• Title/Summary/Keyword: inter-view correlation

Search Result 28, Processing Time 0.03 seconds

A Study on the Development of an Infertility Stress Scale (불임 스트레스 척도 개발에 관한 연구)

  • 김선행;박영주;장성옥
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.141-155
    • /
    • 1995
  • The objective of this study was to develop a scale to measure stress in infertile couples and to test its reliability and validity. Prior to item generation, a basic decision was made to conceptualize stress in infertile couples as including two dimensions and four subdimensions. The dimensions were, intrapersonal stress including cognitive and affective stress, and interpersonal stress including marital and social stress. Initially 95 items were generated from the inter-view data of 31 primary or secondary infertile women and from a literature review. These items were analyzed through the Index of Content Validity(CVI) and 69 items were selected which met 70% or more of the CVI. This preliminary Infertility Stress Scale were analyzed for reliability and construct validity. Item analysis and factor analysis were applied for construct validity. Forty items were selected through item analysis. This procedure was based on the inter-item correlation matrix, a corrected average inter-item correlation coefficient(.30~.70), a corrected item to total correlation coefficient (.03 or more) and information about the alpha estimate if this item was dropped from the scale. The result of the initial factor analysis including varimax rotation produced eight factors. Five items deleted because of factor complexity(indiscriminate factor loadings). The secondary factor analysis including varimax rotation produced seven factors that coincided with the conceptual framework posed for the scale developed. The seven factors were labeled as ‘meaning of children’,‘worthiness’,‘tenacious linking’,‘marital satisfaction’,‘sexual satisfaction’,‘familial adjustment’ and ‘social adjustment’. The alpha coefficient relating to internal consistency was .93 for reliability The results of this study suggest that the measurement derived from the Infertility Stress Scale is useful in assessing the stress of infertile couples.

  • PDF

The Reliability and Validity of Useful Field of View Test (UFOV(Useful Field of View test) 검사의 신뢰도 및 타당도 검증)

  • Kwak, Ho-Soung;Jung, Bong-Keun
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.157-163
    • /
    • 2017
  • The aim of the study is to examine the reliability and validity of UFOV, which is a visual driving evaluation tool that has been proven to be reliable and valid in western countries, for the purpose of adapting the tool in a systematic manner to the South Korean population. Two evaluator assessed 23 healthy and 19 stroke patients with UFOV, Trail Making Test A & B(TMT A & B) and Motor Free Visual Perception Test(MVPT) from 7 October 2014 to 25 November, 2014. The researcher analyzed inter-rater reliability, correlation between raters of UFOV with Intraclass correlation coefficient, test-retest reliablility, UFOV with spearman correlation coefficient, concurrent validity, UFOV, TMT A & B and MVPT with spearman correlation coefficient, and discriminative validity, comparison mean scores of UFOV between groups, healthy and stroke with Mann-Whitney U test. UFOV score of participants with stroke had lower compared to the healthy control group. The inter-rater reliability(p<.001), test-retest reliability(p<.01) and concurrent validity(p<.01) was statistically significant. Also discriminant validity was statistically significant(p<.001). Based on this study, Use of UFOV for drivers at risk is essential to prevent future traffic accidents and support driving rehabilitation.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

A Study on the Reliability of the Occupational Job Stress Indices Questionnaire Applied to Koreans (Occupational Job Stress Index의 신뢰성(信賴性) 관(關)한 연구(硏究))

  • Lee, Young-Soo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.19-25
    • /
    • 1980
  • The Occupational Job Stress Indicies Questionnaire is a selfadministered instrument consisting of 48 questions which are designed to collect the perceived Job stress about individual. This questionnaire was translated into Korean and applied to the selected groups of 300 blue collar workers musical manufacture industy for the purpose of assessing the it's reliability from April 1. to July 30, 1980. The results obtained were as follows; 1. The range of reliability coefficients for all indices was. 45-.75 which was lower than .54-.87 of original. 2. The inter-item correlation matrix for all items comprising an index along with the intercorrelation of these items with the items comprising closely related indices. 3. The reliability of JOB SATISFACTION, INTRINSIC REWARDS and IMPORTANCE REWARDS revealed .14-.20 lower than that of original. On the point of view, some items should be adjusted in parallel with acutual situation of Korea through making a cultural comparative study and item factor analysis.

  • PDF

The Design of Motion Estimation Hardware for High-Performance HEVC Encoder (고성능 HEVC 부호기를 위한 움직임추정 하드웨어 설계)

  • Park, Seungyong;Jeon, Sunghun;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.594-600
    • /
    • 2017
  • This paper proposes a global search based motion estimation algorithm for high performance HEVC encoder and its hardware architecture. To eliminate temporal redundancy, motion estimation in HEVC inter-view prediction uses global search and fast search algorithm to search for a predicted block having a high correlation with the current PU in an interpolated reference picture. The global search method predicts the motion of all candidate blocks in a given search area, thus ensuring optimal results, but has a disadvantage of large computation time. Therefore we propose a new algorithm that reduces computational complexity by reusing SAD operation in global search to reduce computation time of inter prediction. As a result of applying the proposed algorithm to standard software HM16.12, the computation time was reduced by 61%, BDBitrate by 11.81%, and BDPSNR by about 0.5% compared with the existing search algorithm. As a result of hardware design, the maximum operating frequency is 255 MHz and the total number of gates is 65.1K.

Comparison of Angle Measurements on Hallux Valgus with Two Different Methods Using Digital Images (디지털 영상을 이용한 무지 외반증 변형각 측정에서 서로 다른 두 계측 방법의 비교)

  • Sung, Il-Hoon;Kim, Ki Chun;Sung, Chang-Ho;Seo, Woo-Young;Lee, Doo-Yeon;Cho, Young A
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.1
    • /
    • pp.40-44
    • /
    • 2013
  • Purpose: To study inter- and intra-observer reliabilities of computerized measurements of the angular parameters of hallux valgus deformity, using two different kinds of software tools for angle measurement on the digital radiography. Materials and Methods: On 35 digital radiographies of standing foot anteroposterior view of hallux valgus, two observers (A, B) independently measured hallux valgus angle (HVA) and 1-2 intermetatarsal angle ($IMA_{1-2}$) twice, using two methods. In method I, an angle was determined from duplicated lines to longitudinal axes made for bisecting line on the target bones with software tool. In method II, an angle was calculated automatically and directly from bisecting lines (longitudinal axes) made on the target bones. We compared two methods using paired t-test to determine significance of differences. Inter- and intraobserver reliabilities were evaluated using the intraclass correlation coefficients (ICC). Results: There were no significant differences between measurements of method I and II for each observer (p>0.05) and intraobserver reliability were good. (ICC>0.9) Inter-observer reliability for method I and II was good of the HVA (ICCs, 0.912 and 0.905) and moderate of the $IMA_{1-2}$ (ICCs, 0.505 and 0.537). There were interobserver differences in HVA of method I and II. Conclusion: No significant difference was found statistically between measurements of method I and II. Both methods I and II would be acceptable to measure angular parameters of hallux valgus deformity.

The New Radiographic Evaluation of Hindfoot Alignment (후족부 정렬의 새로운 방사선학적 평가 방법)

  • Han, Woo-Yeon;Lee, Ho-Seong;Kim, Won-Kyeong;Ahn, Ji-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.169-174
    • /
    • 2012
  • Purpose: There are various methods proposed for the evaluation of the hindfoot alignment. However, due to structural calcaneus variances between patients, it is hard to assess this alignment definitively. Thus, this study proposes a new method for evaluating of the hindfoot alignment and its comparisons to the existing current methods. Materials and Methods: This study includes simple weight bearing hindfoot coronal view radiographs of 120 patients, taken between the time period of March 2008 to November 2009. Among the 120 patients, there was a 1:1 ratio of male to female with an average age of 40. The newly proposed method for evaluating this alignment is to draw a moment arm from the point where the sustentaculum tali meets the medial calcaneus border to the most prominent aspect of the lateral process of the calcaneal tuberosity. The angle produced via the intersection of this moment arm to the mid-longitudinal axis of the tibia is found and used to evaluate the hindfoot alignment. The inter and intra-observer reliability was evaluated using the coefficient of intraclass correlation. This study also investigates the comparisons between the newly proposed method to the traditionally used Saltzman et al hindfoot alignment evaluating technique. Results: The newly proposed method has higher inter and intra-observer reliability than the existing traditional Saltzman et al technique. Conclusion: This new method is recommended over the traditionally used Saltzman et al technique as it has a stronger confidence level and is appropriate for assessing hindfoot alignment in simple radiographs.

A Review on the Job Stress Measurements in Nuclear Power Plant Workers for Human Error Prevention

  • Kim, Seon Soo;Luo, Meiling;Oh, Yeon Ju;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.47-58
    • /
    • 2013
  • Objective: The aim of this study is to review the job stress measurement for applying in nuclear power plants(NPPs). Background: The standard and guideline to evaluate and manage the job stress is insufficient in NPPs. Although job stress might have a negative effect on task performance particularly it can be related with human error in NPPs. Method/Results: This paper considered the objective and subjective stress measurements. One of the questionnaire(Korean Occupational Stress Scale) and the experiment method was investigated to apply in NPPs. KOSS was analyzed about the inter item consistency and correlation with the workload, and relative importance. In the objective evaluation considered the experiment method for the physical and mental job stress and analyzed from the phased point of view. Conclusion/Application: The measurement and criteria to evaluate job stress for operators must be complemented on the job characters and environments in NPPs. This study may support to confirm and manage the job stress in NPPs. The study of more specific methodology on job stress in NPPs is required on the basis of this paper.

Computer Aided Identification of Inter-Layer Faults in Gas Insulated Capacitively Graded Bushing during Switching

  • Rao, M.Mohana;Dharani, P.;Rao, T. Prasad
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.28-34
    • /
    • 2009
  • In a Gas Insulated Substation (GIS), Very Fast Transients (VFTs) are generated mainly due to switching operations. These transients may cause internal faults, i.e., layer-to-layer faults in a capacitively graded bushing as it is one of the most important terminal equipment for GIS. The healthiness of the bushing is generally verified by measuring its leakage current. However, the change in current magnitude/pattern is only marginal for different types of fault conditions. Leakage current monitoring (LCM) systems generate large amounts of data and computer aided interpretation of defects may be of great assistance when analyzing this data. In view of the above, ANN techniques have been used in this study for identification of these minor faults. A single layer perceptron network, a two layer feed-forward back propagation network and cascade correlation (CC) network models are used to identify interlayer faults in the bushing. The effectiveness of the CC network over perceptron and back propagation networks in identification of a fault has been analysed as part of the paper.

Prediction of successful caudal epidural injection using color Doppler ultrasonography in the paramedian sagittal oblique view of the lumbosacral spine

  • Yoo, Seon Woo;Ki, Min-Jong;Doo, A Ram;Woo, Cheol Jong;Kim, Ye Sull;Son, Ji-Seon
    • The Korean Journal of Pain
    • /
    • v.34 no.3
    • /
    • pp.339-345
    • /
    • 2021
  • Background: Ultrasound-guided caudal epidural injection (CEI) is limited in that it cannot confirm drug distribution at the target site without fluoroscopy. We hypothesized that visualization of solution flow through the inter-laminar space of the lumbosacral spine using color Doppler ultrasound alone would allow for confirmation of drug distribution. Therefore, we aimed to prospectively evaluate the usefulness of this method by comparing the color Doppler image in the paramedian sagittal oblique view of the lumbosacral spine (LS-PSOV) with the distribution of the contrast medium observed during fluoroscopy. Methods: Sixty-five patients received a 10-mL CEI of solution containing contrast medium under ultrasound guidance. During injection, flow was observed in the LSPSOV using color Doppler ultrasonography, following which it was confirmed using fluoroscopy. The presence of contrast image at L5-S1 on fluoroscopy was defined as "successful CEI." We then calculated prediction accuracy for successful CEI using color Doppler ultrasonography in the LS-PSOV. We also investigated the correlation between the distribution levels measured via color Doppler and fluoroscopy. Results: Prediction accuracy with color Doppler ultrasonography was 96.9%. The sensitivity, specificity, positive predictive value, and negative predictive value were 96.7%, 100%, 100%, and 60.0%, respectively. In 52 of 65 patients (80%), the highest level at which contrast image was observed was the same for both color Doppler ultrasonography and fluoroscopy. Conclusions: Our findings demonstrate that color Doppler ultrasonography in the LS-PSOV is a new method for determining whether a drug solution reaches the lumbosacral region (i.e., the main target level) without the need for fluoroscopy.