• Title/Summary/Keyword: interest region

Search Result 1,518, Processing Time 0.032 seconds

Developmnet of Vibration and Impact Noise Damping Wood-based Composites (II) -The Influence of the Degree of Crosslinking on the Damping Properties of Interpenetrating Polymer Networks- (진동.충격음 흡수성능을 지니는 목질계 복합재료의 개발(II) -가교밀도가 상호침투망목고분자의 진동흡수성능에 미치는 영향-)

  • 이현종
    • Journal of Korea Foresty Energy
    • /
    • v.17 no.1
    • /
    • pp.47-55
    • /
    • 1998
  • In the search for broadband damping composites, it is desirable to have polymers with a broad and high loss region, covering the entire temperature and frequency range of interest. Interpenetrating polymer networks, IPN's, are materials composed of two or more crosslinked polymers intimately and irrevocably interwinded. The resulting distribution of microenviron-ments can result in a materials with a high mechanical loss broad end over that of either polymer component alone. In this study, several series of copolymer, crosslinked copolymer and copolymer/copolymer IPN's were synthesized for possible use as broadband damping materials. Then their dynamic tensile properties were measured and compared with the damping properties of sandwich composites. Dynamic mechanical analysis showed that the temperature of loss peak may be varied over a wide temperature range with formulation. The compatibility of IPN`s was depended on the compatibility of A and B polymers as well as crosslink density. The damping factor(tan ${\delta}_c$) of composites became greater when a polymer of approximate storage module(E`) range of 5X10$^7$ to 10$^9$ dyne/cm$^2$ and large tan ${\delta}$ at the same time was used. The damping properities of poly (2-EHA80-co-St20)/poly(2-EHA20-co-St80) IPN`s crosslinked with 3%-DEGDM were relatively better over a broad temperature range.

  • PDF

The Effect of Metallic Dental Implant on Positron Emission Tomography Computed Tomography Image (금속성 치아충전물이 PET/CT영상이 미치는 영향)

  • Kim, Ki-Jin;Bae, Seok-Hwan;Han, Sang-Hyun;Yu, Se-Jong;Lee, Bo-Woo
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.243-247
    • /
    • 2012
  • Beam hardening artifact happens in the CT image. when a PET/CT is conducted while there is a metallic dental implant. The artifact appears in the CT image can affect the PET image. When the patient with head and neck cancer has a metallic dental implant, Beam hardening artifact which was taken in th CT image can change the PET image and SUV value. Therefore, by Quantitative measure of the SUV according to the change in HU by the metallic dental implant, the appropriacy in the clinical application was assessed. The records of 47 patients with PET/CT August 2011. For the analysis, 2 region of interest were defined in area where CT and PET image. As a result of the experiment, if there in an implant, the HU and the SUV increased and there existed a statistically significant difference(p<0.01). Although this level of increase was not large compared with that in the patient who have no metallic dental implant, when a person has head and neck cancer, it is even more likely to be overestimated when diagnosing the cancer. When conducting PET/CT for the patient who have head and neck cancer, the physical biological parts should be considered in order not to make an error in decoding.

The Suggestion for Classification of Biotope Type for Nationwide Application (전국적 적용을 위한 비오톱유형분류 제안)

  • Choi, Il-Ki;Oh, Choong-Hyeon;Lee, Eun-Heui
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.6
    • /
    • pp.666-678
    • /
    • 2008
  • The needs for drawing up of biotope map is rapidly spreaded over each local government recently in Korea, according as enhancing of interest about biotope, which is recognized to practical instrument for concretely being able to considering natural environment and ecosystem on all sorts of development plan. However, there are not yet the standard suggestion on biotope types and classification systems and biotope classification criteria. Therefore, each other methodologies are applied to each of local autonomies. First, under such critical mind the biotope types and classification systems were drafted by a review on biotope types, biotope classification systems, and biotope classification criteria of the preceded case studies until now at the inside and outside of the country. And then the purpose of this study is to derive biotope types and biotope classification systems applicable to the whole Korean region through continual feed back such as field surveys in selected representative areas and consultations. As a result of reviewing the case examples, first, the biotope classification systems were mixed two steps system with three steps system and those were composed mostly of the structure of two steps: large and small. Second, land-use, soil pavement ratio, green cover ratio, and vegetation usually were applied to the biotope classification criteria. This study suggests that the biotope classification system is consisted of four steps system: large(biotope class), medium(biotope group), small(biotope type) and detail(sub-biotope type), and the biotope types are classified into 13 types of large step, 45 types of medium step and 127 types of small step. However, this study suggests that the new biotope types on small step or detail step should be continually supplemented with the foundation of classification system proposed in this study because the biotope type classification should consider regional characteristics.

Fabrication and Evaluation of High Frequency Ultrasound Receive Transducers for Intravascular Photoacoustic Imaging (혈관내 광음향 영상을 위한 고주파수 초음파 수신 변환기 제작 및 평가)

  • Lee, Jun-Su;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.300-308
    • /
    • 2014
  • Photoacoustic imaging is a useful tool for the diagnosis of atherosclerosis because it is capable of providing anatomical and pathological information at the same time. A photoacoustic signal detector is a pivotal element to achieve high spatial resolution, so that it should have broadband spectrum with a high center frequency. Since a photoacoustic imaging probe is directly inserted into blood vessel to diagnose atherosclerosis, the total size of the photoacoustic signal detector should be less than 1 mm. The main purpose of this paper is to demonstrate that PVDF can be used as an active material for the photoacoustic signal detector with a high frequency and broadband characteristic. The photoacoustic signal detector developed in this study was a single element ultrasound transducer with an aperture of $0.5{\times}0.5mm$ and the total size of 1 mm. In the design stage, the natural focal depth was adjusted for an effective focal area to cover the region of interest, i.e., 1~5 mm in depth. This was because geometrical focusing could not be used due to the small aperture. Through a pulse-echo test, it was ascertained that the developed photoacoustic signal detector has the -6 dB bandwidth ranging between 40.1 and 112.8 MHz and the center frequency of 76.83 MHz.

Change master cast by hardening method to position of tray after impression taking (인상채득 후 경화시 트레이의 위치에 따른 주모형의 변화)

  • Lee, Jung Ae
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.53-66
    • /
    • 2008
  • There was to purpose of this study improves analyzing cause that prosthesis brings bite engaging that is inaccurate in patient's mouth, when supposed that all conducts that do in operatory and dental laboratory are perfect. Impression did check bite by alginate impression material and polymerization style silicon impression material that use usually in presence at a sickbed Irreversibility, hydrocolloid, alginate impression material washed in flowing water and poured anhydrite after wait about 8 minutes so that region that charge interest after impression check bite may become undoing. And hydrophile property addition polymerization style impression material poured anhydrite after blow 30 considering impression material dwell time and H2 gas occurrence time (5~15 minute) after have washed in flowing water. I got each 7 models, result that manufactures total 28 and measures by third dimension measuring instrument (Meteo, Korea) following sequence curing in tray holder and floor 1, By Alginate impression when is hardened in tray holder and when is hardened in the floor after do check bite, SPH 4, SPH5 all as there is synonymy appeared(P<0.05). By in case do not use average 0.1741 in case use tray holder in 0.0447 SPH5s in case do not use average 0.2838 pastas in case use tray holder in SPH4 0.0309, When did not use both SPH4 and SPH5 tray holder, when used tray holder, 1 appeared more greatly. 2. By amity sex addition polymerization style silicon impression when is hardened in tray holder after do check bite and when is hardened in the floor SPH 4, a11 of the SPH5s very big synonymy be(P>0.05). And in case use tray holder in 0.000657 pasta SPH5s in case do not use average 0.000129 pastas in case use tray holder in SPH4 average 0.000114 pastas, by in case do not use 0.000757, I appeared more greatly when used tray when did not use both SPH4 and SPH5 tray holder, but 1 appeared is not level to keep in mind(Table 8~9). 3 SPH4 was looked very big mindfulness in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon without using tray holder(P< 0.001). I use tray holder and SPH4 did not appear synonymy in model that manufacture doing impression check bite by Alginate and model that do impression check bite by amity sex accessory penalty silicon(P>0.05). Study finding of above when see synthesis Alginate certainly tray holder use must and I could know that hardening method does not exert big influence on volume stability if remove impression sieve of excess because amity sex accessory penalty silicon passes over tray, Also, Alginate impression material previewed can get heading a conspiracy style that volume stability of accessory penalty silicon impression material degree is if use tray holder.

  • PDF

Sea Cucumber (Stichopus japonicus) Grading System Based on Morphological Features during Rehydration Process (수화 시의 형태학적 특징에 따른 건해삼의 등급 분류 시스템 개발)

  • Lee, Choong Uk;Yoon, Won Byong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.3
    • /
    • pp.374-380
    • /
    • 2017
  • Image analysis and k-mean clustering were conducted to develop a grading system of dried sea cucumber (SC) based on rehydration rate. The SC images were obtained by taking pictures in a box under controlled light conditions. The region of interest was extracted to depict the shape of the SC in a 2D graph, and those 2D shapes were rendered to build a 3D model. The results from the image analysis provided the morphological features of the SC, including length, width, surface area, and volume, to obtain the parameters of the k-mean clustering weight. The k-mean clustering classified the SC samples into three different grades. Each SC sample was rehydrated at $30^{\circ}C$ for 40 h. During rehydration, the flux of each grade was analyzed. Our study demonstrates that the mass transfer rate of SC increased as the surface area increased, and the grade of SC was classified based on rehydration rate. This study suggests that the optimal rehydration process for SC can be achieved by applying a suitable grading system.

Bone changes around the maxillary posterior teeth opposing the implants in mandible: a clinical study (하악 임플란트에 대합되는 상악 구치의 주변골 변화에 대한 임상연구)

  • Park, Chan-Jin;Huh, Yoon-Hyuk;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: When the edentulous area is restored by implant prostheses, the opposing hypofunctioned teeth will receive physiologic mechanical stimuli. This study evaluated the bone changes around the maxillary teeth opposing an implant restoration installed in the mandibular posterior area. Materials and Methods: Radiographs of the opposing teeth were taken at prostheses delivery (baseline), 3 and 6 months later. A customized film holding device was fabricated to standardize the projection geometry for the serial radiographs of the opposing teeth. The gray values of the region of interest of each digital image were compared according to time. Repeated measured analysis of variance was performed at the 95% significance level. Results: The gray values of the alveolar bone around the antagonist teeth of implants increased with time. The changes in gray values of the middle area were greater than those of the crestal area. However, the gray values of the mesial and distal areas were not different. The changes in gray values were different according to the unloaded time. Conclusion: A change in bone tissue will occur if a proper physiologic load is again applied to the bone tissues around a hypofunctioned tooth.

Analyzing Growth Factors of Alley Markets Using Time-Series Clustering and Logistic Regression (시계열 군집분석과 로지스틱 회귀분석을 이용한 골목상권 성장요인 연구)

  • Kang, Hyun Mo;Lee, Sang-Kyeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.535-543
    • /
    • 2019
  • Recently, growing social interest in alley markets, which have shown rapid growth like Gyeonglidan-gil street in Seoul, has led to the need for an analysis of growth factors. This paper aims at exploring growing alley markets through time-series clustering using DTW (Dynamic Time Warping) and examining the growth factors through logistic regression. According to cluster analysis, the number of growing markets of the Northeast, the Southwest, and the Southeast were much more than the Northwest but the proportion in region of the Northwest, the Northeast, and the Southwest were much more than the Southeast. Logistic regression results show that people in 20s and 30s have a lower impact on sales than those in 50s, but have a greater impact on growth of alley market. Alley markets located in high-income areas often reached their growth limits, indicating a tendency to stagnate or decline. The proximity of a subway station effected positive on sales but negative on growth. This research is an advanced study in that the causes of sales growth of alley markets is examined, which has not been examined in the preceding study.

Fine Co-registration Performance of KOMPSAT-3·3A Imagery According to Convergence Angles (수렴각에 따른 KOMPSAT-3·3A호 영상 간 정밀 상호좌표등록 결과 분석)

  • Han, Youkyung;Kim, Taeheon;Kim, Yeji;Lee, Jeongho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.491-498
    • /
    • 2019
  • This study analyzed how the accuracy of co-registration varies depending on the convergence angles between two KOMPSAT-3·3A images. Most very-high-resolution satellite images provide initial coordinate information through metadata. Since the search area for performing image co-registration can be reduced by using the initial coordinate information, in this study, the mutual information method showing high matching reliability in the small search area is used. Initial coarse co-registration was performed by using multi-spectral images with relatively low resolution, and precise fine co-registration was conducted centering on the region of interest of the panchromatic image for more accurate co-registration performance. The experiment was conducted by 120 combination of 16 KOMPSAT-3·3A 1G images taken in Daejeon area. Experimental results show that a correlation coefficient between the convergence angles and fine co-registration errors was 0.59. In particular, we have shown the larger the convergence angle, the lower the accuracy of co-registration performance.

Characteristics of amorphous IZTO-based transparent thin film transistors (비정질 IZTO기반의 투명 박막 트렌지스터 특성)

  • Shin, Han-Jae;Lee, Keun-Young;Han, Dong-Cheul;Lee, Do-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.151-151
    • /
    • 2009
  • Recently, there has been increasing interest in amorphous oxide semiconductors to find alternative materials for an amorphous silicon or organic semiconductor layer as a channel in thin film transistors(TFTs) for transparent electronic devices owing to their high mobility and low photo-sensitivity. The fabriction of amorphous oxide-based TFTs at room temperature on plastic substrates is a key technology to realize transparent flexible electronics. Amorphous oxides allows for controllable conductivity, which permits it to be used both as a transparent semiconductor or conductor, and so to be used both as active and source/drain layers in TFTs. One of the materials that is being responsible for this revolution in the electronics is indium-zinc-tin oxide(IZTO). Since this is relatively new material, it is important to study the properties of room-temperature deposited IZTO thin films and exploration in a possible integration of the material in flexible TFT devices. In this research, we deposited IZTO thin films on polyethylene naphthalate substrate at room temperature by using magnetron sputtering system and investigated their properties. Furthermore, we revealed the fabrication and characteristics of top-gate-type transparent TFTs with IZTO layers, seen in Fig. 1. The experimental results show that by varying the oxygen flow rate during deposition, it can be prepared the IZTO thin films of two-types; One a conductive film that exhibits a resistivity of $2\times10^{-4}$ ohm${\cdot}$cm; the other, semiconductor film with a resistivity of 9 ohm${\cdot}$cm. The TFT devices with IZTO layers are optically transparent in visible region and operate in enhancement mode. The threshold voltage, field effect mobility, on-off current ratio, and sub-threshold slope of the TFT are -0.5 V, $7.2\;cm^2/Vs$, $\sim10^7$ and 0.2 V/decade, respectively. These results will contribute to applications of select TFT to transparent flexible electronics.

  • PDF