• Title/Summary/Keyword: internal control method

Search Result 1,204, Processing Time 0.024 seconds

The immunohistochemical studies of Opaesan on Gastric ulcer induced by HCl-aspirin in rat (오패산(烏貝散)이 HCl-aspirin으로 유발(誘發)된 백서(白鼠)의 위궤양(胃潰瘍)에 미치는 면역조직화학적(免疫組織化學的) 연구(硏究))

  • Han, Sang-Soon;Han, Sang-Won;Park, Soon-Dal
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.185-207
    • /
    • 1998
  • In order to study the immunohistochemical effects of Opae-san on gastric ulcer induced by HCl-aspirin in rats, experiments were done by oral administration and measure histological features of ulcer lesion, scaning electron microscopic appearance, the changes of numbers of parietal cells, chief cells, gastrin and somatostatin-immunoreactive cells. The obtained results are as follows: 1. Ulcerative lesions were numerously detected in control groups especially in junction of cardiac-fundic gastric mucosa and histologically very severe injury to gastric epithelium were observed too but in the Opae-san administrated groups, no gross lesion of ulcer were detected and histologically minor injury of gastric mucosa were observed. Most slight injuries to gastric mucosa were observed in 5 days after treatment. 2. The numbers of parietal cells were remarkably increased in control group but in Opae-san administrated groups appeared significant decrease compared to control groups. Most remarkably decrease of the numbers of parietal cells compared to control groups were observed in 5 days after treatment. 3. The numbers of chief cells were remarkably decreased in control group but in Opae-san administrated groups appeared significant increase compared to control groups. Most remarkably increase of the numbers of chief cells compared to control groups were observed in 5 days after treatment. 4. The numbers of gastrin-immunoreactive cells were remarkably decreased in control group but in Opae-san administrated groups appeared significant increase compared to control groups. Most remarkably decrease of the numbers of gastrin-immunoreactive cells compared to control groups were observed in 5 days after treatment. 5. The numbers of somatostatin-immunoreactive cells were remarkably decreased in control group but in Opae-san administrated groups appeared significant increase compared to control groups. Most remarkably decrease of the numbers of somatostatin-immunoreactive cells compared to control groups were observed in 5 days after treatment. 6. Scaning electron microscopically, severe denude and degeneration of gastric mucosa were observed in control groups but in Opae-san administrated groups the lesions were remarkably decreased compared to control groups.

  • PDF

Improvement of Transient Performance of Synchronous Generator using Feedforward Controller (피드포워드 제어기를 사용한 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.

Flow Measurement and Control by Time-Based Method

  • Chang, Young-Chul;Kim, No-Hyu;Kim, Yong-Cheol
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.115-116
    • /
    • 2002
  • This study aimed to investigate flow measurement by using a 'bucket and stop-watch' method of flow measurement. Most flow measurement systems measure pressure or other fluid properties to infer flow rate, though time is a variable which can be easily and very accurately measured. The main principle behind the method was to fill up a reservoir until a set pressure had been reached. This reservoir would then be emptied and the cycle would repeat itself. The prototype was designed to control flow rate using the method. It made use of computer control with an analogue digital converter and fast acting solenoid valves which controlled the flow into a reservoir. Reservoirs were available with internal diameter of 1mm up to 5.5mm to cope with a range of flow rate.

  • PDF

The A Study on the Characteristics of Internal Control System's Operation and Accounting Information Quality - Focused on Hong Kong Public Company (내부시스템 운영과 회계정보 질의 특성에 대한 연구 - 홍콩 GEM상장 기업을 중심으로)

  • Kim, Dong-Il;Xu, Meng-Jun
    • Journal of Digital Convergence
    • /
    • v.18 no.1
    • /
    • pp.121-127
    • /
    • 2020
  • This study analyzed through GEM-listed companies for verifying the interrelationship between positive and negative impacts on accounting information GEM-listed companies, whether venture firms operate the internal control operation system stably. Hong Kong's GEM listed company is a securities market similar to Korea's KOSDAQ market. To analyzing this study, used regression analysis method through internal control index to evaluate the operation of internal control system and discretionary accruals to evaluate the quality of accounting information. In this study, because profit adjustments used to realize through discretionary accruals, so analyzed using the modified Jones model to check whether the management deliberately transformed the company to realize future profits. In the empirical analysis, the correlation between the internal control index and the discretionary accruals to assess the quality of accounting information was able to find highly correlated. This study can provide useful guidance for evaluating the form and value of profit management of venture firms in the future, also would expect to help understand the financial environment of emerging venture firms.

Serum cardiac troponin I concentrations in clinically normal and Dirofilaria immitis infected Korean Jindo dogs

  • Hwang, Soo-Hyen;Park, Hyung-Jin;Seo, Kyoung-Won;Lee, Sang-Eun;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.1
    • /
    • pp.53-54
    • /
    • 2014
  • This study was conducted to determine the serum cardiac troponin I (cTnI) concentrations in clinically normal (uninfected) Korean Jindo dogs and those infected with Dirofilaria (D.) immitis. Forty Korean Jindo dogs (22 females, 18 males) were obtained from two kennels in the Boryeong area of Chungnam Province and the Daejeon area, Korea. Significantly higher cTnI concentrations were observed in D. immitis-infected dogs than clinically normal dogs. cTnI testing in addition to thoracic radiography, echocardiography, and electrocardiography shows promise as an additional method for diagnosis of heartworm infection.

Modeling of Stochastic Properties of Internal Heat Generation of an Office Building for Slab Cooling Storage (사무소건물의 슬래브축냉을 위한 내부발열부하의 확률적 성상 모델화)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.836-842
    • /
    • 2011
  • It has been shown that the air-conditioning system with slab cooling storage is effective in cutting peak load and utilizing nighttime electric power. The stochastic properties of internal heat generation which has great influence on the cooling load are examined in this paper. Based on the measured cooling load and electric power consumption in an office building with slab cooling storage, stochastic time series models to simulate these random processes are investigated. Furthermore, a calculated result by an optimal control method of thermal analysis taking into account the internal heat is compared with the measured cooling load.

Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement (양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석)

  • Park, Cheol-Woo;Park, Young-Hoon;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

A Case-Control Study on Blood Lipids as a Risk Factor of Stroke (뇌졸중 위험지표로서의 혈중 지질에 대한 환자;대조군 연구)

  • Kim, Jung-Hyun;Kang, Kyung-Won;Yu, Byeong-Chan;Choi, Sun-Mi;Baek, Hye-Ki;Lim, Seung-Min;An, Jung-Jo;Seol, In-Chan;Kim, Yoon-Sik
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.830-837
    • /
    • 2007
  • Background and purpose : Stroke is one of the most deadly diseases and a leading cause of disability. Lipids confer an increased risk for cardiovascular morbidity and mortality. In spite of many studies on the relationship between stroke and lipids, their relationship is not clear. This study was undertaken to determine whether lipids were associated with stroke. Method : We compared the components of blood lipids between stroke patients group (n=217,Cases), non-stroke control group (n=160, Controls) and healthy control group without hypertension, diabetes mellitus, ischemic heart disease, or hyperlipidemia (n=140, Normals). These data were statically analyzed by general linear models and binary logistic regression analysis to get each adjusted odds ratio. Result : The results were as follows. The blood levels of total cholesterol (T-Chol), triglyceride (TG) and low density lipoprotein cholesterol (LDL-Chol) were significantly higher in patients of ischemic stroke, while the blood levels of T-Chol and LDL-Chol were significantly lower, and the blood levels of TG significantly higher in patients of hemorrhagic stroke. The blood level of high density lipoprotein cholesterol (HDL-Chol) was significantly lower in all cases. Conclusion : These results suggest that high TG and low HDL-Chol may be risk factors of hemorrhagic stroke and ischemic stroke, high T-Chol and LDL-Chol may be risk factors of ischemic stroke, and low T-Chol and LDL-Chol may be risk factors of hemorrhagic stroke in Koreans.

  • PDF

Two-Degree-of-Freedom Control of Two-Mass Resonant System using $H_{\infty}$ Filer ($H_{\infty}$필터를 이용한 2관성 공진계의 2자유도제어)

  • Kim, Jin-Soo;Kang, Seok-Jin;Shin, Jae-Hwa;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.515-517
    • /
    • 1997
  • In the industrial motor drive system, a shaft torsional vibration is often generated when a motor and a load are connected with a flexible shaft. This paper treats the vibration suppression control of such a system. In this paper, two-degree-of-freedom(TDOF) control of the two-mass resonant system using the $H_{\infty}$ filter is proposed. TDOF control method satisfies the command following property and the internal stability at the same. The $H_{\infty}$ filter is robust in noise and disturbance. Simulation results show the validity of the proposed control method.

  • PDF

Development of the Switching Mode Conversion Type Pulse Charger for the Lead Battery of Solar Cell Generator Equipment by Fly-Back Converter Method (플라이백 컨버터방법에 의한 태양광발전설비의 납축전지 스위칭모드 전환형 펄스충전기 개발)

  • Shin, Choon-Shik;An, Young-Joo;Kim, Dong-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.20-26
    • /
    • 2009
  • In this paper, the switching mode conversion type pulse charger by fly-back converter method for lead battery of the solar cell generator equipment is proposed. And we propose the control circuit and design method of insulated switching mode convert type pulse charger by fly-back convert method in the lead battery. The proposed system can minimize the current consumption by digital pulse. Also the proposed system can generate the constant 10[KHz] frequency, transmit the signal with main control system in the power control system. And it supervises the state of lead battery using one chip micro processor. The proposed the switching mode conversion type pulse charger by the fly-back converter method can charge fast and stabilize lead battery with nominal value 12[V], 20[AH]. Also we propose the design procedure of the power control circuit for turn ratio of fly-back inductor and determining method of values such as the charging current, bulk current, partial current, over current value and fixed charging voltage. The experiment results for the voltage and current wave for partial, bulk, over and fixed charging period show the good charging effect and performance. And the PCB and internal coupling diagram of the switching mode conversion type pulse charger by fly-back converter method is presented.