• Title/Summary/Keyword: intermittent operation

Search Result 176, Processing Time 0.037 seconds

A Systems Engineering Approach to Multi-Physics Load Follow Simulation of the Korean APR1400 Nuclear Power Plant

  • Mahmoud, Abd El Rahman;Diab, Aya
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.1-15
    • /
    • 2020
  • Nuclear power plants in South Korea are operated to cover the baseload demand. Hence they are operated at 100% rated power and do not deploy power tracking control except for startup, shutdown, or during transients. However, as the contribution of renewable energy in the energy mix increases, load follow operation may be needed to cover the imbalance between consumption and production due to the intermittent nature of electricity produced from the conversion of wind or solar energy. Load follow operation may be quite challenging since the operators need to control the axial power distribution and core reactivity while simultaneously conducting the power maneuvering. In this paper, a systems engineering approach for multi-physics load follow simulation of APR1400 is performed. RELAP5/SCDAPSIM/MOD3.4/3DKIN multi-physics package is selected to simulate the Korean Advanced Power Reactor, APR1400, under load follow operation to reflect the impact of feedback signals on the system safety parameters. Furthermore, the systems engineering approach is adopted to identify the requirements, functions, and physical architecture to provide a set of verification and validation activities that guide this project development by linking each requirement to a validation or verification test with predefined success criteria.

Analysis and comparison of the water supply adjustment guide and a hedging rule of reservoir operation derived from mixed-integer programming for water supply operation of a multi-purpose reservoir (다목적댐의 가뭄 대비 용수공급 조정기준과 혼합 정수계획법에 의한 용수 감량 공급 기준의 비교 및 분석)

  • Jin, Youngkyu;Jeong, Taekmun;Lee, Sangho
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.6
    • /
    • pp.443-452
    • /
    • 2021
  • The authors obtained the discrete hedging rule for a reservoir's water supply operation by applying mixed-integer programming to save more water by earlier rationing of water supply for a drought period. The 'water supply adjustment guide' is the current operational method applied to the multipurpose reservoirs, and it was derived by a simulation method. Applying the two rules to the Hapcheon multipurpose dam's reservoir simulations with the inflow record from 2003 to 2018, the water supply deficit occurred for the long drought from 2015 to 2018. Especially, the no water supply or intermittent water supply persisted for the second half of 2017. The water supply adjustment guide had the 'normal water supply recovery threshold on storage,' which resulted in the water supply being unavailable in July 2017; then, the water supply suspension occurred until January 2018, when the reservoir storage was greater than the normal water supply recovery threshold. Despite the storage increasing due to the inflow of water into the reservoir, the suspension occurrence needs to be improved in practice. The current water supply adjustment guide and the discrete hedging rule for a reservoir's water supply operation are useful and realistic as the reservoir operation guide, which shows the concept of reducing water supply during the drought phase as scientific figures. However, to improve the reservoir simulation results, which do not provide any or intermittent water for several months, it is necessary to increase the current water supply reduction for drought phases.

Simulation of the Wind Power Generation System with Energy Storage System (전기저장 장치가 포함된 풍력발전 시스템에 대한 시뮬레이션)

  • Oh, Si-Doek;Lim, Hee-Sue;Seo, Seok-Ho;Kim, Ki-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.303-306
    • /
    • 2008
  • The wind power generation systems have a fluctuating or intermittent power output due to the variability of the wind speed. The amount of wind generation which can be connected to the grid without causing voltage stability problems is limited. In this study, the simulation of the wind power generation including energy storage system were performed to reduce the fluctuation of wind power output and to obtain the optimal operation planning of energy storage system.

  • PDF

Operation Strategy for a Multi-functional Storage Facility (하수저류시설 운영 전략 연구)

  • Yun, So-Young;Lim, Yoon-Dae;Oh, Jei-ll
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.959-970
    • /
    • 2011
  • The frequent occurrence of sewer flooding and the intermittent discharge of non-point pollutions into the receiving water body are emerging issues recently due to the climate change and urbanization. These problems might be solved by introducing a multifunctional storage facility. Unlike a single-purpose storage facility, a multi-purpose storage facility should be operated at an instant to meet for flood prevention, reduction of non-point pollution and/or rainwater reuse. Considering various operational combinations it is suggested that prevention of sewer flooding coupled with reduction of non-point pollution is the most effective operational strategy for a multi-functional storage facility.

Simultaneous Revascularization for Coronary Artery Stenosis and Peripheral Vascular Disease. (관상동맥 우회술과 말초 혈관 협착의 동맥 우회술의 동시 수술)

  • Song, Hyun; Lee, Eun-Sang;Yoo, Dong-Gon
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.943-946
    • /
    • 1999
  • There was no significant difference in morbidity and mortality between those that received simultaneous operation for coronary artery disease and peripheral vascular disease versus those that received coronary artery bypass graft alone. Simultaneous operation is also cost effective. A 46 year-old patient with resting chest pain and intermittent claudication was diagnosed as unstable angina and Leriche's syndrome. We performed simultaneous revascularization for coronary artery stenosis with internal mammary artery and right gastroepiploic artery and a bifurcated vascular graft interposition between in the aorta, left common iliac and right femoral arteries for Leriche's syndrome. The postoperative coronary angiogram and aortogram revealed a good patency of the arterial conduits and vascular graft. He has been followed for 12 months without any problem.

  • PDF

The Analysis of Influence on High-speed Train(KTX) ATC Signals according Sand Materials (고속차량(KTX) ATC 신호에 미치는 살사재료별 영향 분석)

  • Yun, Cha-Jung;Noh, Myoung-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.834-840
    • /
    • 2014
  • When the high speed train (KTX) departs from station in the high-speed line, intermittent on-board signal disappearance causes a hindrance of the operation punctuality. Therefore, we have a research objective to verify the causes of hindrance and to find an improvement plan. process of research, when train leaves the station, we applied sand on the rail to improve adhesive power, that sand has an effect on the ATC(Automatic Train Control) signal wave. We detected & analyzed signal waves which is came from detecting device by changing operation condition in accordance with sand material overage detection to be achieved.

A Comparative Study of Antegrade Cardioplegia Versus Retrograde Cardioplegia for Myocardial Protection during the Open Heart Surgery (순행성 관관류법과 역행성 관관류법의 임상적 비교연구)

  • 조완재
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.609-619
    • /
    • 1989
  • During aortic valve surgery, cardioplegic solution is delivered through direct cannulation of both coronary ostia. Since this approach may cause an intimal injury leading to acute dissection or late ostial stenosis, this study was undertaken to evaluate myocardial protective effect of retrograde perfusion of cardioplegia [RCSP <% RRAP] in 18 clinical cases, which were compared with antegrade perfusion of cardioplegia in 27 clinical cases. This study were investigated 1] cease and return of electromechanical activity after cardioplegia infusion 2] the myocardial temperature during operation 3] the aortic cross clamping time and total bypass time 4] frequency of DC shock for defibrillation 5] need for inotropic drugs after operation 6] electrocardiographic evidence of myocardial infarction or ventricular arrhythmia after operation 7] the enzymes activity during preoperative and postoperative period as an evaluation of myocardial ischemic injury and 8] operative mortality rate The combination of retrograde cardioplegia and topical cooling with ice slush yielded promptly hypothermia of myocardium and shorter aortic cross-clamping time compared with antegrade cardioplegia [P < 0.05]. The temperature of the interventricular septum was maintained below 20oC by continuous perfusion or intermittent perfusion of cold blood cardioplegia and other results were no statistically significant difference between the two methods [P >0.05]. This technique provides clear operative field and avoids some serious complications which are caused by coronary ostial cannulation. These results suggested that the retrograde perfusion of cardioplegia is a simple, safe, and effective means of myocardial protection during open heart surgery.

  • PDF

Experimental study on flame behavior within a porous ceramic burner (다공 세라믹 버너 내부의 화염 거동에 관한 실험)

  • Im, In-Gwon;Jeong, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.518-524
    • /
    • 1997
  • Experimental studies on combustion phenomena within a porous ceramic burner are reported. Main interest of the present work is to investigate fundamental flame behaviors and their effects on the burner operation. Due to high thermal capacity of the porous ceramic materials, the response of flame to burning condition changes is slow and thus to have a stabilized flame is quite difficult and takes much time. It is found that the temperature profile obtained at downstream of the flame zone is not much sensitive to the movement of flame and the speed of flame movement is less than 0.1 mm/sec for the conditions tested. With the premixed LPG/air flame imbedded within the porous ceramic burner, stable combustion regions and unstable combustion regions leading to blowoff or flashback phenomena are observed and mapped on flow velocity versus equivalence ratio diagram. For the development of burner operation technique which is more practical and safe, intermittent burning technique, where the fuel or/and air is supplied to the burner intermittently, is proposed as one of the flame control methods for the porous ceramic burner and tested in this study. Through the experiment, it is realized that the proposed method is acceptable in respect to burner performance and give much flexibility in the operation of porous ceramic burner.

A Case of Giant Papillary Thyroid Carcinoma Resection with Massive Intraoperative Bleeding (술 중 대량 출혈을 동반한 거대 갑상선유두상암종 절제술 1례)

  • Kim, Seok Hyun;Jung, Jae Hwan;Sung, Eui Suk;Lee, Jin Choon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.33 no.1
    • /
    • pp.85-89
    • /
    • 2017
  • A 62-year-old female patient had goiter for twenty years. She visited out-patient clinic with a hoarse voice and intermittent breathing difficulties. About protruding 15cm sized mass located the anterior neck and right vocal cord paralysis was observed. Preoperative CT scan was strongly suspected of thyroid gland cancer and cervical lymph node metastasis. Therefore, fine needle aspiration test was performed and surgical treatment was planned with the histopathologic results (papillary thyroid carcinoma). Surgery was performed with total thyroidectomy, bilateral cervical lymph node dissection, and right selective nodal lymph node dissection (level II-V). During operation right thyroid seemed to be adherent to surrounding tissue and the blood vessels were extremely engorged. There was hypotensive crisis because of intraoperative excessive bleeding. However it was managed by repetitive transfusion. The operation was completed without abnormalities. She underwent 4 times of bleeding control operation due to postoperative bleeding. After complications were improved, we are currently undergoing out-patient follow up without morbidity.

Esophageal Atresia with Double Tracheoesophageal Fistula - A Case Report - (근,원위부 기관 식도루를 가진 식도 폐쇄증 - 1예 보고 -)

  • Nam, So-Hyun;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.14 no.1
    • /
    • pp.88-93
    • /
    • 2008
  • Esophageal atresia with double tracheoesophageal fistula is a very rare anomaly and is difficulty to diagnose preoperatively. We treated a full term baby with esophageal atresia with double tracheoesophageal fistula. At the first operation, only the distal tracheoesophageal fistula was identified and ligated. When the upper esophageal pouch was opened, intermittent air leakages in sequence with positive bagging were noticed. However, intraoperative bronchoscopy did not identify a fistula in the proximal pouch, and the operation was completed with end to end anastomosis of the esophagus. On the $7^{th}$ postoperative day, esophagography showed another tracheoesophageal fistula proximal to the esophageal anastomosis. A wire was placed in the fistula preoperatively under bronchoscopy. At the 2nd operation through the same thoracotomy incision the proximal fistula was identified and ligated. On the $12^{th}$ postoperative day, esophagography showed neither stricture nor leakage.

  • PDF