• Title/Summary/Keyword: intercepted

Search Result 124, Processing Time 0.026 seconds

Analysis of Padding Oracle Attack Possibility about Application Environment; SRTP, MIKEY, CMS, IPSec, TLS, IPTV (SRTP, MIKEY, CMS, IPSec, TLS, IPTV에 대한 패딩 오라클 공격 가능성 분석)

  • Hwang, Seongjin;Park, Myungseo;Moon, Dukjae;Kang, HyungChul;Kim, Jongsung;Lee, Changhoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • In the various application environments on the internet, we use verified cipher algorithm to protect personal information. Even so, if an application method isn't proper, the information you want to keep can be intercepted. One of the representative examples of it is a PADDING ORACLE ATTACK. This thesis studied about STRP, MIKEY, CMS, IPSec, TLS, IPTV, an application environment which apply CBC operational mode based on block cipher and CBC padding method, and about whether we can attack against the Padding Oracle Attack as well as the vulnerable points.

A Study on the VoIP Security vulnerability over MANET (MANET 기반 VoIP의 보안 취약성 연구)

  • Yoon, Tong-Il;Kim, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.431-433
    • /
    • 2010
  • VoIP is a communication technique can be used anywhere you can find wifi signal and it costs much lower than conventional mobile service. However, security of VoIP is not as robust as former, the converse could be easily intercepted and attacked especially in MANETs which the attackers access easier than in wired networks. Sercurity of VoIP system in MANETs is an important issue nowadays. In this paper, a typical attack method of VoIP systems in MANETs is described and we implement how to prevent it.

  • PDF

Responses of Capsicum annum (red pepper) to Fertilization Rates at Various Soil Moisture Conditions

  • Jung, Kang-Ho;Sonn, Yeon-Kyu;Han, Kyoung-Hwa;Zhang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.332-339
    • /
    • 2014
  • This research was performed to test the hypothesis that the optimal fertilization rate for red pepper is changed by soil moisture condition. The experiment was conducted in rainfall-intercepted fields in Suwon, South Korea from 2002 to 2003. Soil was irrigated at 30, 50, or 80 kPa of soil moisture tension at 20 cm soil depth in 2002 and 30, 50, 100, or 150 kPa in 2003. For both years, fertilization was performed with four levels: none, 0.5, 1, and 1.5 times of the recommended N, P, and K fertilization rate. The irrigation amount was the greatest at 30 kPa irrigation while the water use efficiency increased with decrease of irrigation amount. The Irrigation amount was 508 mm at 30 kPa irrigation and ranged from 355 mm to 435 mm at 50 kPa irrigation. The maximum yield was found at 30 kPa irrigation and 1.5 times of the recommend fertilization rate in 2002 and 2003. The yield index of red pepper increased linearly with the fertilization rate at 30 kPa which implied that excess irrigation induced nutrient leaching and reduced nutrient availability. The maximum yield in 50 kPa and 80 kPa was found at the recommend fertilization rate while the yield decreased by fertilization at 100 kPa and 150 kPa irrigation. It implies that reduction of fertilization is the feasible practice to mitigate drought stress in fields without stable irrigation resources.

Effects of the buried lamellar tears on the mechanical strength in the welded T joints (T형상용접 이음에서 매몰된 라멜라균열이 용접부의 기계적 강도에 미치는 영향)

  • 고진현
    • Journal of Welding and Joining
    • /
    • v.6 no.4
    • /
    • pp.44-53
    • /
    • 1988
  • The mechanical strengths of buried lamellar tears located near the weld toe in the welded tee joints were evaluated in terms of the loss of load carrying capacity as a function of tear area. In static loading, the load carrying capacity was significantly reduced when tear intercepted over 10% of the cross-sectional area of the welded joints. However, the welded joints containing buried tears still failed at stresses over the yield strength of the base metal in the through-thickness direction in spite of the presence of tears up to 20-25% of the area. Fatigue strength of welded joints containing tears markedly reduced with increasing tear areas. Lehigh lamellar tearing test used in this study to produce speicmens was described in detail. The load carrying cpapacity in static loading was influenced by the reduction of supporting area whereas that in fatigue loading was influenced by the stress-concentration effects of lamellar tears and the reduction of supporting area. In bend tests, the pre-existing lamellar tears always grew up toward the weld toe. However, in fatigue loading, cracks grew up and down simultaneously form both the weld toe and the top of lamellar tears because of stress concentration. In fatigue loading, delaminations and decohesion of inclusion/matrix interface generated in multipass welds provided crack propagation paths and enhanced crack propagation because the tips of delaminations and deconhesios acted as stress raisers.

  • PDF

Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed (II) - Establishment of Intercepting Capacity and Reduction Goal of Overflow Pollution Load - (오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(II) - 차집용량과 월류오염부하 삭감목표 설정 -)

  • Lee, Doojin;Shin, EungBai
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.557-564
    • /
    • 2005
  • The objective of this study is to evaluate a criteria of intercepting capacity and a reduction goal of overflow pollution load in combined sewer system. In the current criteria of intercepting capacity in the domestic sewage facility standard, it is known that three times of peak sewage (Q) in dry period or runoff flow by 2mm/hr is not appropriate since the intercepted flow is estimated by runoff and show different result even in the same watershed. Though a reduction goal of overflow pollution load can be determined from 1) same level of storm-water runoff pollution load in separated storm sewer, 2) less than 5% sewage load in dry weather period, by the domestic sewage facility standard, the simulated results from storm-water model show large differences between two criteria. While it is predicted that sewage pollution load standard three time larger than separated storm sewer standard in high population density and urbanized area, it is shown that separate storm sewer standard larger than sewage pollution load standard in middle population density and developing area. Accordingly, it is proposed that more reasonable intercepting flow and reduction goal of overflows pollution load should be established to minimize discharging pollution load in combined sewer systems. For the purpose, a resonable standard has to be amended by pollution load balance considering the characteristics of a watershed for generation, collection, treatment, and discharging flow.

Estimation of Probability Density Function of Tidal Elevation Data using the Double Truncation Method (이중 절단 기법을 이용한 조위자료의 확률밀도함수 추정)

  • Jeong, Shin-Taek;Cho, Hong-Yeon;Kim, Jeong-Dae;Hui, Ko-Dong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.3
    • /
    • pp.247-254
    • /
    • 2008
  • The double-peak normal distribution function (DPDF) suggested by Cho et al.(2004) has the problems that the extremely high and low tidal elevations are frequently generated in the Monte-Carlo simulation processes because the upper and lower limits of the DPDF are unbounded in spite of the excellent goodness-offit results. In this study, the modified DPDF is suggested by introducing the upper and lower value parameters and re-scale parameters in order to remove these problems. These new parameters of the DPDF are optimally estimated by the non-linear optimization problem solver using the Levenberg-Marquardt scheme. This modified DPDF can remove completely the unrealistically generated tidal levations and give a slightly better fit than the existing DRDF. Based on the DPDF's characteristic power, the over- and under estimation problems of the design factors are also automatically intercepted, too.

Analysis of Shrunken-Interleaved Sequence Based on Cellular Automata (셀룰라 오토마타 기반의 수축-삽입 수열의 분석)

  • Choi, Un-Sook;Cho, Sung-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2283-2291
    • /
    • 2010
  • The shrinking generator which is one of clock-controlled generator is a very simple generator with good cryptographic properties. A nonlinear sequence generator based on two 90/150 maximum length cellular automata can generate pseudorandom sequences at each cell of cellular automata whose characteristic polynomials are same. The nonlinear sequence generated by cellular automata has a larger period and a higher linear complexity than shrunken sequence generated by LFSRs. In this paper we analyze shrunken-interleaved sequence based on 90/150 maximum length cellular automata. We show that the sequence generated by nonlinear sequence generator based on cellular automata belongs to the class of interleaved sequence. And we give an effective algorithm for reconstructing unknown bits of output sequence based on intercepted keystream bits.

Microclimate of Greenhouses Covered with Functional Film (기능성 연질필름 온실의 미기상)

  • Chun, Hee;Choi, Young-Jun;Choi, Young-Ha;Kim, Hark-Joo;Lee, Si-Young;Jeong, Du-Seok;Shin, Yong-Seub;Choi, Chung-Don
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.96-100
    • /
    • 2007
  • There was no difference in total light transmissivity of covering materials. But the light transmittance of J-2 in greenhouse was by 78.25 which was higher than any other film. The high light transmittance of J-2 was come from low water condensation and dust attached in film surface. The ultraviolet light of J-3 was completely intercepted. The ultraviolet transmittance rate of others was from 62 to 76%. In no heating oriental melon cultivation, the air temperature in tunnel was 15 to $21^{\circ}C$ higher than outer, and the soil temperature in tunnel was 20 to $25^{\circ}C$ higher than outer. Air temperature and soil temperature of J-2 were higher than any other film.

A Study on the Allocation and Engagement Scheduling of Air Defense Missiles by Using Mixed Integer Programming (혼합정수계획법을 이용한 요격미사일의 할당 및 교전 일정계획에 관한 연구)

  • Lee, Dae Ryeock;Yang, Jaehwan
    • Korean Management Science Review
    • /
    • v.32 no.4
    • /
    • pp.109-133
    • /
    • 2015
  • This paper considers the allocation and engagement scheduling of air defense missiles by using MIP (mixed integer programming). Specifically, it focuses on developing a realistic MIP model for a real battle situation where multiple enemy missiles are headed toward valuable defended assets and there exist multiple air defense missiles to counteract the threats. In addition to the conventional objective such as the minimization of surviving target value, the maximization of total intercept altitude is introduced as a new objective. The intercept altitude of incoming missiles is important in order to minimize damages from debris of the intercepted missiles and moreover it can be critical if the enemy warhead contains an atomic or chemical bomb. The concept of so called the time window is used to model the engagement situation and a continuous time is assumed for flying times of the both missiles. Lastly, the model is extended to simulate the situation where the guidance radar, which guides a defense missile to its target, has the maximum guidance capacity. The initial mathematical model developed contains several non-linear constraints and a non-linear objective function. Hence, the linearization of those terms is performed before it is solved by a commercially available software. Then to thoroughly examine the MIP model, the model is empirically evaluated with several test problems. Specifically, the models with different objective functions are compared and several battle scenarios are generated to evaluate performance of the models including the extended one. The results indicate that the new model consistently presents better and more realistic results than the compared models.

Response of Gray Rock Cod to the Colored Lights (색광에 대한 볼낙의 반응)

  • YANG Yong-Rhim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.4
    • /
    • pp.330-334
    • /
    • 1983
  • The author carried out an experiment to find out the response of gray rock cod, Sebastes inermis (Cuvier et Valenciennes) to the color light. The experimental tank ($360L{\times}50W{\times}55H\;cm$) was set up in a dark room. Six longitudinal sections with 60 cm intervals are marked in the tank to observe the location of the fish. Water depth in the tank was kept 50 cm level. Light bulbs of 20W at the both ends of the tank projected the light horizontally into the tank. Two different colored filters were selected from four colors of red, blue, yellow, and white, and they were placed in front of the light bulbs to make different colors of light. Light intensity were controlled by use of auxiliary filters intercepted between the bulb and the filter. The fishes were acclimatized in the dark for 50 minutes before they were employed in the experiment. Upon turning on the light, the number of fish in each section was counted 40 times in 30 second intervals, and the mean of the number of fish in each section was given as the gathering rate of the fish. The colors favourited by the fish was found in the order of white, blue, yellow and red. The gathering rate of fish on illumination period was small and comparatively fluctuated with stability. The difference of the gathering rates on two different colors of light was much greater, regardless of illumination period, in day time than in night time.

  • PDF