• 제목/요약/키워드: interception facility

검색결과 12건 처리시간 0.02초

생태저류지 LID 시설의 강우유출수 처리비 산정 (Estimation of Stormwater Interception Rate for Bio-retention LID Facility)

  • 최정현;이옥정;김상단
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.563-571
    • /
    • 2017
  • Because of the rapid progress of urbanization in recent decades, the proportion of impervious areas in cities has increased. As a result, hydrological properties of urban streams have changed and non-point pollution sources have increased, that have had considerable influence on human life and ecosystems. To manage these situations, application of non-point pollution reduction facilities and LID facilities are expanding recently. In this study, it is investigated if rainfall interception rate used in design of non-point pollution reduction facilities can be applied to design of LID facilities. For this purpose, EPA SWMM is constructed for part of Noksan National Industrial Complex area wherein long-term observed storm water data can be obtained and storm water interception rates for various design capacities of a bio-retention LID facility reservoirs are estimated. While sensitivity of storm water interception rate according to design specifications of bio-retention facility is not large, sensitivity of storm water interception rate according to regional rainfall characteristics is relatively large. As a result of comparing present rainfall interception rate estimation method with the one proposed in this study, the present method is highly likely to overestimate performance of the bio-retention facility. Finally, a new storm water interception rate formula for bio-retention LID facility is proposed.

Estimation of stormwater interception ratio for evaluating LID facilities performance in Korea

  • Choi, Jeonghyeon;Lee, Okjeong;Lee, Jeonghoon;Kim, Sangdan
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.19-28
    • /
    • 2019
  • To minimize the impact of urbanization, accurate performance evaluation of Low Impact Development (LID) facilities is needed. In Korea, the method designed to evaluate large-scale non-point pollution reduction facilities is being applied to LID facilities. However, it has been pointed out that this method is not suitable for evaluating the performance of relatively small-scale installed LID facilities. In this study, a new design formula was proposed based on the ratio of LID facility area and contributing drainage area, for estimating the Stormwater Interception Ratio (SIR) for LID facilities. The SIR was estimated for bio-retentions, infiltration trenches and vegetative swales, which are typical LID facilities, under various conditions through long-term stormwater simulation using the LID module of EPA SWMM. Based on the results of these numerical experiments, the new SIR formula for each LID facility was derived. The sensitivity of the proposed SIR formula to local rainfall properties and design variables is analysed. In addition, the SIR formula was compared with the existing design formula, the Rainfall Interception Ratio (RIR).

유해 전자파의 인체적 영향과 유.무기 복합 전도성 코팅제에 의한 전자파 차단 특성에 관한 연구 (Related to research some pollutants electromagnetic wave's impact of the human body and electromagnetic wave's a specific interception by the conductibility coating with organic.inorganic composition matter)

  • 유희옥;윤정필;강병복;임중열;차인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.254-257
    • /
    • 2001
  • This paper is managing about problem and EMI by electromagnetic waves occurrence of electrical appliances and harmfulness of EMS and standard. Specially, because this paper certifies a mouse and electromagnetic waves interception effect of electricity market place which possess electromagnetic waves interception facility, there is effect that contribute in health life that do to secure safe going to sleep condition from electromagnetic waves of electricity market place that is security of computer working environment of safe state through electromagnetic waves interception and essential electric appliance of home life.

  • PDF

도로 빗물받이 유입구의 차집유량 산정식 (Intercepted flow equation at grate inlet on road)

  • 김정수;곽상호;류택희;윤세의
    • 한국수자원학회논문집
    • /
    • 제49권6호
    • /
    • pp.537-549
    • /
    • 2016
  • 일반적으로 쇠살대 빗물받이는 도로 표면유출 흐름을 차집하여 도시배수 시설로 배제하기 위하여 설치된다. 빗물받이의 규모 및 설치간격을 결정하기 위하여 빗물받이 차집유량 산정식이 필요하다. 그러므로 쇠살대 빗물받이 유입구의 차집능력 분석이 필요하다. 본 연구에서는 도로 빗물받이의 차집유량 산정을 위해 수리실험모형을 제작하여 720회의 실험을 실시하였다. 빗물받이 제원은 현재 대부분의 국도에 설치되는 크기인 $40{\times}50cm$, $40{\times}100cm$$40{\times}150cm$를 Froude 상사법칙을 이용하여 1/2로 축소 모형을 제작하였다. 측구의 유량은 도로의 차선(2~4차선), 경사(도로 종경사 2~10 %, 측구 횡경사 2~10 %) 및 설계빈도(최대 30년)을 고려하였다. 실험 결과 측구의 횡경사가 커질수록 빗물받이로 유입되는 유량은 증가하였으며, 빗물받이 유입부의 길이가 증가함에 따라 유입부 측면부를 통한 횡유입량을 증가시켜 빗물받이 유입부의 차집효율을 증가시켰다. 실측 차집유량을 이용하여 회귀분석 실시하여 빗물받이 유입구 크기별 차집유입량 산정식을 도출하였다. 기존 경험식과 비교한 결과, 도출된 산정식은 상향된 빈도를 반영한 빗물받이 유입부의 차집유량을 보다 정확하게 산정하였으며, 도로 배수시설 설계에 기초자료로 활용이 가능할 것으로 판단된다.

생태저류지 LID 시설의 설계 및 평가를 위한 삭감대상부하비 산정방법 개선 (mprovement of Estimation Method of Load Capture Ratio for Design and Evaluation of Bio-retention LID Facility)

  • 최정현;이옥정;김용석;김상단
    • 한국물환경학회지
    • /
    • 제34권6호
    • /
    • pp.569-578
    • /
    • 2018
  • To minimize the negative alterations in hydrologic and water quality environment in urban areas due to urbanization, Low Impact Development (LID) techniques are actively applied. In Korea, LID facilities are classified as Non-point Pollution Reduction Facilities (NPRFs), and therefore they are evaluated using the performance evaluation method for NPRFs. However, while LID facilities are generally installed in small, distributed configuration and mainly work with the infiltration process, the existing NPRFs are installed on a large scale and mainly work with the reservoir process. Therefore, some limitations are expected in assessing both facilities using the same method as they differ in properties. To solve these problems, in this study, a new method for performance evaluation was proposed with focus on bio-retention LID facilities. EPA SWMM was used to reproduce the hydrologic and water quality phenomena in study area, and SWMM-LID module used to simulate TP interception performance by installing a bio-retention cell under various conditions through long-term simulations. Finally, an empirical formula for Load Capture Ratio (LCR) was derived based on storm water interception ratio in the same form as the existing method. Using the existing formula in estimating the LCR is likely to overestimate the performance of interception for non-point pollutants in the extremely low design capacity, and also underestimate it in the moderate and high design capacity.

A STUDY ON THE LIFE-CYCLE FOR SELECTING A GRATING

  • Yun-Sik Kim;Dong-Wan Kang;Taehoon Hong;Chang-Taek Hyun
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1189-1194
    • /
    • 2009
  • A gutter-shaped U grating is a facility that is installed at the sides of a road to provide pedestrians with a rainwater-free road. The previous studies on this facility focused mainly on the progress of the efforts that are being made to improve its performance and interception efficiency so as to prevent damages in regional areas due to the heavy rains caused by climate change. The studies on its maintenance, however, are still inadequate. Therefore, this study was conducted to analyze and compare the life cycle costs and performance evaluations of the steel and magic gratings, which are installed in apartments. The results of the study show that the replacement period and rate of gratings differ depending on where they are installed. The initial capital investment cost of a magic grating installed at a road where many vehicles pass is quite high, but in terms of its maintenance and entire-life-cycle costs, its total expenses are lower than those of a steel grating. The results of this study are expected to serve as preliminary data for the selection of an adequate grating that is suitable for particular places in the design phase of construction projects.

  • PDF

강우조건에 따른 차집시설에서의 비점오염물질 유출특성분석 (Analysis of the Discharge Characteristics of Non-point Pollutants from the Interception Facilities according to Rainfall Conditions)

  • 임자유;은범진;허정숙;최이송;오종민
    • 환경영향평가
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2022
  • 본 연구는 비점오염원 저감시설인 차집시설을 대상으로 다양한 강우조건에 따라 초기우수 유출수의 수질특성을 파악하고, 용존성 오염물질의 기원을 파악하기 위하여 수행되었다. 본 연구는 도시지역 내 위치한 G-배수구역의 10개 차집시설 중 비강우시에도 불명수가 유입되는 것으로 조사된 차집시설 #1, #5, #8, #9 및 #10 등 5개 지점에서 수질분석을 통하여 차집시설에서 비점오염물질의 유출특성을 파악하였다. 연구결과로써 강우량에 따라 차집시설에서 우수유출수의 수질특성에 영향을 받는 것으로 판단되었다. 비강우시 EC, BOD, TOC, TN의 평균농도는 강우시에 비하여 높은 것으로 조사되었으며, DO의 평균농도는 강우시에 비하여 낮은 것으로 조사되었다. 또한, 차집시설에서 유출수의 용존성 유기물은 주로 내부에서 생성된 유기물로 구성된 것으로 판단되었다. 우수유출수는 주변 환경에서 유입되는 오염물질의 영향을 많이 받으며, 강우로 인하여 차집시설의 외부로부터 유입되는 난분해성 휴믹계 물질이 많아진 것으로 판단된다.

오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(II) - 차집용량과 월류오염부하 삭감목표 설정 - (Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed (II) - Establishment of Intercepting Capacity and Reduction Goal of Overflow Pollution Load -)

  • 이두진;신응배
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.557-564
    • /
    • 2005
  • The objective of this study is to evaluate a criteria of intercepting capacity and a reduction goal of overflow pollution load in combined sewer system. In the current criteria of intercepting capacity in the domestic sewage facility standard, it is known that three times of peak sewage (Q) in dry period or runoff flow by 2mm/hr is not appropriate since the intercepted flow is estimated by runoff and show different result even in the same watershed. Though a reduction goal of overflow pollution load can be determined from 1) same level of storm-water runoff pollution load in separated storm sewer, 2) less than 5% sewage load in dry weather period, by the domestic sewage facility standard, the simulated results from storm-water model show large differences between two criteria. While it is predicted that sewage pollution load standard three time larger than separated storm sewer standard in high population density and urbanized area, it is shown that separate storm sewer standard larger than sewage pollution load standard in middle population density and developing area. Accordingly, it is proposed that more reasonable intercepting flow and reduction goal of overflows pollution load should be established to minimize discharging pollution load in combined sewer systems. For the purpose, a resonable standard has to be amended by pollution load balance considering the characteristics of a watershed for generation, collection, treatment, and discharging flow.

노인요양시설 거주노인의 활동공간 이용행동 및 점유행태 (A Study of the Residents' Use and Occupancy-Behavior in the Activity Areas of the Senior Nursing Facilities)

  • 이민아
    • 가정과삶의질연구
    • /
    • 제27권5호
    • /
    • pp.77-90
    • /
    • 2009
  • The purpose of this study was to investigate the residents' use and occupancy-behavior in the activity areas of the senior nursing facilities, and to provide basic information to establish the appropriate physical elements for planning the activity areas. For the study, the observations in five facilities were conducted for one day, from 10 a.m. to 4 p.m by four researchers. The results of the study are summarized as follows: First, most of the using behaviors in the activity areas were the doing nothing or sleeping. The meals and program services were provided in only one activity area of the floor and it showed that the unit care system was perfunctorily conducted at those facilities. In the representative activity area, its openness was the main physical element influencing the spatial using frequency, while the accessibility and the openness in the sub-activity area were most important. The seating arrangements having comers were helpful for residents' interactions. Second, while facility programs and meals were provided in the specific activity area, there was no residents' occupancy in other activity areas at the same time. There were interactions including residents' conversations and watching/observations in non-designated activity areas such as the nursing stations and near corridors. But the residents' interactions and self-regulations were blocked by absence of territoriality, monotonous spatial compositions and furniture arrangements, insecurity of residents' privacy, wide or narrow areas, and isolated spatial type. Based on the results at the above, basic guidelines for planning the activity areas of senior nursing facilities can be proposed as follows: First, the isolated type and the sight interception should be avoided in representative activity areas. It should be partitioned with couple of areas through the appropriate furniture arrangements, and be prepared semi-private spaces in non-designated areas such as nursing station for the interactions among the residents and the staff. Second, in activity areas for small group, the isolated type is not also good for the residents' accessibility. The residents' privacy should be confirmed through the various spatial compositions, and enough areas need to be sure for the diverse furniture arrangements.

농촌지역 소하천의 환경성 평가 연구 - 홍성군 홍동천을 사례로 - (The Study on the Evaluation of Environment Function at Small Stream - In the Case of Hongdong Stream in Hongsung-gun -)

  • 강방훈;손진관
    • 한국환경복원기술학회지
    • /
    • 제14권5호
    • /
    • pp.81-101
    • /
    • 2011
  • This study was conducted to understand the environmental and ecological function of habitat through evaluation of water environment, soil environment, vegetation characteristics, macro-invertebrate characteristics, and visual habits environment evaluation (SVAP) in Hongdong stream located in Hongseong-Gun, Chungnam Province, and hereafter to utilize the results for the habits reconstruction and improvement project. As the results of water quality analysis, BOD, COD, T-P was almost below the standard quality from upper stream to down stream. The construction of small reservoir, wetland and water purification facility, and the management of non-point pollution are proposed to improve these problems. The soil texture was sandy soil, which is unfitted with vegetation development. The construction of shallows and bogs, and induction of soil sedimentation and biotope formation are proposed to improve these problems. In the plant flora, total 90 kinds were observed with 81 species and nine varieties in total 36 families and 85 genera, and the naturalization rate was higher at down area than upper area. As the results of macro-invertebrate fauna survey, total 26 species and 297 individuals in 20 families and 22 genera were collected. Peltodytes sinensis, Chironomidae sp., and Culicidae sp., which are observed at polluted environment, were collected as dominant species. An appropriate vegetation management party idea is necessary, and it is done an idea in consideration of the soil and a physical characteristic. Visual habits environment evaluation (SVAP) result was mostly determined with below normal (Fair) grade. Pollution source interception, purification pond establishment, and various bog establishment are proposed to improve these problems. With the above results, the ecological environment was determined with bad condition, and the improvement of biotope was urgently needed through sustainable monitoring and management of streams habitat in rural area.