• Title/Summary/Keyword: internal consistency

Search Result 1,010, Processing Time 0.034 seconds

Cross-cultural Validation of Instruments Measuring Health Beliefs about Colorectal Cancer Screening among Korean Americans

  • Lee, Shin-Young;Lee, Eunice E.
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.1
    • /
    • pp.129-138
    • /
    • 2015
  • Purpose: The purpose of this study was to report the instrument modification and validation processes to make existing health belief model scales culturally appropriate for Korean Americans (KAs) regarding colorectal cancer (CRC) screening utilization. Methods: Instrument translation, individual interviews using cognitive interviewing, and expert reviews were conducted during the instrument modification phase, and a pilot test and a cross-sectional survey were conducted during the instrument validation phase. Data analyses of the cross-sectional survey included internal consistency and construct validity using exploratory and confirmatory factor analysis. Results: The main issues identified during the instrument modification phase were (a) cultural and linguistic translation issues and (b) newly developed items reflecting Korean cultural barriers. Cross-sectional survey analyses during the instrument validation phase revealed that all scales demonstrate good internal consistency reliability (Cronbach's alpha=.72~.88). Exploratory factor analysis showed that susceptibility and severity loaded on the same factor, which may indicate a threat variable. Items with low factor loadings in the confirmatory factor analysis may relate to (a) lack of knowledge about fecal occult blood testing and (b) multiple dimensions of the subscales. Conclusion: Methodological, sequential processes of instrument modification and validation, including translation, individual interviews, expert reviews, pilot testing and a cross-sectional survey, were provided in this study. The findings indicate that existing instruments need to be examined for CRC screening research involving KAs.

Evaluation and Application of the Korean Version of the Sexuality Attitudes and Beliefs Survey for Nurses (한국형 간호사의 성 태도와 신념 조사도구(Sexuality Attitudes and Beliefs Survey)의 적합성 평가 및 적용)

  • Kim, Hae Won;Jung, Yeon Yi;Park, Seungmi
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.6
    • /
    • pp.889-897
    • /
    • 2012
  • Purpose: This study was conducted to evaluate the validity and reliability of the Korean version of the Sexuality Attitudes and Beliefs Survey (SABS) and to assess SABS for Korean nurses. Methods: The Korean version of SABS was developed through forward-backward translation techniques. Internal consistency reliability and construct validity using confirmatory factor analysis were conducted using PASW+ PC Win (18.0) and AMOS (18.0). Data were collected from 567 nurses who worked in one of six general hospitals across the country. Results: The Korean version of SABS showed a reliable internal consistency with Cronbach's ${\alpha}$ of subscales ranging from .59 to .73. Factor loadings of the 10 items of three subscales ranged from .38 to .83. The three subscales model were validated by confirmatory factor analysis (GFI>.97, RMSEA<.05). Sexuality attitudes and beliefs for Korean nurses were more negative than that of European or American nurses. The SABS scores for Korean nurses were significantly different according to age, marriage, education, clinical experiences, and feeling about sexuality. Conclusion: The Korean version of SABS has satisfactory construct validity and reliability to measure Korean nurses' attitudes and belief toward sexuality. Education is essential to enhance importance and self-efficacy and to relieve barriers to addressing patients' sexuality.

Validity and Reliability of the Nurses' Self-Concept Instrument (NSCI) for Registered Nurses in Long-term Care Hospitals (요양병원 간호사를 위한 전문직 자아개념 (Nurses' Self-Concept Instrument, NSCI) 도구의 타당도와 신뢰도)

  • Ryu, Jung Mi;Kim, Myoung Soo
    • Research in Community and Public Health Nursing
    • /
    • v.28 no.4
    • /
    • pp.366-374
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity and reliability of the Korean Version of the Nurses' Self-Concept Instrument (NSCI) geriatric hospital nurses in Korea. Methods: Bilingual nursing professionals performed translation and back-translation. Reliability and validity of the content and construction of the instrument were confirmed. Internal consistency reliability was determined. Construction and concurrent validity were verified using factor analysis and correlation coefficients. Results: The total 14 items for the Korean version of the Nurses' Self-Concept Instrument (NSCI) were retained through item analysis. In explanatory factor analysis, four subcategories were proposed with their names of each factor: 'Leadership', 'Staff relation', 'Knowledge', and 'Care'. The four factors accounted for 78.81% of the variances. The Cronbach's ${\alpha}$ regarding internal consistency were .77~.91 for the NSCI subscales. Correlation among four subcategories ranged .62~.84. Conclusion: The findings show that the Korean version of the Nurses' Self-Concept Instrument is reliable and valid for measuring professional Self-Concept of geriatric hospital nurses in Korea.

Development on the Questionnaire of Cold-Heat Pattern Identification Based on Usual Symptoms: Reliability and validation Study (평소 증상 기반 한열변증 설문지의 신뢰도 및 타당도 연구)

  • Bae, Kwang Ho;Jang, Eun Su;Park, Kihyun;Lee, Youngseop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.5
    • /
    • pp.341-346
    • /
    • 2018
  • The aims of this study were to evaluate the reliability and validity of the cold and heat pattern identification questionnaire (CHPIQ). From July 2015 to December 2015, 120 participants, university faculties, filled out CHPIQ by the way of self-reporting. Then two Korean medical doctors independently diagnosed them whether they belonged to cold pattern (CP) or not, and heat pattern (HP) or not. We evaluated the internal consistency using Cronbach's alpha coefficient, and the validity using the sensitivity and specificity through receiver operating characteristic-curve. The internal consistency (Cronbach's alpha coefficient) showed 0.754 (CP) and 0.753 (HP). The area under the curve was recorded with 0.884 (CP) and 0.786 (HP). The agreements between CHPIQ and experts were 82.8% (CP) and 72.9% (HP). The sensitivities showed 0.707 (CP) and 0.719 (HP), and the specificities were 0.935 (CP) and 0.736 (HP). This study suggests that CHPIQ is a reliable and valid instrument for estimating cold-heat pattern identification.

Service quality, satisfaction, and behavioral intention in home delivered meals program

  • Joung, Hyun-Woo;Kim, Hak-Seon;Yuan, Jingxue Jessica;Huffman, Lynn
    • Nutrition Research and Practice
    • /
    • v.5 no.2
    • /
    • pp.163-168
    • /
    • 2011
  • This study was conducted to evaluate recipients' perception of service quality, satisfaction, and behavioral intention in home delivered meals program in the US. Out of 398 questionnaires, 265 (66.6%) were collected, and 209 questionnaires (52.5%) were used for the statistical analysis. A Confirmatory Factor Analysis (CFA) with a maximum likelihood was first conducted to estimate the measurement model by verifying the underlying structure of constructs. The level of internal consistency in each construct was acceptable, with Cronbach's alpha estimates ranging from 0.7 to 0.94. All of the composite reliabilities of the constructs were over the cutoff value of 0.50, ensuring adequate internal consistency of multiple items for each construct. As a second step, a Meals-On-Wheels (MOW) recipient perception model was estimated. The model's fit as indicated by these indexes was satisfactory and path coefficients were analyzed. Two paths between (1) volunteer issues and behavioral intention and (2) responsiveness and behavioral intention were not significant. The path for predicting a positive relationship between food quality and satisfaction was supported. The results show that having high food quality may create recipient satisfaction. The findings suggest that food quality and responsiveness are significant predictors of positive satisfaction. Moreover, satisfied recipients have positive behavioral intention toward MOW programs.

Development and Psychometric Evaluation of the Resuscitation Self-efficacy Scale for Nurses

  • Roh, Young Sook;Issenberg, S. Barry;Chung, Hyun Soo;Kim, So Sun
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.7
    • /
    • pp.1079-1086
    • /
    • 2012
  • Purpose: The purpose of this study was to develop and evaluate psychometric properties of the instrument, Resuscitation Self-Efficacy Scale for nurses. Methods: This was a methodological study for instrument development and psychometric testing. The initial item pool derived from literature review and experts resulted in 30 items linked to resuscitation self-efficacy. A convenience sample of 509 Korean nurses from eleven academic teaching hospitals participated in a survey to examine psychometric properties of the scale. To examine construct validity, exploratory factor analysis and known-group comparison were used. Cronbach's coefficient alpha was used to determine the scale's internal consistency reliability. Results: The final scale included 17 items with four-component structure termed 'Recognition', 'Debriefing and recording', 'Responding and rescuing', and 'Reporting'. These four factors accounted for 57.5% of the variance. Each subscale and the total scale demonstrated satisfactory internal consistency: .82; .88; .87; .83; and .91 respectively. Experienced nurses reported significantly higher self-efficacy mean scores in both total and subscales compared to new graduate nurses. Conclusion: The Resuscitation Self-Efficacy Scale for nurses yields reliable and valid results in appraising the level of resuscitation self-efficacy for Korean nurses. Further study is needed to test and refine the scale.

Evidence of the need for Security National Competency Standards Training (경호 NCS 교육의 필요성에 대한 실증분석)

  • Choi, Jeong-Il;Jang, Ye-Jin
    • Convergence Security Journal
    • /
    • v.16 no.6_2
    • /
    • pp.33-42
    • /
    • 2016
  • This study was set up hypothesis "NCS recognition ➩ NCS training needs ➩ Performance of the NCS training". The survey was conducted to explore the need for Security-related NCS education at university and awareness of the NCS for Security Studies students. Results of analyzing the internal consistency, this study showed that ensure internal consistency is calculated Chronbach's Alpha coefficient of more than 0.8. Validation of the survey was investigated by secured Convergent validity and discriminant validity among the variables calculated all over the reference value. This study showed that the model is appropriate with results using the structural equation modeling to validate the research model The correlation analysis of this hypothesis was very high as calculated the standardization factor 0.726 and 0.870 for each relationship by hypothesis testing results.

Reliability and Validity of the Korean Translation of the Pediatric Evaluation of Disability Inventory in School-Aged Children With Cerebral Palsy

  • Kim, Won-Ho;Park, Eun-Young;Park, So-Yeon
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.69-76
    • /
    • 2010
  • The purposes of this study were to examine the reliability and validity of Korean translation of Pediatric Evaluation of Disability Inventory (PEDI-K) in school-aged children with cerebral palsy (CP). The PEDI-K, Functional Independence Measure for Children (WeeFIM) and Gross Motor Function Classification System (GMIFCS) were completed in 104 school-aged children with CP by therapists. The internal consistency of the PEDI-K was calculated by Cronbach's alpha (${\alpha}$) for assessing reliability. Concurrent validity was evaluated by correlation with the subsets of WeeFIM. Discriminant validity was assessed by comparing GMFCS levels with tests of the PEDI-K. The results showed that internal consistency was good (Cronbach's ${\alpha}$ ranged from .97~.98). Concurrent validity was demonstrated. The correlation with WeeFIM was high in the Functional Skills (self-care, r=.74~.94; mobility, r=.59~.91; social function, r=.65~.93) and in the Caregiver Assistance (self-care, r=.75~.94; mobility, r=.63~.90; social function, r=.78~.96). Discriminant validity was demonstrated on significant decreases in domain scores with increasing GMFCS levels. Reliability and validity have been demonstrated on the PEDI-K. This study extends usage of PEDI-K in clinical activities and research.

Development of a Questionnaire to Measure Resilience in Children with Chronic Diseases (만성질환아의 극복력(Resilience) 측정도구 개발)

  • Kim, Dong-Hee;Yoo, Il-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.2
    • /
    • pp.236-246
    • /
    • 2010
  • Purpose: The purpose of this study was to develop and evaluate a Korean questionnaire to measure resilience in children with chronic illness. Methods: Item construction was drawn from an extensive review of the literature, existing questionnaires and interviews with parents. Content validity was tested by experts. To further refine the questionnaire and test its reliability and validity, data were collected from the 202 children with asthma, diabetes mellitus or nephrotic syndrome. Corrected items were used to total correlation coefficient and test-retest reliability. Questionnaire testing was conducted using factor analysis, Cronbach's $\alpha$, and correlation coefficients. Validity of the questionnaire was tested using internal consistency, construct validity, and criterion-related validity. Results: Components of the questionnaire were in three domains; interpersonal characteristics, characteristics of coping, and intrapersonal characteristics. Factor analysis is showed five factors; positive self-understanding, self-reliance, resourcefulness, perception of positive family relationships, and intimacy. The questionnaire showed a high internal consistency. A significant positive correlation with the Numerical Rating Score and negative correlation with the Child Depression Inventory support the validity of the questionnaire. Conclusion: This instrument demonstrated high reliability and validity. Therefore, this instrument can contribute to the evaluation of resilience of chronically ill children and to any subsequent intervention as well as to develop a theory for resilience.

The Validity and Reliability of a Korean Version of the Summary of Diabetes Self-Care Activities Questionnaire for Older Patients with Type 2 Diabetes (제2형 당뇨노인을 대상으로 한 당뇨 자가 관리 측정도구(The Summary of Diabetes Self-Care Activities Questionnaire, SDSCA) 한국어 버전의 타당도와 신뢰도 검증)

  • Chang, Sun-Ju;Song, Mi-Soon
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.2
    • /
    • pp.235-244
    • /
    • 2009
  • Purpose: This research was carried out to evaluate the validity and reliability of the Korean version of the Summary of Diabetes Self-Care Activities Questionnaire (SDSCA) for Korean older adults with type 2 diabetes. Methods: Translation and back-translation were performed to develop the Korean version of the SDSCA. Then the Korean version SDSCA was applied to a sample of 112 older adults who had participated in diabetes self management education in Seoul. The internal consistency and the test-retest reliability were examined to test the reliability. Factor analysis was used to examine the construct validity. Results: The internal consistency measured with Cronbach's alpha was .77 and the total test-retest reliability was .68 with items ranging from .21 to 1.00. As the result of the factor analysis, six factors -foot care, diet, exercise, blood sugar test, medication, and smoking- were revealed as the original instrument subcategories. These six factors explained 81.17% of total variance. Conclusion: The reliability and validity of the Korean version SDSCA Questionnaire was supported for use in older patients with type 2 diabetes in Korea.

  • PDF