• 제목/요약/키워드: intermittent inspection

검색결과 16건 처리시간 0.018초

LPI차량에서 CKPS불량으로 주행 중 간헐적인 엔진부조 현상의 고장진단 (Case Study of Intermittent Engine Hesitation Fault Diagnosis By CKPS Fault)

  • 김성모
    • 한국생산제조학회지
    • /
    • 제23권6호
    • /
    • pp.624-629
    • /
    • 2014
  • The purpose of this study is to carry out the task of engine hesitation which occurred intermittently in driving due to the defective CKPS of LPI vehicles. As the result of the wrong data from the equipment of D-logger, the signal error of CKPS caused the engine hesitation. We performed a study in the followings to analyze and investigate the cause effectively. First, we have investigated the control wiring harness and connector pin contact defect inspection. Second, we have inspected the defection of CKPS separately. From this study, it was found that the engine hesitation were caused by the bad durability and we have showed how to diagnosis the fault of the engine hesitation intermittently while driving. Therefore, it is determined that we have to improve the durability of the CKPS through a strict quality control and to increase the reliability.

국내 음용수의 안전성 (Safety of Drinking Water in Korea)

  • 권숙표
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.1-20
    • /
    • 1997
  • The present standard of drinking water quality is not reached to the guidelines of WHO and US EPA recommended. The appraisal of safety is not appropriate by the results of intermittent and limitted analysis. 45 items of drinking water quality are regulated in the Korean standard and 9 items for inspection designated by Seoul City. This report is the results of analysis of the water quality in the water stations of Seoul which are concerned with the items of Korean water quality standard and the priolity pollutnats recommended by WHO. In the results, 45 items of water quality, and the priolity pollutants were not exceeded to the standard and criteria, while DDT, heptachlor-epoxide, THMs, benzo(a)pyrene, Ba, Al, Gross beta, $^{226}$Ra, $^{90}$Sr were detected, the levels were not exceeded to the WHO guidelines. In ordes to evalute the safety of drinking water quality, besides of the existed items of standard, new hazardouse pollutants should be considered monitored continenously. For the regulation of hazardous pollutants, it may be introduced from the risk assessment. According to the relevant assessment, the acceptable risk of pollutants estimated could be applied to set the water quality standard or recommendations or quidelines as well as the number of monitoring.

  • PDF

다리에 힘이 없는 환자에서 효과적인 운동 유발전위 파형 측정에 대한 고찰 (Effective Motor Evoked Potential Waveforms in Patients with Lower Extremity Weakness)

  • 임성혁;박상구;한형태
    • 대한임상검사과학회지
    • /
    • 제48권1호
    • /
    • pp.41-48
    • /
    • 2016
  • Motor evoked potential of spinal surgery is known to cause damage due to the movement path of the continuous scan operation and surgery can be performed with minimized disability after surgery. However, if it is not at all formed at the wave motion evoked potential can occur during surgery and, in some cases the size of the waveform to be measured is very small and intermittent. In this case, the surgery cannot provide information about whether there is neurological damage. Increased intensity of the wave-induced motion of the dislocation does not occur if it appears in a very small amplitude stimulus, but changing the inspection area that electrical stimulation of the waveform changes could not be found. However, stimulation of a wide area in the cerebral cortex was found to occur with a waveform in the patients who underwent examination. Through this study, we propose a useful motor evoked potential test. From November to December 2015 three spine surgery patients visited Samsung Medical Center as neurosurgery patients with omission discomfort, gait disturbance, and no symptom of strength before surgery. In spine surgery patients with motor grade weakness, when motor evoked potential waveform has not been measured, in examination of the site of electrical stimulation of the cerebral cortex from entering the C3+C5/C4+C6 or C3+C1/C4+C2 if by the activity of more motor neuron unit, it was found that the waveform is better formed.

Study on the Short Term Exposure Level (STEL) of the Benzene for the Tank Lorry Truck Drivers during Loading Process

  • Park Doo Yong
    • International Journal of Safety
    • /
    • 제3권1호
    • /
    • pp.27-31
    • /
    • 2004
  • Some of the petroleum products contain benzene which is well known as a confirmed human carcinogen. For example, gasoline products contain benzene ranging up to several percents by weight. High exposures to the benzene and other organic solvents would be likely to occur during intermittent tasks and or processes rather than continuous jobs such as sampling, repair, inspection, and loading/unloading jobs. The work time for these jobs is various. However, most of work time is very short and the representative time interval is 15 minutes. Thus, it is preferable to do exposure assessment for 15 minute time weighted average which is known as a short time exposure level(STEL) by ACGIH rather than for 8-hours TWA. It is particularly significant to the exposure monitoring for benzene since it has been known that the exposure rate plays an important role to provoke the leukemia. Due to the large variations, a number of processes/tasks, the traditional sampling technique for organic solvents with the use of the charcoal and sampling pumps is not appropriate. Limited number of samples can be obtained due to the shortage of sampling pumps. Passive samplers can eliminate these limitations. However, low sampling rates resulted in collection of small amount of the target analysts in the passive samplers. This is originated the nature of passive samplers. Field applications were made with use of passive samplers to compare with the charcoal tube methods for 15 minutes. Gasoline loading processes to the tank lorry trucks at the loading stations in the petroleum products storage area. Good agreements between the results of passive samplers and those of the charcoal tubes were achieved. However, it was found that special cautions were necessary during the analysis at very low concentration levels.

Bilateral Patellar Groove Replacement in a Dog with Iatrogenic Trochlear Groove Damage

  • Kim, Yongrak;Park, Yunsik;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
    • 한국임상수의학회지
    • /
    • 제33권5호
    • /
    • pp.295-299
    • /
    • 2016
  • A 2-year-old, 1.94 kg spayed female Toy Poodle was referred for revision surgery for patellar reluxation following surgery for bilateral medial patellar luxation (MPL). Intermittent non-weight-bearing lameness of the right hindlimb and weight-bearing lameness of the left hindlimb were evident on general inspection. A physical examination revealed that there was a bilateral grade 4 MPL. On radiographs, the medial and lateral trochlear ridge was bilaterally worn out. Patellar groove replacement (PGR) was performed in two stages to replace the bilateral femoral trochlea that had a severely worn out groove. Corrective femoral osteotomy with increasing anteversion angle, tibial tuberosity transposition, medial releasing, lateral imbrications and PGR were performed on the right hindlimb. Six months after surgery on the right hindlimb, a PGR prosthesis was positioned medially on the frontal plane and tibial tuberosity transposition and lateral imbrications were performed on the left hindlimb. Two weeks after surgery, reluxation of the patella occurred on the left hindlimb. The tibial tuberosity transposition was performed to realign the patella more laterally than the previous surgery, and a patellar sling was applied. Two years after the last surgery, the patient showed no pain on the stifle joint and satisfactory weight-bearing ambulation. Reluxation did not recur. PGR maybe a successful treatment for dogs with iatrogenically damaged and/or worn out patellar grooves.

활차구 성형술이 실패한 개에서 관절경을 이용한 진단과 치료 (Arthroscopy for the Diagnosis and Treatment of Failed Trochleoplasty in a Dog)

  • 황준호;허수영;김범석;이상훈;정성목;이해범
    • 한국임상수의학회지
    • /
    • 제32권3호
    • /
    • pp.251-254
    • /
    • 2015
  • 3살 중성화된 수컷 스피츠 (8.4 kg)가 후지 파행으로 본원에 의뢰되었다. 환자는 6주전 양측 내측 슬개골 탈구 교정술을 받았다. 육안상 양측 뒷다리의 간헐적인 파행을 보였으며 신체검사에서 슬관절의 굴신전시 염발음을 동반한 중등도의 통증을 보였다. 방사선 검사상 양측 슬관절에서 연골편의 원위부 이탈과 함께 관절부종이 관찰되었다. 신체검사와 방사선검사를 토대로 양측 슬관절 골연골편의 분리와 이탈이 의심되었다. 관절경을 통해 이탈한 골연골편(우측 $1.5cm{\times}0.9cm{\times}0.2cm$, 좌측 $1.3cm{\times}0.9cm{\times}0.1cm$)을 확인하고 제거하였다. 골연골편을 제거한 후, 슬개골의 비정상적 움직임을 예방하기 위해 관절경을 통해 burr를 이용하여 층진 활차구를 성형해주었다. 환자는 수술 2주후 정상적인 보행을 하였으며 합병증을 보이지 않았다. 관절경은 개의 관절질환 진단 및 치료를 위한 효과적인 수단이다. 이를 통해 관절내 구조물을 확대해서 관찰 할 수 있고 정확한 진단을 할 수 있다. 게다가 관절경을 통한 수술은 일반적인 술부에서 나타날 수 있는 술 후 합병증을 줄여 줄 수 있다.