• Title/Summary/Keyword: intensity profile

Search Result 366, Processing Time 0.027 seconds

Image Analysis of Micro Lesions According to Grid Frequency After Removal of Moire Artifact (Moire artifact 제거 후 그리드 주파수에 따른 미세병변의 영상분석)

  • Lee, Sang-Ho;Kim, Gyoo-Hyung;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • Morphological information such as shape and margin of micro lesion is important information for diagnosis of disease in clinical imaging. In this study, we investigated the morphological changes of the micro lesions by comparing the contrast and area in grid suppressed DR images according to grid frequency. In the profile analysis of the image, the mass showed an average intensity variation of 8.6 ~ 72.4 after suppression, The higher the grid frequency, the more the contrast was increased. However, in the images obtained using 103 lp / inch, which is a grid frequency less than the sampling frequency, the contrast of the mass in the vertical direction decreased after suppression. In the binary image, the area change of the mass was also large. As a result, the shape, size, and margin of the mass changed. In the case of very small calcification, the higher the grid frequency is the larger the change in contrast, so that a clear image can be obtained in the post-suppression image. However, we could confirm that the margin of the lesion was blurred and the lesion was lost in some of the images using the 103 lp / inch grid. The higher the frequency of the grid, The change of the contrast of fiber occurred largely and clear boundary was confirmed. The decrease of the number of pixels was small and morphological change was small. In conclusion, when using a grid frequency that is not suitable for the sample frequency, morphological changes or lesion loss of micro lesions in the post- suppression image may give the possibility of misdiagnosis in diagnosis and differentiation of the image.

Analysis of Bacterial Community Structure in Gossi Cave by Denaturing Gradient Gel Electrophoresis (DGGE) (DGGE를 이용한 동굴 생태계 세균 군집 구조 분석)

  • 조홍범;정순오;최용근
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.213-219
    • /
    • 2004
  • The bacterial community of water stream, soil and guano in Gossi cave was examined by using PCR amplified the 16S rDNA-denaturing gradient gel electrophoyesis (DGGE). In this study, the genetic diversity and the similarity of bacterial community between open area and non - open area toy cave tour were investigated, and the seasonable variation pattern was compared each other. DGGE is attractive technique, as it sepayate same length dsDNA according to sequence variation typical 16S rDNA genes. The diversity and similarity of bacterial community in cave was analyzed by GC341f and PRUN518r primer sets foy amplification of V3 region of eubacteria 16S rDNA. The specific DGGE band profile of the cave water gives the possibility that the specific bacterial cell can be adapting to the specific cave environment and living in the cave. The DGGE band profiles of all samples with guano were compared and analyzed by image analyzer, in which mutual band profile was compared to be and the band intensity of guano was the highest. From these result, it is thought that the guano was main nutrient source and influenced on the community structure of the cave environment where is nutritionally limited. Pseudomonas sp. NZ060, Pseudomonas pseudoalcaligenes, uncultured Variovorax sp. and soli bacterium NS7 were identified to be on some sample from analysing DNA sequence of some DGGE band.

A Customer Profile Model for Collaborative Recommendation in e-Commerce (전자상거래에서의 협업 추천을 위한 고객 프로필 모델)

  • Lee, Seok-Kee;Jo, Hyeon;Chun, Sung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.67-74
    • /
    • 2011
  • Collaborative recommendation is one of the most widely used methods of automated product recommendation in e-Commerce. For analyzing the customer's preference, traditional explicit ratings are less desirable than implicit ratings because it may impose an additional burden to the customers of e-commerce companies which deals with a number of products. Cardinal scales generally used for representing the preference intensity also ineffective owing to its increasing estimation errors. In this paper, we propose a new way of constructing the ordinal scale-based customer profile for collaborative recommendation. A Web usage mining technique and lexicographic consensus are employed. An experiment shows that the proposed method performs better than existing CF methodologies.

Characteristics of the Nd:YAG laser with stimulated brillouin scattering phase conjugate mirror (유도 브릴루앙 산란 위상공액 거울을 이용한 Nd:YAG 레이저 발진기의 출력특성)

  • 이동원;이성구;박승현;공홍진
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.548-553
    • /
    • 2002
  • We have investigated the output characteristics of a Nd:YAG oscillator with a Stimulated Brillouin Scattering phase conjugation mirror (SBS-PCM). FC-75 is used as an SBS gain medium and Cr:YAG (T=50%) as a Q-switcher. The SBS-PCM consists of an SBS-cell and a simple plano-convex focusing lens system. For the case of not using a Q-switcher, an SBS-cell doesn't work as a phase conjugation mirror. For the case of using a Q-switcher, the energy characteristics remains nearly the same whether using the SBS-cell or not using it. The pulse width is reduced from 50 ns to 40 ns by an SBS-PCM. When the SBS-cell is used with a Q- switcher, the SBS-cell works very well as a phase conjugation mirror and its beam-profile is improved dramatically. And in order to explain the progression of beam-profile, we propose a simple model based on the nonlinear reflectivity of the SBS-PCM, whose reflectivity is dependent on the pumping intensity at the focal plane.

Spectroscopic Study of the Symbiotic Star CI Cyg

  • Hyung, Siek
    • Journal of the Korean earth science society
    • /
    • v.35 no.5
    • /
    • pp.313-323
    • /
    • 2014
  • We secured the high dispersion spectra of the symbiotic star CI Cyg. The HI, HeI, and HeII line profiles were analyzed using the relatively long exposure data including 1800 sec (Sep. 12, 1998, phase=0.90), 3600 sec (Aug. 12, 2002, ${\phi}=0.47$), and 1800 sec (Oct. 21, 2009, ${\phi}=0.54$). Although a minor outburst was reported in 2008, our three observation periods were generally known to be quiescent in earlier photometric studies. With the help of hydrodynamic simulations, we identified the two emission zones responsible for the blue- and red-shifted line components: (a) an accretion disk around a hot white dwarf star which consists of the outer cool HeI emission zone and the inner hot HeII emission part, and (b) a high density zone near the inner Lagrangian point responsible for the HeI line flux variation and the broadening of its line profile. The HeII line fluxes indicate that the HeII emission zone of the accretion disk is relatively stable, implying a constant gas inflow from the giant star throughout the quiescent period. The 2002 HeI data showed that the notable mass flow activity through the inner Lagrangian point occurred during this period and its flux intensity became strongest, whereas the HeII line width in the same period indicates that its flow activity forced the accretion disk to expand. The [OIII] lines were observed in 1998 but not detected in 2002 and 2009, implying the disappearance of the low density zone. Based on our kinematical studies upon the line profiles, we conclude that CI Cyg was stable in 1998 among the three observation periods selected in this research.

Comparison of GC Profile and Sensory Properties of Fermented Cheese Flavor Concentrates and Cheese Varieties (자연치즈와 치즈향 농축물의 화학적, 관능적 분석에 의한 향미 비교)

  • 한영실
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.6
    • /
    • pp.925-931
    • /
    • 1995
  • Volatile compounds in Cheddar, Emmentaler, Parmesan and Roquefort cheese and cheese aroma were concentrated using a microsteam distillation-extraction apparatus and those compounds were analyzed with GC. The lipase-treated cheese aroma concentrates showed significantly higher level of short-chain free fatty acids than natural ripened cheese. The sensory properties of rancidity was high in Emmemtaler and Parmesan. Acidity and fruitness were shown high score in Roquefort. Correlation of free fatty acids and cheese flavor 'sharpness, rancidity and soapy' appear to be related(r=0.8239, 0.8918 and 0.7503), respectively. Methyl ketones, the most striking flavor components of Roquefort cheese showed high amounts in the series 2-heptanone > 2-nonanone > 2-pentanone > 2-undecanone. And the intensity of the Roquefort taste sensation 'acidity and fruitness' is linearly correlated with the methyl ketone concentrations(r=0.9284, r=0.9659).

  • PDF

Two Cases Using the Praat-Based Automatic Voice Analysis Program as an Alternative to CSL (사례 적용 Praat 기반 CSL 대체 자동화 음성분석 프로그램)

  • Kang, Young Ae;Chang, Jae Won;Koo, Bon Seok
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.2
    • /
    • pp.87-93
    • /
    • 2021
  • There are a number of voice analysis programs around the world. Domestic voice analysis is performed by relying heavily on specific commercial program. We intend to develop coding for voice analysis using Praat and apply it to clinical practice. This study consisted of Experiment 1 and Experiment 2. Experiment 1 was the development of automated voice analysis coding based on Praat. The coding was largely divided into a recording, an analysis, and a storage section. Experiment 2 was applied to the voice analysis of 2 male patients pre- and post-operation with this coding. The analysis parameters of this coding provided 26 parameters for vowel /a/, nine parameters for sentence analysis, and a total of 4 parameters for voice range profile analysis. In two male patients, the pitch and the intensity increased, the voice quality improved, and the sentence length decreased after surgery. The coding was well made, so the output was good in real time. The code is automated as much as possible to block manual errors and increases convenience and efficiency by generating the result sheet in real time.

Addition of $B_2O_3$ precursors and their effect on texture and surface roughness of $La_2Zr_2O_7$ buffer layers

  • Kim, Young-Kuk;Yoo, Jai-Moo;Chung, Kook-Chae;Shin, Pyung-Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.2
    • /
    • pp.20-23
    • /
    • 2008
  • [ $La_2Zr_2O_7$] (LZO) buffer layers were deposited on biaxially textured Ni-W substrates by chemical solution deposition method (CSD). In this study, the effect of $B_2O_3$ addition on texture and surface roughness of LZO films was investigated. The alkoxide-based precursor solution was employed to synthesize the precursor solution of LZO and the solution was coated on biaxially textured Ni-W substrates and subsequently annealed at $900^{\circ}C$ for crystallization. The pure LZO film without $B_2O_3$ addition showed a (222) reflection in the X-ray diffraction (XRD) profile. The intensity of (222) reflection was enhanced and more rough surface was obtained after further repetition of coating. Contrary to this, the LZO film prepared by $B_2O_3$ added precursor solution shows well-developed (400) reflection peak in the XRD profile and excellent biaxial texture (${\Delta}{\theta}=4.3^{\circ}$, ${\Delta}{\phi}=6.8^{\circ}$). The surface roughness of LZO films were also improved by addition of $B_2O_3$ even after multicoating ($R_{rms}{\sim}3.1nm$). It was shown that the LZO film with smooth surface and biaxial texture was grown on the biaxially textured Ni-W substrates with addition of $B_2O_3$ in the precursor solution.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Comparison of Normalization Methods for Defining Copy Number Variation Using Whole-genome SNP Genotyping Data

  • Kim, Ji-Hong;Yim, Seon-Hee;Jeong, Yong-Bok;Jung, Seong-Hyun;Xu, Hai-Dong;Shin, Seung-Hun;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.6 no.4
    • /
    • pp.231-234
    • /
    • 2008
  • Precise and reliable identification of CNV is still important to fully understand the effect of CNV on genetic diversity and background of complex diseases. SNP marker has been used frequently to detect CNVs, but the analysis of SNP chip data for identifying CNV has not been well established. We compared various normalization methods for CNV analysis and suggest optimal normalization procedure for reliable CNV call. Four normal Koreans and NA10851 HapMap male samples were genotyped using Affymetrix Genome-Wide Human SNP array 5.0. We evaluated the effect of median and quantile normalization to find the optimal normalization for CNV detection based on SNP array data. We also explored the effect of Robust Multichip Average (RMA) background correction for each normalization process. In total, the following 4 combinations of normalization were tried: 1) Median normalization without RMA background correction, 2) Quantile normalization without RMA background correction, 3) Median normalization with RMA background correction, and 4) Quantile normalization with RMA background correction. CNV was called using SW-ARRAY algorithm. We applied 4 different combinations of normalization and compared the effect using intensity ratio profile, box plot, and MA plot. When we applied median and quantile normalizations without RMA background correction, both methods showed similar normalization effect and the final CNV calls were also similar in terms of number and size. In both median and quantile normalizations, RMA backgroundcorrection resulted in widening the range of intensity ratio distribution, which may suggest that RMA background correction may help to detect more CNVs compared to no correction.