• Title/Summary/Keyword: internal bond test

Search Result 40, Processing Time 0.031 seconds

A Study on the Fracture Behavior of Composite Laminated T-Joints Using AE (AE를 이용한 복합재료 T 조인트부의 파괴거동에 관한 연구)

  • Kim, J.H.;Ahn, B.W.;Sa, J.W.;Park, B.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.277-287
    • /
    • 1999
  • Quasi-static tests such as monotonic tension and loading/unloading tension were performed to investigate the bond characteristics and the failure processes for the T-joint specimens made from fiber/epoxy composite material. Two types of specimens, each consists of two components, e. g. skin and frame. were manufactured by co-curing and secondary bonding. During the monotonic tension test, AE instrument was used to predict AE signal at the initial and middle stage of the damage propagation. The damage initiation and progression were monitored optically using m (Charge Coupled Device) camera. And the internal crack front profile was examined using ultrasonic C-scan. The results indicate that the loads representing the abrupt increase of the AE signal are within the error range of 5 percent comparing to the loads shown in the load-time curve. Also it is shown that the initiation of crack occurred in the noodle region for both co-cured and secondarily bonded specimen. The final failure occurred in the noodle region for the co-cured specimen. but at the skin/frame termination point for the secondarily bonded specimen. Based on the results, it was found that two kinds of specimen show different failure modes depending on the manufacturing methods.

  • PDF

Effects of the Treated Chemicals on the Flexual and Physical Properties of Fire Retardant Treated Particleboards (내화처리(耐火處理) 파티클 보오드의 휨강도(强度)와 물리적(物理的) 성질(性質)에 미치는 약제(藥劑)의 영향(影響))

  • Lee, Phil-Woo;Kwon, Jin-Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.39-48
    • /
    • 1983
  • This research was performed to investigate the manufacturing possibility of the particleboard treated with commercial fire retardant chemicals. Laboratory test boards at this investigation were made from particles treated by soaking into 5, 10, 15, and 20 percent concentration solutions of ammonium sulfate and Minalith before resin was applied. According to the results, MOR (modulus of repture) and MOE (modulus of elasticity) in flexure exceeded type 100 (100 kgf/$cm^2$, $1.5{\times}10^4\;kgf/cm^2$) of the Korean Industrial Standard (KS F 3104). Except for 15 and 20 percent chemicals concentrations of Minalith, every internal bond stress values met type 100 (1.5 kgf/$cm^2$) of KS F 3104. However thickness swelling values of fire retardant treated particleboards were not reached in the Standard (12%).

  • PDF

Studies on Manufacture of Thin Composite Panel for Substitute Use of Plywood (I) - On the Optimum Manufacturing Condition of Composites - (합판대용(合板代用) 박판상(薄板狀) 복합재(複合材) 제조(製造)에 관(關)한 연구(硏究) (I) - 복합재(複合材) 제조(製造)의 최적조건(最適條件)에 관(關)하여 -)

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.55-69
    • /
    • 1995
  • The primary objective of this research was to investigate optimum manufacturing condition of thin composite panels composed of sawdust, polyethylene film and polypropylene net. At the study the experiment was designed to make thin board in which sawdust offers effectiveness as core composing material, polyethylene as adhesive with added urea resin, and polypropylene as stiffness and flexibility in the composition panel. 100 types of thin composite panels were manufactured according to press-lam and mat-forming process of various hot pressing conditions(pressure, temperature and time). They were tested and compared with control boards on bending properties(MOR, MOE, SPL, WML), internal bond strength, thickness swelling, linear expansion and water absorption. At the same time the visual inspections of each types of panels were accomplished. The physical and mechanical properties of composite types passed by visual inspection were analyzed by Tukey's studentized range test. From the statistical analysis, the optimum manufacturing condition of thin composite panels were selected. Compared with two manufacturing processes, mat-forming process performed better than press-lam process in all tested properties. The optimum manufacturing conditions resulted from the experiment and statistical analysis were able to determine as following: the press temperature was shown the most good result at 130$^{\circ}C$ in mat forming process and 140$^{\circ}C$ press lam process, the press time 4 min in both processes, but the press pressure was 25-10kg/$cm^2$ in mat forming and 15k/$cm^2$ press lam process.

  • PDF

Micromorphological Features of MDF Fiber Surface and Adhesives Distribution in MDF (MDF 섬유(纖維)의 표면(表面) 형태(形態)와 접착제(接着劑)의 분포(分布) 관찰(觀察))

  • Kim, Jae-Woo;Park, Sang-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.61-70
    • /
    • 1996
  • 침엽수재(針葉樹材)(Radiata pine, Pinus radiata)MDF와 활엽수재(闊葉樹材)(Rubber wood, Hevea brasiliensis)MDF 각 1종을 대상으로 MDF를 제조하기 전 원료(原料) 섬유(纖維)의 미세(微細) 구조(構造) 및 내부결합력 시험 후 MDF의 파괴면(破壞面)에서 섬유표면(纖維表面)에 접착제(接着劑)가 도포(塗布)된 형태를 주사전자현미경(走査電子顯微鏡)으로 관찰하였다. 원료 섬유는 침(針) 활엽수재(闊葉樹材) 모두 fiber twisting 및 shrinkage fold 등이 관찰되었다. 침엽수재(針葉樹材)의 경우는 유연벽공부(有緣壁孔部)에서 유연벽공(有緣壁孔)이 없는 부분에 비하여 shrinkage fold의 발생 빈도가 낮고 표면(表面) 박리(剝離)는 가도관(假導管) 중 벽공이 없는 부분에서 관찰되었다. 활엽수재(闊葉樹材) 목섬유(木纖維)는 침엽수재(針葉樹材)와 마찬가지로 shrinkage fold가 관찰되었으나 표면(表面) 박리(剝離)는 거의 관찰되지 않았다. 활엽수(闊葉樹) 섬유(纖維)에서는 벽공의 유무에 따른 shrinkage fold의 차이(差異)가 거의 관찰되지 않았는데 이는 목섬유(木纖維)가 침엽수(針葉樹) 가도관(假導管)보다 작은 단벽공(單壁孔)을 갖기 때문으로 생각된다. 또 방사유세포(放射柔細胞)와 가도관(假導管) 및 목섬유(木纖維)의 박리(剝離) 부분(部分)에는 융기부(隆起部)가 관찰되었다. 내부결합력 시험후 나타난 파괴면을 통하여 접착제 분포를 관찰한 결과 거의 모든 섬유(纖維)들이 접착제(接着劑)로 둘러싸여 있었으며 섬유(纖維)간 접착형태(接着形態)도 매우 다양하였다. 침활엽수재(針闊葉樹材)간에 강도(强度)의 차이는 있었지만 파괴(破壞) 형태(形態)는 큰 차이를 나타내지 않았다. 즉 침활엽수(針闊葉樹) 모두 접착층(接着層)이 아닌 섬유(纖維)에서 파괴(破壞)가 발생하였으며 섬유에서 박리(剝離)된, 세포벽(細胞壁)의 일부가 다른 섬유(纖維)의 표면(表面)에 남아있는 형태와 섬유(纖維) 표면(表面)에서 떨어져 나간 형태로 관찰되었다. 세포 구성이 단순한 침엽수(針葉樹) MDF에 비하여 유세포(柔細胞)와 도관(導管) 및 목섬유(木纖維)의 파편들이 활엽수(闊葉樹) MDF에서는 다양(多樣)하게 분포하였다.

  • PDF

Measurement of Formaldehyde Emissions during Hot-Pressing of Particleboard Bonded with Melamine-Urea-Formaldihyde Resin (요소-멜라민수지로 접착된 파티클보드의 열압동안 포름알데히드 배출량 측정)

  • Lee, Jong-Kyu;Oh, Yong-Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.65-72
    • /
    • 2004
  • A melamine-urea-formaldehyde (MUF) resin, based on 5 percent melamine addition of the resin solids weight, was synthesized in the laboratory for particleboard (PB) manufacture. Laboratory PBs were made with the MUF resin at three press times (3, 4, 5 min) and two resin application rates (6, 8 percent). Enclosed caul system was used for collecting the exhaust gases materials generated during the hot-pressing of PBs. Exhaust gases materials generated inside the enclosed caul during the hot-pressing of PBs were collected in a controlled air stream. Formaldehyde from the exhaust gases collected was determined per a chromotropic method of the National Institute of Occupational Safety and Health Method 3500. The measurement results showed that formaldehyde emissions during the hot-pressing of PB significantly increased with increasing press time, and MUF resin application rates. PB' performance test results showed that internal bond (IB) of PB made with 3-minute press time exceeded the minimum requirement for KS F 3104 PB type 8.0.

Performance of Wood-plastic Panel Made from Populus alba × glandulosa and Low Density Polyethylene (은수원사시나무와 저밀도 폴리에틸렌으로 제조된 목질플라스틱패널의 성능)

  • Kwak, Jun-Hyuk;Oh, Yong-Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.67-72
    • /
    • 2004
  • Wood/polyethylene panels were manufactured from Populus alba × glandulosa particles and low density polyethylene particles at three mixing rates, 50:50, 60:40, and 70:30. A total of 15 wood/polyethylene panels was made at 145℃ and 5 minutes hot-press time. Wood/polyethylene panels were tested for internal bond, bending, and dimensional stabilities such as thickness swell and water absorption. Panel performance data were analyzed using the SAS programing package. The test results of the wood/polyethylene panels showed that as the polyethylene mixing rates were increased, the panel property values increased. Based on panels' dimensional stabilities, the optimum wood/polyethylene mixing ratio appeared to be 60:40.

Does Brand Experience Affect Consumer's Emotional Attachments? (브랜드의 총체적 체험이 소비자-브랜드의 정서적 유대관계에 미치는 영향)

  • Lee, Jieun;Jeon, Jooeon;Yoon, Jaeyoung
    • Asia Marketing Journal
    • /
    • v.12 no.2
    • /
    • pp.53-81
    • /
    • 2010
  • Brand experience has received much attention from considerable marketing research. When consumers consume and use brands, they are exposed to various specific brand-related stimuli. These brand-related stimuli include brand identity and brand communications(e.g., colors, shapes, designs, slogans, mascots, brand characters) components. Brakus, Schmitt, and Zarantonello(2009) conceptualized brand experience as subjective and internal consumer responses evoked by brand-related stimuli. They demonstrated that brand experience can be broken down into four dimensions(sensory, affective, intellectual, and behavioral). Because experiences result from stimulations and lead to pleasurable outcomes, we expect consumers to want to repeat theses experiences. That is, brand experiences, stored in consumer memory, should affect brand loyalty. Consumers with positive experiences should be more likely to buy a brand again and less likely to buy an alternative brand(Fournier 1998; Oliver 1997). Brand attachment, one of dimensions of the consumer-brand relationship, is defined as an emotional bond to the specific brand(Thomson, MacInnis, and Park 2005). Brand attachment is target-specific bond between the consumer and the specific brand. Thus, strong attachment is attended by a rich set of schema that link the brand to the consumer. Previous researches propose that brand attachments should affect consumers' commitment to the brand. Brand experience differs from affective construct such as brand attachment. Brand attachment is based on interaction between a consumer and the brand. In contrast, brand experience occurs whenever there is a direct and indirect interaction with the brand. Furthermore, brand experience is not an emotional relationship concept. Brakus et al.(2009) suggest that brand experience may result in brand attachment. This study aims to distinguish brand experience dimensions and investigate the effects of brand experience on brand attachment and brand commitment. We test research problems with data from 265 customers having brand experiences in various product categories by using multiple regression and structural equation model. The empirical results can be summarized as follows. First, the paths from affective, behavior, and intellectual experience to the brand attachment were found to be positively significant whereas the effect of sensory experience to brand attachment was not supported. In the consumer literature, sensory experiences for consumers are often equated with aesthetic pleasure. Over time, these pleasure experiences can affect consumer satisfaction. However, sensory pleasures are not linked to attachment such as consumers' strong emotional bond(i.e., hot affect). These empirical results confirms the results of previous studies. Second, brand attachment including passion and connection influences brand commitment positively but affection does not influence brand commitment. In marketing context, consumers with brand attachment have intention to have a willingness to stay with the relationship. The results also imply that consumers' emotional attachment is characterized by a set of brand experience dimensions and consumers who are emotionally attached to the brand are committed. The findings of this research contribute to develop differences between brand experience and brand attachment and to provide practical implications on the brand experience management. Recently, many brand managers have focused on short-term view. According to this study, we suggest that effective brand experience management requires taking a long-term view of marketing decisions.

  • PDF

Material Properties of Ultra Rapid Hardening Mortar for Repairing Sewage Treatment Concrete Pipes (콘크리트 하수관거 보수용 초속경 수중불분리 모르타르의 재료적 특성)

  • Lee, Byungjae;Lee, Sunmok;Bang, Jin-wook;Kim, Yun-yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.57-62
    • /
    • 2020
  • Among the sewage pipes installed in Korea, the length of concrete pipes exceeding 20 years is 66,334 km (42.5%). Deteriorated concrete sewer pipes need to be repaired due to the leakage of internal sewage, which causes problems such as sink holes by expanding the cavity around the pipeline. In this study, we tried to apply anti-washout underwater mortar with ultra rapid hardening cement and segregation reducing agent to sewage pipe repair. As a result of the setting time test, the final set time was delayed by up to 172% by incorporating segregation reducing agent. In the test for measuring the degree of mortar segregation in water, it was measured at pH 12 or less under all mixing conditions. In addition, the suspension amount was measured to be 50 mg / l or less to satisfy the KCI-AD102 standard by incorporating a segregation reducing agent. In terms of the average value of mortar compressive strength, by incorporating segregation reducing agent, the strength of the specimens produced in air was more than 80% of that of the specimens produced in water. Conversely, the bond strengths of the specimens produced in water were measured to be higher than those of the specimens produced in air. Water resistance was evaluated by measuring water absorption and water permeability. Water absorption and water permeability were reduced by 42.6% and 36.6%, respectively, by mixing segregation reducing agent.

Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations (Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석)

  • Lee, Sang-Ik;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.222-233
    • /
    • 2007
  • One of the most important and basic test of dental restorative materials is the evaluation of microleakage into the tooth-restorative interface. There are many techniques to test microleakage, but most of them have several disadvantages. Recently developed microtomography(micro-CT) can provide the three dimensional image and information about the internal component in non-destructive way, therefore using micro-CT, it is possible to evaluate microleakage exactly in quantitative manner. The purpose of this study is to find a new method for quantitative and non-destructive evaluation of microleakage in composite resin restorations using micro-CT and to compare the new method with conventional dye penetration method. Thus, microleakages of two kinds of dentin bonding systems were evaluated with above two methods. 40 extracted sound human premolars were randomly divided into two groups consisting of 20 samples and restored accordingly. Group 1 : Class V resin restorations with $Adper^{TM}$ Singe Bond Group, 2 : Class V resin restorations with $Adper^{TM}\;Promp^{TM}$ L-pop. The $Filtek^{TM}$ Supreme was applied to the Class V cavities of all teeth. After that, 10 teeth from each group were applied to evaluation of microleakage using micro-CT, and other 10 teeth from each group were using conventional dye penetration method. The conclusions of this study were as follow : 1 Using micro-CT, Group 1 showed significantly less microleakage than Group 2 and there was statistically significant difference(p<0.01) between two groups. 2. Using conventional dye penetration method, Group 1 leaked less than Group 2 and there was statistically significant difference(p<0.01) between two groups 3. The difference between two groups is more evident in the method using micro-CT. 4. In all two methods, microleakage appeared more into the cavities to dentinal margins than enamel margins.

  • PDF

Fatigue Behavior of Prestressed Concrete Beams Using FRP Tendons (FRP 긴장재를 이용한 프리스트레스트 콘크리트 보의 피로 거동)

  • Kim, Kyoung-Nam;Park, Sang-Yeol;Kim, Chang-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.135-144
    • /
    • 2011
  • Recently, researches about fiber reinforced polymer (FRP) which has excellent durability, corrosion resistance, and tensile strength as a substitution material to steel tendon have been actively pursued. This study is performed to examine FRP tendon used prestressed beam's safety under service load. The specimen was a prestressed concrete beam with internal bonded FRP tendon. In order to compare the member fatigue capacity, a control specimen of a prestressed concrete beam with ordinary steel tendon was tested. A fatigue load was applied at a load range of 60%, 70%, and 80% of the 40% ultimate load, which was obtained though a static test. The fatigue load was applied as a 1~3 Hz sine wave with 4 point loading setup. Fatigue load with maximum 1 million cycles was applied. The specimen applied with a load ranging between 40~60% did not show a fatigue failure until 1 million cycles. However, it was found that horizontal cracks in the direction of tendons were found and bond force between the tendon and concrete was degraded as the load cycles increased. This fatigue study showed that the prestressed concrete beam using FRP tendon was safe under a fatigue load within a service load range. Fatigue strength of the specimen with FRP and steel tendon after 1 million cycles was 69.2% and 59.8% of the prestressed concrete beam's static strength, respectively.