• Title/Summary/Keyword: inter-comparison

Search Result 513, Processing Time 0.024 seconds

Agreement and Reliability between Clinically Available Software Programs in Measuring Volumes and Normative Percentiles of Segmented Brain Regions

  • Huijin Song;Seun Ah Lee;Sang Won Jo;Suk-Ki Chang;Yunji Lim;Yeong Seo Yoo;Jae Ho Kim;Seung Hong Choi;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.959-975
    • /
    • 2022
  • Objective: To investigate the agreement and reliability of estimating the volumes and normative percentiles (N%) of segmented brain regions among NeuroQuant (NQ), DeepBrain (DB), and FreeSurfer (FS) software programs, focusing on the comparison between NQ and DB. Materials and Methods: Three-dimensional T1-weighted images of 145 participants (48 healthy participants, 50 patients with mild cognitive impairment, and 47 patients with Alzheimer's disease) from a single medical center (SMC) dataset and 130 participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset were included in this retrospective study. All images were analyzed with DB, NQ, and FS software to obtain volume estimates and N% of various segmented brain regions. We used Bland-Altman analysis, repeated measures ANOVA, reproducibility coefficient, effect size, and intraclass correlation coefficient (ICC) to evaluate inter-method agreement and reliability. Results: Among the three software programs, the Bland-Altman plot showed a substantial bias, the ICC showed a broad range of reliability (0.004-0.97), and repeated-measures ANOVA revealed significant mean volume differences in all brain regions. Similarly, the volume differences of the three software programs had large effect sizes in most regions (0.73-5.51). The effect size was largest in the pallidum in both datasets and smallest in the thalamus and cerebral white matter in the SMC and ADNI datasets, respectively. N% of NQ and DB showed an unacceptably broad Bland-Altman limit of agreement in all brain regions and a very wide range of ICC values (-0.142-0.844) in most brain regions. Conclusion: NQ and DB showed significant differences in the measured volume and N%, with limited agreement and reliability for most brain regions. Therefore, users should be aware of the lack of interchangeability between these software programs when they are applied in clinical practice.

Comparison of early wound healing using modified papilla preservation technique between enamel matrix derivative and recombinant human fibroblast growth factor

  • Yohei Nakayama;Shinichi Tabe;Kazuma Igarashi;Satoshi Moriya;Tsuyoshi Katsumata;Ryo Kobayashi;Shuta Nakagawa;Tomoko Nishino;Namiko Fukuoka;Kota Hosono;Mai Yamasaki;Yosuke Yamazaki;Moe Ogihara-Takeda;Shoichi Ito;Yumi Saito;Arisa Yamaguchi;Yuto Tsuruya;Mizuho Yamazaki-Takai;Shoichi Yoshino;Hideki Takai;Yorimasa Ogata
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.4
    • /
    • pp.236-252
    • /
    • 2024
  • Purpose: Enamel matrix derivative (EMD) has demonstrated beneficial effects on wound healing following surgery. However, the effects of recombinant human fibroblast growth factor 2 (rhFGF-2) in periodontal regeneration therapy have not been extensively studied. This retrospective study was conducted to compare the wound healing outcomes of the modified papilla preservation technique (mPPT) between EMD and rhFGF-2 therapies. Methods: A total of 79 sites were evaluated for early wound healing using the modified early wound healing index (mEHI), which included 6 items: incision, fibrin clotting, step, redness, swelling, and dehiscence. A numeric analog scale, along with postoperative images of the 6 mEHI items, was established and used for the evaluations. The inter-rater reliability of the mEHI was assessed via intraclass correlation coefficients (ICCs). After adjusting for factors influencing the mPPT, the differences in mEHI scores between the EMD and rhFGF-2 groups were statistically analyzed. Additionally, radiographic bone fill (RBF) was evaluated 6 months after surgery. Results: The ICC of the mEHI was 0.575. The mEHI, redness score, and dehiscence scores were significantly higher in the rhFGF-2 group (n=33) than in the EMD group (n=46). Similar results were observed in the subgroup of patients aged 50 years or older, but not in those younger than 50 years. In the subgroup with non-contained bone defects, related results were noted, but not in the subgroup with contained bone defects. However, early wound healing did not correlate with RBF at 6 months after surgery. Conclusions: Within the limitations of this study, the findings suggest that early wound healing following the use of mPPT with rhFGF-2 is somewhat superior to that observed after mPPT with EMD. However, mEHI should be improved for use as a predictive tool for early wound healing and to reflect clinical outcomes after surgery.

Comparison of Multi-Satellite Sea Surface Temperatures and In-situ Temperatures from Ieodo Ocean Research Station (이어도 해양과학기지 관측 수온과 위성 해수면온도 합성장 자료와의 비교)

  • Woo, Hye-Jin;Park, Kyung-Ae;Choi, Do-Young;Byun, Do-Seung;Jeong, Kwang-Yeong;Lee, Eun-Il
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.613-623
    • /
    • 2019
  • Over the past decades, daily sea surface temperature (SST) composite data have been produced using periodically and extensively observed satellite SST data, and have been used for a variety of purposes, including climate change monitoring and oceanic and atmospheric forecasting. In this study, we evaluated the accuracy and analyzed the error characteristic of the SST composite data in the sea around the Korean Peninsula for optimal utilization in the regional seas. We evaluated the four types of multi-satellite SST composite data including OSTIA (Operational Sea Surface Temperature and Sea Ice Analysis), OISST (Optimum Interpolation Sea Surface Temperature), CMC (Canadian Meteorological Centre) SST, and MURSST (Multi-scale Ultra-high Resolution Sea Surface Temperature) collected from January 2016 to December 2016 by using in-situ temperature data measured from the Ieodo Ocean Research Station (IORS). Each SST composite data showed biases of the minimum of 0.12℃ (OISST) and the maximum of 0.55℃ (MURSST) and root mean square errors (RMSE) of the minimum of 0.77℃ (CMC SST) and the maximum of 0.96℃ (MURSST) for the in-situ temperature measurements from the IORS. Inter-comparison between the SST composite fields exhibited biases of -0.38-0.38℃ and RMSE of 0.55-0.82℃. The OSTIA and CMC SST data showed the smallest error while the OISST and MURSST data showed the most obvious error. The results of comparing time series by extracting the SST data at the closest point to the IORS showed that there was an apparent seasonal variation not only in the in-situ temperature from the IORS but also in all the SST composite data. In spring, however, SST composite data tended to be overestimated compared to the in-situ temperature observed from the IORS.

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Morphological comparison between aquaculture and natural populations for development of the new varieties of Ecklonia cava (감태(Ecklonia cava Kjellman) 신품종 개발을 위한 양식 개체군과 자연 개체군의 형태 비교)

  • Kim, Seung-Oh;Heo, Jin Seok;Hwang, Eun Kyoung;Hwang, Mi Sook;Lee, Sang-Rae;Oak, Jung Hyun
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.707-718
    • /
    • 2019
  • Ecklonia cava Kjellman, which has recently gained popularity due to the spread of farming techniques, is expected to be developed in various varieties in the future. There exist increased needs for research on the basis of natural populations and inter-regional morphological variations. We compared the morphology of the aquaculture and natural populations from 16 coastal areas in Korea. The 18 traits found suitable for distinguishing varieties were selected from 14 measurement traits and 4 ratios related to the main morphology and characteristics of primary blade, secondary blade, and stipe. In the cluster analysis, Janggil (E4) and Sorok (S7) showed significant differences from those of the same coastal region. Two groups, including Suyou (Q6, Q8, and Q10) which was the second year of farming, of the rest of the populations from East sea and southern coast were distinguished. Three populations of Jeju were divided into a regional group. In the principal component analysis (PCA), a large number of populations from East sea and Southern coast appeared in the center with aquaculture populations. PC1 and PC2 associated with traits of secondary blade index, stipe length and diameter, stipe length/primary blade length, primary blade length and width, secondary blade number, secondary blade length and width, divided E4, S7 and populations of Jeju region. As a result, the 18 characters of this study were found to be useful as criteria for discrimination of populations with significant differences in each coastal region, and these populations were expected to be candidates for new varieties.

A Performance Comparison of the Mobile Agent Model with the Client-Server Model under Security Conditions (보안 서비스를 고려한 이동 에이전트 모델과 클라이언트-서버 모델의 성능 비교)

  • Han, Seung-Wan;Jeong, Ki-Moon;Park, Seung-Bae;Lim, Hyeong-Seok
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.3
    • /
    • pp.286-298
    • /
    • 2002
  • The Remote Procedure Call(RPC) has been traditionally used for Inter Process Communication(IPC) among precesses in distributed computing environment. As distributed applications have been complicated more and more, the Mobile Agent paradigm for IPC is emerged. Because there are some paradigms for IPC, researches to evaluate and compare the performance of each paradigm are issued recently. But the performance models used in the previous research did not reflect real distributed computing environment correctly, because they did not consider the evacuation elements for providing security services. Since real distributed environment is open, it is very vulnerable to a variety of attacks. In order to execute applications securely in distributed computing environment, security services which protect applications and information against the attacks must be considered. In this paper, we evaluate and compare the performance of the Remote Procedure Call with that of the Mobile Agent in IPC paradigms. We examine security services to execute applications securely, and propose new performance models considering those services. We design performance models, which describe information retrieval system through N database services, using Petri Net. We compare the performance of two paradigms by assigning numerical values to parameters and measuring the execution time of two paradigms. In this paper, the comparison of two performance models with security services for secure communication shows the results that the execution time of the Remote Procedure Call performance model is sharply increased because of many communications with the high cryptography mechanism between hosts, and that the execution time of the Mobile Agent model is gradually increased because the Mobile Agent paradigm can reduce the quantity of the communications between hosts.

The Effects of Brand Experience and Personality on Consumer-Brand Relationships, Attachment, and Loyalty - A Comparison of Domestic and Global Brand Coffee Shops - (브랜드 체험 및 개성이 소비자-브랜드 관계, 브랜드 애착, 브랜드 충성도에 미치는 영향 - 국내외 브랜드 커피전문점 비교 -)

  • Hong, Ju-Young;Kim, Seong-Soo;Han, Ji-Soo
    • Culinary science and hospitality research
    • /
    • v.22 no.5
    • /
    • pp.231-251
    • /
    • 2016
  • This study examined the effect of brand experience and personality on customer-brand relationships, brand attachment, and brand loyalty in domestic and global coffee shop brands. By comparing inter-structural relationships among factors between domestic brands and global brands, this study also provided strategic implications and directions for the effective marketing strategy of coffee shop brands. Data were collected through a self-administered survey of the consumers aged 20's to early 40's who used domestic and global brand coffee shops in Seoul and Kyunggi between August 1, 2014 and August 30, 2014. 500 surveys were distributed and 495 surveys were returned. Among them, data from 493 surveys were used for the analysis. The results from this study are as follows. First, it was found that the Think of experiences in coffee shop had a greater effect on consumer-brand relationship than the Sense-Feel. Second, the Sophistication of brand personality in coffee shop had a greater effect on consumer-brand relationship than the Excitement. Third, only Think of experience in coffee shop significantly impacted brand attachment, but Sense-Feel did not impact brand attachment. Fourth, only Excitement of brand personality in coffee shop significantly impacted brand attachment, but Sophistication did notact on brand attachment. Fifth, the consumer-brand relationship had a greater effect on brand loyalty than did brand attachment. Finally, the differences from a comparison analysis of domestic brands and global brands of coffee shop are as follows. In domestic brands, only the Sophistication of brand personality in coffee shop significantly impacted consumer-brand relationship. In global brands, the brand personality in coffee shop did not impact on consumer-brand relationship.

Comparison of Response Systems and Education Courses against HNS Spill Incidents between Land and Sea in Korea (국내 HNS 사고 대응체계 및 교육과정에 관한 육상과 해상의 비교)

  • Kim, Kwang-Soo;Gang, Jin Hee;Lee, Moonjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2015
  • As the type of Hazardous and Noxious Substances(HNS) becomes various and the transport volume of HNS increases, HNS spill incidents occur frequently on land and the sea. In view of various damages to human lives and properties by HNS spills, it is necessary to educate and train professional personnel in preparation for and response to potential HNS spills. This study shows the current state of response systems and education courses against HNS spill incidents on land and the sea to compare those with each other between land and sea in Korea. Incident command system on land are basically similar to that at sea, but leading authority which is responsible for combating HNS spills at sea is changeable depending on the location of HNS spill, as it were, Korea Coast Guard(KCG) is responsible for urgent response to HNS spill at sea, while municipalities are responsible for the response to HNS drifted ashore. Education courses for HNS responders on land are established at National Fire Service Academy(NFSA), National Institute of Chemical Safety(NICS), etc., and are diverse. Education and training courses for HNS responder at sea are established at Korea Coast Guard Academy(KCGA) and Marine Environment Research & Training Institute(MERTI), and are comparatively simple. Education courses for dangerous cargo handlers who work in port where land is linked to the sea are established at Korea Maritime Dangerous Goods Inspection & Research Institute(KOMDI), Korea Port Training Institute(KPTI) and Korea Institute of Maritime and Fisheries Technology(KIMFT). Through the comparison of education courses for HNS responders between land and sea, some recommendations such as extension of education targets, division of an existing integrated HNS course into two courses composed of operational level and manager level with respective refresh course, on-line cyber course and joint inter-educational institute course in cooperation with other relevant institutes are proposed for the improvement in education courses of KCG and KOEM(Korea Marine Environment Management Corporation) to educate and train professionals for combating HNS spills at sea in Korea.

Evaluation of Community Land Model version 3.5-Dynamic Global Vegetation Model over Deciduous Forest in Gwangneung, Korea (광릉 활엽수림에서 Community Land Model 3.5-Dynamic Global Vegetation Model의 평가)

  • Lim, Hee-Jeong;Lee, Young-Hee;Kwon, Hyo-Jung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.2
    • /
    • pp.95-106
    • /
    • 2010
  • The performance of Community Land Model version 3.5 - Dynamic Global Vegetation Model (CLM-DGVM) was evaluated through a comparison with the observation over temperate deciduous forest in Gwangneung, Korea. Influence of plant phenology, composition of plant functional type, and climate variability on carbon exchanges was also examined through sensitivity test. To get equilibrium carbon storage, the model was run for 400 years driven by the observed atmospheric data at the deciduous forest of the year 2006. We run the model for 2006 with the equilibrium carbon storage at Gwangneung forest and compared the model output with the observation. A comparison of leaf area index (LAI) between the model and observation indicated that the simulated phenology poorly represented the timing of budburst, leaf-fall, and evolution of LAI. Senescence of the phenology was delayed about four weeks and the simulated maximum LAI (of 5.8 $m^2$ $m^{-2}$) was greater than the observed value (of 4.5 $m^2$ $m^{-2}$). The overestimated LAI contributed to overestimation of both gross primary productivity (GPP) and ecosystem respiration $(R_e)$ through increased photosynthesis and foliar autotropic respiration $(R_a)$, respectively. Despite the discrepancy between the simulated and observed LAI, the simulated tree carbon storage amounts were comparable with the reported values at the site. Change in plant phenology from the simulated to the observed reduced more than six weeks of the plant growth period, resulting in the decreased amount of GPP and $R_e$. These values, however, were still higher (~10% of GPP and 40% of $R_e$) than the observed values. The effect of change in plant functional type composition (from dominant temperate deciduous forest to the coexistence of temperate deciduous and needle leaf forests) on the estimated amount of GPP and $R_e$ was marginal. The influence of climate variability on carbon storage amounts was not significant. The simulated inter-annual variation of GPP and $R_e$ from 1994 to 2003 depended on annual mean air temperature and total radiation but not on precipitation. Other deficiencies of CLM3.5-DGVM have been discussed.

Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom (인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향)

  • Wang, Jihwan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.495-501
    • /
    • 2014
  • The objective of this study was to evaluate the differences and reproducibility of Hounsfield unit (HU) value and volume measurements on different computed tomography (CT) scanner types and different collimations by using a gelatin phantom. The phantom consisting of five synthetic simulated calculus spanning diameters from 3.0 mm to 12.0 mm with 100 HU was scanned using a two-channel multi-detector row CT (MDCT) scanner, a four-channel MDCT scanner, and two 64-channel MDCT scanners. For all different scanner types, the thinnest possible collimation and the second thinnest collimation was used. The HU values and volumes of the synthetic simulated calculus were independently measured three times with minimum intervals of 2 weeks and by three experienced veterinary radiologists. ANOVA and Scheff$\acute{e}$ test for the multiple comparison were performed for statistical comparison of the HU values and volumes of the synthetic simulated calculus according to different CT scanner types and different collimations. The reproducibility of the HU value and volume measurements was determined by calculating Cohen's k. The reproducibility of HU value and volume measurements was very good. HU value varied between different CT scanner types, among different beam collimations. However, there was not statistically significant difference. The percent error (PE) decreased as the collimation thickness decreased, but the decrease was statistically insignificant. In addition, no statistically significant difference in the PEs of the different CT scanner types was found. It can be concluded that the CT scanner type insignificantly affects HU value and the volumetric measurement, but that a thinner collimation tends to be more useful for accurate volumetric measurement.