• Title/Summary/Keyword: internal feedback

Search Result 239, Processing Time 0.032 seconds

Needs for Development of IT-based Nutritional Management Program for Women with Gestational Diabetes Mellitus (IT-기반의 임신성 당뇨병 영양관리 프로그램 개발을 위한 요구도 조사)

  • Han, Chan-Jung;Lim, Sun-Young;Oh, Eunsuk;Choi, Yoon-Hee;Yoon, Kun-Ho;Lee, Jin-Hee
    • Korean Journal of Community Nutrition
    • /
    • v.22 no.3
    • /
    • pp.207-217
    • /
    • 2017
  • Objectives: The aim of this study was to examine self-management status, nutritional knowledge, barrier factors in dietary management and needs of nutritional management program for women with Gestational Diabetes Mellitus (GDM). Methods: A total of 100 women with GDM were recruited from secondary and tertiary hospitals in Seoul. The questionnaire composed of general characteristics, status of self-management, dietary habits, nutrition knowledge, barrier factors in dietary management, needs for nutrition information contents and nutritional management programs. Data were collected by a self-administered questionnaire. All data were statistically analyzed using student's t-test and chi-square test using SAS 9.3. Results: About 35% of the subjects reported that they practiced medical nutrition and exercise therapy for GDM control. The main sources of nutrition information were 'internet (50.0%)' and 'expert advice (45.0%)'. More than 70% of the subjects experienced nutrition education. The mean score of nutrition knowledge was 7.5 point out of 10, and only about half of the subjects were reported to be correctly aware of some questions such as 'the cause of ketosis', 'the goal of nutrition management for GDM', 'the importance of sugar restriction on breakfast'. The major obstructive factors in dietary management were 'eating more than planned when dining out', 'finding the appropriate menu when dining out'. The preferred nutrition information contents in developing management program were 'nutritional information of food', 'recommended food by major nutrients', 'the relationship between blood glucose and food', 'tips on menu selection at eating out'. The subjects reported that they need management program such as 'example of menu by calorie prescription', 'recommended weight gain guide', 'meal recording and dietary assessment', 'expert recommendation', 'sharing know-how'. Conclusions: Based on the results of this study, it is necessary to develop a program that provide personalized information by identifying the individual characteristics of the subjects and expert feedback function through various information and nutrition information contents that can be used in real life.

Dynamic-Response-Free SMPS Using a New High-Resolution DPWM Generator Based on Switched-Capacitor Delay Technique (Switched-Capacitor 지연 기법의 새로운 고해상도 DPWM 발생기를 이용한 Dynamic-Response-Free SMPS)

  • Lim, Ji-Hoon;Park, Young-Kyun;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • In this paper, we suggest the dynamic-response-free SMPS using a new high-resolution DPWM generator based on switched-capacitor delay technique. In the proposed system, duty ratio of DPWM is controlled by voltage slope of an internal capacitor using switched-capacitor delay technique. In the proposed circuit, it is possible to track output voltage by controlling current of the internal capacitor of the DPWM generator through comparison between the feedback voltage and the reference voltage. Therefore the proposed circuit is not restricted by the dynamic-response characteristic which is a problem in the existing SMPS using the closed-loop control method. In addition, it has great advantage that ringing phenomenon due to overshoot/undershoot does not appear on output voltage. The proposed circuit can operate at switching frequencies of 1MHz~10MHz using internal operating frequency of 100 MHz. The maximum current of the core circuit is 2.7 mA and the total current of the entire circuit including output buffer is 15 mA at the switching frequency of 10 MHz. The proposed circuit has DPWM duty ratio resolution of 0.125 %. It can accommodate load current up to 1 A. The maximum ripple of output voltage is 8 mV. To verify operation of the proposed circuit, we carried out simulation with Dongbu Hitek BCD $0.35{\mu}m$ technology parameter.

Plasma Etching Process based on Real-time Monitoring of Radical Density and Substrate Temperature

  • Takeda, K.;Fukunaga, Y.;Tsutsumi, T.;Ishikawa, K.;Kondo, H.;Sekine, M.;Hori, M.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.93-93
    • /
    • 2016
  • Large scale integrated circuits (LSIs) has been improved by the shrinkage of the circuit dimensions. The smaller chip sizes and increase in circuit density require the miniaturization of the line-width and space between metal interconnections. Therefore, an extreme precise control of the critical dimension and pattern profile is necessary to fabricate next generation nano-electronics devices. The pattern profile control of plasma etching with an accuracy of sub-nanometer must be achieved. To realize the etching process which achieves the problem, understanding of the etching mechanism and precise control of the process based on the real-time monitoring of internal plasma parameters such as etching species density, surface temperature of substrate, etc. are very important. For instance, it is known that the etched profiles of organic low dielectric (low-k) films are sensitive to the substrate temperature and density ratio of H and N atoms in the H2/N2 plasma [1]. In this study, we introduced a feedback control of actual substrate temperature and radical density ratio monitored in real time. And then the dependence of etch rates and profiles of organic films have been evaluated based on the substrate temperatures. In this study, organic low-k films were etched by a dual frequency capacitively coupled plasma employing the mixture of H2/N2 gases. A 100-MHz power was supplied to an upper electrode for plasma generation. The Si substrate was electrostatically chucked to a lower electrode biased by supplying a 2-MHz power. To investigate the effects of H and N radical on the etching profile of organic low-k films, absolute H and N atom densities were measured by vacuum ultraviolet absorption spectroscopy [2]. Moreover, using the optical fiber-type low-coherence interferometer [3], substrate temperature has been measured in real time during etching process. From the measurement results, the temperature raised rapidly just after plasma ignition and was gradually saturated. The temporal change of substrate temperature is a crucial issue to control of surface reactions of reactive species. Therefore, by the intervals of on-off of the plasma discharge, the substrate temperature was maintained within ${\pm}1.5^{\circ}C$ from the set value. As a result, the temperatures were kept within $3^{\circ}C$ during the etching process. Then, we etched organic films with line-and-space pattern using this system. The cross-sections of the organic films etched for 50 s with the substrate temperatures at $20^{\circ}C$ and $100^{\circ}C$ were observed by SEM. From the results, they were different in the sidewall profile. It suggests that the reactions on the sidewalls changed according to the substrate temperature. The precise substrate temperature control method with real-time temperature monitoring and intermittent plasma generation was suggested to contribute on realization of fine pattern etching.

  • PDF

Development of Anti-windup Techniques for Cascade Control System (다단제어용 안티 와인드업 기술 개발)

  • Bae, Jeong Eun;Kim, Kyeong Hoon;Chu, Syng Chul;Heo, Jaepil;Lim, Sanghun;Sung, Su Whan
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.430-437
    • /
    • 2020
  • In this research, the anti-windup techniques for the cascade control system are newly developed. Cascade control system has an additional internal feedback control loop to reject disturbances better than the conventional control system. Remarkable difference between the conventional single-loop control system and the cascade control system is the interaction that the controller output saturation of the secondary control loop strongly affects the integral action of the primary control loop. In industry, local back calculation anti-windup method has been mainly used for each controller without considering the interaction between the two controllers. But it cannot eliminate the integral-windup of the primary controller originated from the saturation of the secondary controller output. To solve the problem, the two anti-windup techniques of the cascade conditional integration and the cascade back calculation are proposed in this research by extending the local anti-windup techniques for the single-loop control system to the cascade control system. Simulation confirmed that the proposed methods can effectively remove the integral windup of the primary controller caused by the saturation of the secondary controller output and show good control performances for various types of processes and controllers. If the reliability of the proposed methods is proved through the applications to real processes in the future, they would highly contribute to improving the control performances of the cascade control system in industry.

The Usefulness of Pressure-regulated Volume Control(PRVC) Mode in Mechanically Ventilated Patients with Unstable Respiratory Mechanics (기계 호흡 중 불안정한 호흡역학을 보인 환자에서 압력조절용적조정양식(Pressure-regulated Volume Control Mode)의 효용)

  • Sohn, Jang-Won;Koh, Youn-Suck;Lim, Chae-Man;Shim, Tae-Sun;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1318-1325
    • /
    • 1997
  • Background : Since the late 1960s, mechanical ventilation has been accomplished primarily using volume controlled ventilation(VCV). While VCV allows a set tidal volume to be guaranteed, VCV could bring about excessive airway pressures that may be lead to barotrauma in the patients with acute lung injury. With the increment of knowledge related to ventilator-induced lung injury, pressure controlled ventilation(PCV) has been frequently applied to these patients. But, PCV has a disadvantage of variable tidal volume delivery as pulmonary impedance changes. Since the concept of combining the positive attributes of VCV and PCV(dual control ventilation, DCV) was described firstly in 1992, a few DCV modes were introduced. Pressure-regulated volume control(PRVC) mode, a kind of DCV, is pressure-limited, time-cycled ventilation that uses tidal volume as a feedback control for continuously adjusting the pressure limit However, no clinical studies were published on the efficacy of PRVC until now. 'This investigation studied the efficacy of PRVC in the patients with unstable respiratory mechanics. Methods : The subjects were 8 mechanically ventilated patients(M : F=6 : 2, $56{\pm}26$ years) who showed unstable respiratory mechanics, which was defined by the coefficients of variation of peak inspiratory pressure for 15 minutes greater than 10% under VCV, or the coefficients of variation of tidal volume greater than 10% under PCV. The study was consisited of 3 modes application with VCV, PCV and PRVC for 15 minutes by random order. To obtain same tidal volume, inspiratory pressure setting was adjusted in PCV. Respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). Results : 1) Mean tidal volumes($V_T$) in each mode were not different(VCV, $431{\pm}102ml$ ; PCV, $417{\pm}99ml$ ; PRVC, $414{\pm}97ml$) 2) The coefficient of variation(CV) of $V_T$ were $5.2{\pm}3.9%$ in VCV, $15.2{\pm}7.5%$ in PCV and $19.3{\pm}10.0%$ in PRVC. The CV of $V_T$ in PCV and PRVC were significantly greater than that in VCV(p<0.01). 3) Mean peak inspiratory pressure(PIP) in VCV($31.0{\pm}6.9cm$ $H_2O$) was higher than PIP in PCV($26.0{\pm}6.5cm$ $H_2O$) or PRVC($27.0{\pm}6.4cm$ $H_2O$)(p<0.05). 4) The CV of PIP were $13.9{\pm}3.7%$ in VCV, $4.9{\pm}2.6%$ in PVC and $12.2{\pm}7.0%$ in PRVC. The CV of PIP in VCV and PRVC were greater than that in PCV(p<0.01). Conclusions : Because of wide fluctuations of VT and PIP, PRVC mode did not seem to have advantages compared to VCV or PCV in the patients with unstable respiratory mechanics.

  • PDF

Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel (휘도기반 터널내 운전자 적정조명시스템 개발 연구)

  • Lee, Mi-Ae;Kim, Yeon-Hwa;Han, Seung-Hun;Kim, Ji-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

Dynamic Model for Open Innovation Network (개방형 혁신 네트워크의 동태적 모형)

  • Park, Chulsoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.40 no.1
    • /
    • pp.5-19
    • /
    • 2015
  • Literatures on open innovation have two major limitations. First, either on a firm level or on an industry level did they analyze the open innovation issues. The results of a firm's innovation can be diffused through the whole network and the firm can learn back from the network knowledge. Prior literatures did not consider the feedback loop among firms and network in which the firms are involved. Second, most open innovation research had a static perspective on firm's innovation performance. Since the diffusion, spill-over and learning among network members are involved over time, the open innovation is intrinsically dynamic. From the dynamic perspective, we can appreciate the fundamental attributes of the open innovation network which involves diverse firms, research institutes, and universities. In order to overcome the limitations, we suggest a dynamic model for open innovation network. We build an agent-based model which consists of heterogeneous firms. The firms are connected through a scale-free network which is formed by preferential attachment. Through the diverse scenario of simulation, we collect massive data on the firm level and analyze them both on firm and industry level. From the analysis, we found that, on industry level, the overall performance of open innovation increases as the internal research capability, absorptive capacity, and learning curve coefficient increase. Noticeably, as the deprecation rate of knowledge increases, the variability of knowledge increases. From the firm level analysis, we found that the industry-level variables had a significant effect on the firm's innovation performance lasting through all the time, whereas the firm-level variables had only on the early phase of innovation.

Test Time Reduction for BIST by Parallel Divide-and-Conquer Method (분할 및 병렬 처리 방법에 의한 BIST의 테스트 시간 감소)

  • Choe, Byeong-Gu;Kim, Dong-Uk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.6
    • /
    • pp.322-329
    • /
    • 2000
  • BIST(Built-in Self Test) has been considered as the most promising DFT(design-for-test) scheme for the present and future test strategy. The most serious problem in applying BIST(Built-in Self Test) into a large circuit is the excessive increase in test time. This paper is focused on this problem. We proposed a new BIST construction scheme which uses a parallel divide-and-conquer method. The circuit division is performed with respect to some internal nodes called test points. The test points are selected by considering the nodal connectivity of the circuit rather than the testability of each node. The test patterns are generated by only one linear feedback shift register(LFSR) and they are shared by all the divided circuits. Thus, the test for each divided circuit is performed in parallel. Test responses are collected from the test point as well as the primary outputs. Even though the divide-and-conquer scheme is used and test patterns are generated in one LFSR, the proposed scheme does not lose its pseudo-exhaustive property. We proposed a selection procedure to find the test points and it was implemented with C/C++ language. Several example circuits were applied to this procedure and the results showed that test time was reduced upto 1/2151 but the increase in the hardware overhead or the delay increase was not much high. Because the proposed scheme showed a tendency that the increasing rates in hardware overhead and delay overhead were less than that in test time reduction as the size of circuit increases, it is expected to be used efficiently for large circuits as VLSI and ULSI.

  • PDF

A SD approach to the ecosystems of Korean venture business

  • Lee, Myoung-Ho;Hoon Huh
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.50-59
    • /
    • 2001
  • Since 1998, government-led Korean venture business boom now proceeds into the stage of market-oriented venture business growth. At such a moment, this research is to clarify the relations between the Critical Success Factors of Korean venture businesses, based on domestic and foreign literature surveys and inquiry surveys over domestic venture capitalists. This research starts from the necessity to overcome the limits of the existing researches by uni-dimensional Korean venture businesses and to manifest the multi-dimensional relations between the success factors from the various viewpoints. And this research adopts System-Dynamics methodology to manifest and utilize relations among those factors, avoiding the existing metrical approaches. This research can be called a new approach to the current ecosystems of Korean venture in which whether venture businesses in Korea succeed is considered to depend on the list on the stock market. For this, this research implemented verification analysis through the simulations of each factor at various levels to build causality map which clarifies the causality of success factors of venture businesses through the System-Dynamics methodology and to utilize it as a way of support to decision-making of venture businesses. This research will be able to suggest the reactions depending on various internal and external situations. This research tried to manifest the causality map of each factor on the basis of inquiry surveys and literature surveys to clarify Feedback among each factor by the SD methodology and simulate it. This research will be a basis to establish the chance to bolster up the still fragile probing research into success factors of substructure of venture businesses through the suggestion of possibility as an efficient analysis framework via the verification of SD methodology and the utilization of results of this research.

  • PDF

Digit-serial VLSI Architecture for Lifting-based Discrete Wavelet Transform (리프팅 기반 이산 웨이블렛 변환의 디지트 시리얼 VLSI 구조)

  • Ryu, Donghoon;Park, Taegeun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.157-165
    • /
    • 2013
  • In this paper, efficient digit-serial VLSI architecture for 1D (9,7) lifting-based discrete wavelet transform (DWT) filter has been proposed. The proposed architecture computes the DWT in digit basis, so that the required hardware is reduced. Also, the multiplication is replaced with the shift and add operation to minimize the hardware requirement. Bit allocation for input, output, and the internal data has been determined by analyzing the PSNR. We have carefully designed the data feedback latency not to degrade the performance in the recursive folded scheduling. The proposed digit-serial architecture requires small amount of hardware but achieve 100% of hardware utilization, so we try to optimize the tradeoffs between the hardware cost and the performance. The proposed architecture has been designed and verified by VerilogHDL and synthesized by Synopsys Design Compiler with a DongbuHitek $0.18{\mu}m$ STD cell library. The maximum operating frequency is 330MHz with 3,770 gates in equivalent two input NAND gates.