performed in 2-D wave flume in the Institute of Orean Hydraulics in PKNU. Good agreement were obtained with the model which employed inertia resistance term than with the conventional model, PBREAK.

  • PDF

LES를 이용한 Pseudo-Shock Waves의 가시화 (Numerical Visualization of the Pseudo-Shock Waves using LES)

  • ;;김희동
    • 한국가시화정보학회지
    • /
    • 제13권3호
    • /
    • pp.29-34
    • /
    • 2015
  • The interaction between a normal shock wave and a boundary layer along a wall surface in internal compressible flows causes a very complicated flow. This interaction region containing shock train and mixing region is called as pseudo-shock waves. Pseudo-shock waves in the divergent part of a rectangular nozzle have been investigated by using large-eddy simulation (LES). LES studies have been done for the complex flow phenomena of three-dimensional pseudo-shock waves. The LES results have been validated against experimental wall-pressure measurements. The LES results are in good agreement with experimental results. Pseudo-shock length and corner separation have been studied in three-dimensional LES model. Comparison of centerline pressure measurement and 3D visualization measurement has been discussed for the corner separation position. It has been concluded that the pseudo-shock length should be measured by using 3D visualization measurement.

Fluid-Structure Interaction Study on Diffuser Pump With a Two-Way Coupling Method

  • Xu, Huan;Liu, Houlin;Tan, Minggao;Cui, Jianbao
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권2호
    • /
    • pp.87-93
    • /
    • 2013
  • In order to study the effect of the fluid-structure interaction (FSI) on the simulation results, the external characteristics and internal flow features of a diffuser pump were analyzed with a two-way flow solid coupling method. And the static and dynamic structure analysis of the blade was also caculated with the FEA method. The steady flow field is based on Reynolds Averaged N-S equations with standard $k-{\varepsilon}$ turbulent model, the unsteady flow field is based on the large eddy simulation, and the structure response is based on elastic transient structural dynamic equation. The results showed that the effect of FSI on the head prediction based on CFD really exists. At the same radius, the van mises stress on the nodes closed shroud and hub was larger than other nodes. A large deformation region existed near inlet side at the middle of blades. The strength of impeller satisfied the strength requirement with static stress analysis based on the fourth strength theory. The dynamic stress varied periodically with the impeller rotating. It was also found that the fundamental frequency of the dynamic stress is the rotating frequency and its harmonic frequency. The frequency of maximum stress amplitude at node 1626 was 7 times of the rotating frequency. The frequency of maximum stress amplitude at node 2328 was 14 times of the rotating frequency. No matter strength failure or fatigue failure, the root of blades near shroud is the key region to analyse.

SMART 유동혼합헤더집합체의 동수력 질량 특성 고찰 (Investigation of Hydrodynamic Mass Characteristic for Flow Mixing Header Assembly in SMART)

  • 이규만;안광현;이강헌;이재선
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.30-36
    • /
    • 2020
  • In SMART, the flow mixing header assembly (FMHA) is used to mix the coolant flowing into the reactor core to maintain a uniform temperature. The FMHA is designed to have enough stiffness so the resonance with reactor internal structures does not occurs during the pipe break and the seismic accidents. Since the gap between the FMHA and the core support barrel assembly is very narrow compared with the diameter of FMHA, the hydrodynamic mass effect acting on the FMHA is not negligible. Therefore the hydrodynamic mass characteristics on the FMHA are investigated to consider the fluid and structure interaction effects. The result of modal analysis for the dry and underwater conditions, the natural frequency of primary vibration mode for the horizontal direction is reduced from 136.67 Hz to 43.76 Hz. Also the result of frequency response spectrum seismic analysis for the dry and underwater conditions, the maximum equivalent stress are increased from 13.89 MPa to 40.23 MPa. Therefore, reactor internal structures located in underwater condition shall consider carefully the hydrodynamic mass effects even though they have sufficient stiffness required for performing its functions under the dry condition.

교반탱크에서 베플 형상의 영향에 관한 수치 해석적 연구 (A Numerical Analysis on Effect of Baffles in a Stirred Vessel)

  • 염상훈;이석순
    • 항공우주시스템공학회지
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2019
  • 교반기에서의 유동 특성은 광범위한 산업 분야에서 매우 유용하다. 일반적으로 교반되는 용기에서의 유동 패턴, 전력 소비 및 혼합 시간은 임펠러의 설계뿐만 아니라 용기 형상 및 내부 구조에 달려 있다. 본 연구에서는 베플 형상과 임펠러의 상호 작용에 의해 생성되는 불안정하고 비정상상태의 복잡한 유동 특성 분석을 ANSYS FLUENT LES 난류 모델을 사용하여 수행하였다. Axial Flow 와 Radial Flow 두 가지 타입의 회전 임펠러와 3가지 베플의 형상 사이의 상호 작용과 영향을 전산유체역학(CFD)으로 예측 비교함으로써 교반 시 임펠러와 베플 주변에서의 유동 특성과 혼합 유동장에서 상대적으로 효율적인 경향을 보이는 설계 모델을 검증할 수 있었다.

EFFECT OF VALVE TIMING AND LIFT ON FLOW AND MIXING CHARACTERISTICS OF A CAI ENGINE

  • Kim, J.N.;Kim, H.Y.;Yoon, S.S.;Sa, S.D.;Kim, W.T.
    • International Journal of Automotive Technology
    • /
    • 제8권6호
    • /
    • pp.687-696
    • /
    • 2007
  • To increase the reliability of auto-ignition in CAI engines, the thermodynamic properties of intake flow is often controlled using recycled exhaust gases, called internal EGR. Because of the internal EGR influence on the overall thermodynamic properties and mixing quality of the gases that affect the subsequent combustion behavior, optimizing the intake and exhaust valve timing for the EGR is important to achieve the reliable auto-ignition and high thermal efficiency. In the present study, fully 3D numerical simulations were carried out to predict the mixing characteristics and flow field inside the cylinder as a function of valve timing. The 3D unsteady Eulerian-Lagrangian two-phase model was used to account for the interaction between the intake air and remaining internal EGR during the under-lap operation while varying three major parameters: the intake valve(IV) and exhaust valve(EV) timings and intake valve lift(IVL). Computational results showed that the largest EVC retardation, as in A6, yielded the optimal mixing of both EGR and fuel. The IV timing had little effect on the mixing quality. However, the IV timing variation caused backflow from the cylinder to the intake port. With respect to reduction of heat loss due to backflow, the case in B6 was considered to present the optimal operating condition. With the variation of the intake valve lift, the A1 case yielded the minimum amount of backflow. The best mixing was delivered when the lift height was at a minimum of 2 mm.

성층화된 유체 내에서 내부파와 표면파의 파형 변화 실험을 위한 수치적 연구 (Numerical Study for Experiment on Wave Pattern of Internal Wave and Surface Wave in Stratified Fluid)

  • 이주한;김관우;백광준;구원철;김영규
    • 한국해양공학회지
    • /
    • 제33권3호
    • /
    • pp.236-244
    • /
    • 2019
  • Internal waves occur at the interface between two layers caused by a seawater density difference. The internal waves generated by a body moving in a two-layer fluid are also related to the generation of surface waves because of their interaction. In these complex flow phenomena, the experimental measurements and experimental set-up for the wave patterns of the internal waves and surface waves are very difficult to perform in a laboratory. Therefore, studies have mainly been carried out using numerical analysis. However, model tests are needed to evaluate the accuracy of numerical models. In this study, the various experimental conditions were evaluated using CFD simulations before experiments to measure the wave patterns of the internal waves and surface waves in a stratified two-layer fluid. The numerical simulation conditions included variations in the densities of the fluids, depth of the two-layer fluid, and moving speed of the underwater body.