• 제목/요약/키워드: inter-electrode distance

검색결과 30건 처리시간 0.029초

위전도 측정을 위한 전극간 부착거리에 관한 연구 (Influences of Inter-electrode Distance on Electrogastrography Measurements)

  • 한완택;송인호;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.341-346
    • /
    • 2009
  • Cutaneous electrogastrography is the measurement of electrical activity of the stomach on the abdominal surface. The validity of cutaneous electrogastrography is dependent upon the quality of the recording technique. The locations of electrodes are an important issue. We examined the influences of the inter-electrode distance of bipolar leads on electrogastrography measurements. The sensitivity distributions of EGG leads were calculated based on a 2D body fat model and evaluated according to the region of interest sensitivity ratio (ROISR). We simulated the ROISR of the inter-electrode distance in relation to various body fat thicknesses. The distance between the electrodes was proportional to the distance between the ROI and the surface of the abdomen. The results imply that inter-electrode distance can be applied in electrogastrography according to human body fat thickness.

전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구 (The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal)

  • 임경민;송동진
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발 (Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance)

  • 최기원;최규하
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권12호
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

탄뎀 가스메탈아크 용접의 토치 극간거리에 관한 실험적 연구 (A Experiment Study of Torch Distance on Automated Tandem GMA Welding System)

  • 이지혜;김일수;정성명;이종표;김영수;박민호
    • Journal of Welding and Joining
    • /
    • 제30권6호
    • /
    • pp.49-55
    • /
    • 2012
  • The tandem welding process is one of the most efficient welding processes widely used in material joining technique such as manufacturing of strong and durable structures. It facilitates high rate of joint filling with little increase in the overall rate of heat input due to the simultaneous deposition from two electrode wires. The two electrodes in tandem welding process helps in high-efficiency and high productive of welding process. In this study a automated tandem welding system is developed to determine the correlation between cathode and anode and compared with current ratio of the two electrode torch. Three different inter-electrode distances were chosen, 25mm, 35mm and 45mm to perform the experiment with three different current ratio. From the experiment results, the current ratio between two torch has a large impact on width, height and depth of penetration. In addition, a stable bead geometry is obtained when inter-electrode distance is 35mm.

형조 방전가공에서 극간 전압과 가공 안정성에 관한 연구 (A Study on the Gap Voltage and Machining Stability in Diesinking Electrical Discharge Machining)

  • 김광열;이상민;이건기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.429-436
    • /
    • 2003
  • The electrical discharge machining(EDM) with Si electrode instead of Gr or Cu electrode. made enormous effects on the surface. machining time, anti-caustic workpiece surface and so on In this paper. we experimented on the inter-role distance during discharge the electrical phenomenon of inter-pole, the distribution of discharge point. the distribution of off load time. etc., using Si electrode Cu electrode and Gr electrode under the same machining condition. As a result of a large quantity generated exclusive powders. the performance of the EDM using Si electrode. compared with EDM using others. is improved. We show that the quantities of those make far pole-gap discharge and discharge scatter under stable machining status possible.

Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis

  • Choi, Gi-Won;Moon, In-Hyuk;Sung, So-Young;Lee, Mynug-Joon;Chu, Jun-Uk;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1268-1271
    • /
    • 2005
  • This paper proposes a compact-sized surface myoelectric sensor for myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket of the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is composed of a skin interface and a single processing circuit that are mounted on a single package. Since the skin interface has one reference and two input electrodes, and the reference electrode is located in middle of two input electrodes, we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material used for the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering conduction velocity and median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.

  • PDF

Microfludic 플랫폼을 이용한 생체 분자의 voltammetric 분석 (Microfluidic platform for voltammetric analysis of biomolecules)

  • ;한다운;;김용상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1686-1687
    • /
    • 2011
  • A microfabricated chip with in-channel electrochemical cell using interdigitated gold electrode was fabricated for sensitive electrochemical analysis. The gold electrodes were fabricated on glass wafer using thermal evaporator and were covered using PDMS mold containing microchannel for analyte and electrolyte. The active area of each electrode was $250\;{\mu}m{\times}200\;{\mu}m$ with a gap of 200 ${\mu}m$ between the electrodes. Microelectrodes results in maximum amplification of signal, since the signal enhancement effect due to cycling of the reduced and oxidized species strongly depends on the inter electrode distance. Analytes such as methylene blue and guanosine were characterized using the fabricated electrodes and their electrochemical characteristics were compared with conventional bulk electrodes. The device so developed shall find use as disposable electrochemical cell for rapid and sensitive analysis of electroactive species.

  • PDF

전동의수용 근전위 센서 설계 (Design of myoelectrical sensor for myoelectric hand prosthesis)

  • 최기원;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.247-249
    • /
    • 2007
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60㎐ power-line noise, amplifier, and a level circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

  • PDF

근전의수용 소형 표면 근전위 센서의 개발 (Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis)

  • 최기원;성소영;문인혁
    • 전자공학회논문지SC
    • /
    • 제42권6호
    • /
    • pp.67-76
    • /
    • 2005
  • 본 논문에서는 근전의수용 소형 근전위 센서를 제안한다. 근전의수용 근전위 센서를 의수 소켓에 내장시키기 위해서는 소형이어야 한다. 제안된 근전위 센서는 피부와 접촉하는 전극과 신호처리를 위한 회로부가 일체화된 형태로 소형화 하였다. 기준 전극은 두 입력전극의 가운데에 나란히 배치되고, 입력전극은 막대형, 기준전극은 막대형과 원형의 두 가지 형상으로 설계하였다. 두 입력전극 사이의 간격은 근섬유의 근전위 신호의 전도속도와 중심주파수를 고려하여 18mm, 20mm, 22mm 의 세 개의 서로 다른 간격을 가진 전극을 제작하였다. 사용된 전극의 재료는 땀이나 습기에 강한 SUS440 금속을 사용하였다. 신호처리 회로부는 대역통과 필터를 갖는 차동 증폭기, 전원노이즈를 제거하기 위한 대역저지 필터, 교류결합증폭기, 절대평균값 회로로 구성되어 있다. 실험에서는 정상인의 전완에서 근전위 신호를 취득하여 주파수 분석하고, 입력전극 사이의 간격과 기준전극의 형상에 따른 출력특성 평가하였다. 본 논문에서는 실험의 결과로부터 두 입력전극간의 거리가 18mm 이면서, 입력전극의 형상과 기준전극의 형상이 모두 막대형인 표면 근전위 센서가 근전의수에 최적임을 보인다.