• Title/Summary/Keyword: interface treatment

Search Result 904, Processing Time 0.025 seconds

A Study on the Surface Wettability of Inorganic Insulator (무기절연물 표면상의 젖음성 변화에 관한 연구)

  • Hwang, Yeong-Han;Eom, Moo-Soo;Lee, Kyu-Chul;Lee, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1233-1235
    • /
    • 1993
  • With the Contact angle of phase epoxy resin on the inorganic filler(glass plate) surface treated with air plasma, we have studied about the interface between epoxy resin and glass plate as simple model of a glass fiber reinforced composite materials. The contact angle on the inorganic filler surface varied with ambient temperature and surface treatment conditions.

  • PDF

The Prospect of Membrane Distillation (Membrane Distillation의 전망)

  • 조한욱;신우철
    • Membrane Journal
    • /
    • v.7 no.2
    • /
    • pp.57-64
    • /
    • 1997
  • Membrane Distillation(MD) is reviewed as an application to new separation technology. Hydrophobic membrane which has been used to microfiltration is feasible material for MD process. MD has perfect selectivity under moderate temperature and is promised to simplify typical water treatment process. The principle of MD separation is phase transition by vapor-liquid interface at the pore of membrane surface. Feed and permeate temperature, composition, membrane wetting, heat and mass transfer phenomena affect the selectivity and flux of MD.

  • PDF

Noble Metal Nanowire Based SERS Sensor

  • Gang, Tae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.87-87
    • /
    • 2013
  • The interface between nanomaterials and biosystems is emerging as one of the broadest and most dynamic areas of science and technology, bringing together biology, chemistry, physics and many areas of engineering, biomedicine. The combination of these diverse areas of research promised to yield revolutionary advances in healthcare, medicine, and life science. For example, the creation of new and powerful nanosensors that enable direct, sensitive, and rapid analysis of biological and chemical species can advance the diagnosis and treatment of disease, discovery and screening of new drug molecules. Nanowire based sensors are emerging as a powerful and general platform for ultrasensitive and multiplex detection of biological and chemical species. Here, we present the studies about noble metal nanowire sensors that can be used for sensitive detection of a wide-range of biological and chemical species including nucleic acids, proteins, and toxic metal ions. Moreover, the optical and electrochemical applications of noble metal nanowires are introduced. Noble metal nanowires are successfully used as plasmonic antennas and nanoelectrodes, thereby provide a pathway for a single molecule sensor, in vivo neural recording, and molecular injection and detection in a single living cell.

  • PDF

Determination of the Failure Paths of Leadframe/EMC Joints

  • Lee, H.Y.;Kim, S.R.
    • Journal of Surface Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.241-250
    • /
    • 2000
  • Popcorn cracking phenomena frequently occur in thin plastic packages during the solder reflow process, which are definitely affected by poor adhesion of Cu-based leadframe to epoxy molding compounds (EMCs). In the present work, in order to enhance the adhesion strength, a brown-oxide treatment on the Cu-based leadframe was carried out and the adhesion strength of leadframe/EMC interface was measured in terms of fracture toughness by using sandwiched double-cantilever beam (SDCB) specimens. After the adhesion tests, fracture surfaces were analyzed by SEM, AES, EDS and AFM to make the failure path clear. Results showed that failure path was closely related to the oxidation time and the interfacial fracture toughness.

  • PDF

EFFECT OF SUBSTRATE BIAS ON THE DIAMOND GROWTH USING MICROWAVE PLASMA CVD

  • Sakamoto, Yukihiro;Takaya, Matsufumi
    • Journal of Surface Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.303-306
    • /
    • 1999
  • On the effect of substrate bias at first stage of diamond synthesis at lower substrate temperature(approximately 673K) using microwave plasma CVD and effect of reaction gas system for the bias enhanced nucleation were studied. The reaction gas was mixture of methane and hydrogen or carbon monoxide and hydrogen. The nucleation density of applied bias -150V using $CH_4-H_2$ reaction gas system, significantly higher than that of $C-H_2$ reaction gas system. When the $CH_4-H_2$ reaction was used, nucleation density was increased because of existence of SiC as a interface for diamond nucleation. By use of this negative bias effect for fabrication of CVD diamond film using two-step diamond growth without pre-treatment, fabrication of the diamond film consist of diamond grains $0.2\mu\textrm{m}$ in diameter was demonstrated

  • PDF

Surface Characteristics of Anodized Ti-30Nb-xTa Alloys with Ta Content

  • Kim, Eun-Sil;Ko, Yeong-Mu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.254-254
    • /
    • 2012
  • The purposed of this work was to determine surface charateristics of anodized Ti-30Nb-xTa alloys with Ta content. Samples were prepared by arc melting, followed by followed by homogenization for 12 hr at $1000^{\circ}C$ in argon atmosphere. The electrolyte for anodization treatment was prepared by mixing 465ml $H_2O$ with 35M $H_3PO_4$ and anodized at 180V to 220V. The microstructures of the alloys were examined by X-ray diffractometer (XRD) and optical microscopy (OM). Surface characteristics of anodized Ti-30Nb-xTa alloys was investigated by potentiodynamic test and potentiostatic in 0.9% Nacl solution at $36.5{\pm}1^{\circ}C$. It was observed that the changed ${\alpha}$ phase to ${\beta}$ phase with Ta content.

  • PDF

Ultrathin Polymer Networks of Itaconic Acid Copolymers and Poly(allkylamine) by the ;angmuir-Blodgett Technique

  • 최기선;이범종;장상목;권영수
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.6
    • /
    • pp.493-498
    • /
    • 1995
  • Ultrathin networks of itaconic acid copolymers and poly(allylamine) were produced by a Langmuir-Blodgett (LB) technique employing a double-chain amine as a monolayer template which was subsequently removed by extraction after thermal crosslinking. Itaconic acid copolymers used were copoly (itaconic acid-ethyl vinyl ether) and copoly (itaconic acid-n-butyl vinyl ether). The polyion-complexed monolayers of three components consisting of template amine, itaconic acid copolymer and poly (allylamine) were formed at the air-water interface. The Langmuir film properties have been studied by the surface pressure-area isotherm and fluorescence microscopy. The monolayers were transferred on solid substrates and were characterized by FT-IR spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy (SEM). Two-dimensional polymer networks were formed through imide or amide linkages by heat treatment under vacuum. The heat-treated films were extracted with chloroform after immersion in aq. sodium chloride to remove the template amines. SEM observation of a LB film on a porous fluorocarbon membrane filter with pore diameter of 0.1 μm showed covering of the pores by six layers in the polyion complex state.

Magnetoresistance Characteristics due to the Schottky Contact of Zinc Tin Oixide Thin Films (ZTO 박막의 쇼키접합에 기인하는 자기저항특성)

  • Li, XiangJiang;Oh, Teresa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.120-123
    • /
    • 2019
  • The effect of surface plasmon on ZTO thin films was investigated. The phenomenon of depletion occurring in the interface of the ZTO thin film created a potential barrier and the dielectric layer of the depletion formed a non-mass particle called plasmon. ZTO thin film represents n-type semiconductor features, and surface current by plasma has been able to obtain the effect of improving electrical efficiency as a result of high current at positive voltage and low current at negative voltage. It can be seen that the reduction of electric charge due to recombination of electronic hole pairs by heat treatment of compound semiconductors induces higher surface current in semiconductor devices.

Improved Dit between ALD HfAlO Dielectric and InGaAs Substrate Using NH3 Plasma Passivation (InGaAs 위의 NH3 Plasma Passivation을 이용한 ALD HfAlO유전체 계면전하(Dit) 향상)

  • Choi, Jae Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • The effect of $NH_3$ plasma passivation on the chemical and electrical characteristics of ALD HfAlO dielectric on the InGaAs substrate was investigated. The results show that $NH_3$ plasma passivation exhibit better electrical & chemical performance such as much lower leakage current, lower density of interface trap(Dit) level, and low unstable interfacial oxide. $NH_3$ plasma passivation can effectively enhance interfacial characteristics. Therefore $NH_3$ plasma passivation improved the HfAlO dielectric performance on the InGaAs substrate.

Electric Therapy System Based on Discontinuous Conduction Mode Boost Circuit

  • Chen, Wenhui;Lee, Hyesoo;Jung, Heokyung
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.4
    • /
    • pp.245-253
    • /
    • 2020
  • The human body and nervous system transmit information through electric charges. After the electric charge transmits information to the brain, we can feel pain, numbness, comfort, and other feelings. Electric therapy is currently used widely in clinical practice because the field of examination is more representative of electrocardiogram, and in the field of treatment is more representative of electrotherapy. In this study, we design a system for neurophysiological therapy and conduct parameter calculation and model selection for the components of the system. The system is based on a discontinuous conduction mode (DCM) boost circuit, and controlled and regulated by a single-chip microcomputer. The system does not only have a low cost but also fully considers the safety of use, convenience of the human-computer interface, adjustment sensitivity, and waveform diversity in the design. In future, it will have strong implications in the field of electrotherapy.