• Title/Summary/Keyword: intensity measures

Search Result 399, Processing Time 0.022 seconds

Prediction of hysteretic energy demands in steel frames using vector-valued IMs

  • Bojorquez, Eden;Astorga, Laura;Reyes-Salazar, Alfredo;Teran-Gilmore, Amador;Velazquez, Juan;Bojorquez, Juan;Rivera, Luz
    • Steel and Composite Structures
    • /
    • v.19 no.3
    • /
    • pp.697-711
    • /
    • 2015
  • It is well known the importance of considering hysteretic energy demands for the seismic assessment and design of structures. In such a way that it is necessary to establish new parameters of the earthquake ground motion potential able to predict energy demands in structures. In this paper, several alternative vector-valued ground motion intensity measures (IMs) are used to estimate hysteretic energy demands in steel framed buildings under long duration narrow-band ground motions. The vectors are based on the spectral acceleration at first mode of the structure Sa($T_1$) as first component. As the second component, IMs related to peak, integral and spectral shape parameters are selected. The aim of the study is to provide new parameters or vector-valued ground motion intensities with the capacity of predicting energy demands in structures. It is concluded that spectral-shape-based vector-valued IMs have the best relation with hysteretic energy demands in steel frames subjected to narrow-band earthquake ground motions.

Effects of High-intensity Intermittent Training and Moderate-intensity Training on Cardiopulmonary Capacity in Canoe and Kayak Paddlers during 8 Weeks

  • Kim, Ah-Ram;Shin, Won-Seob
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.3
    • /
    • pp.307-314
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the effects of high intensity intermittent training on cardiopulmonary capacity in canoe and kayak paddlers. METHODS: A total of 16 canoe and kayak paddlers were participated in this study. Experimental group(n=8) was performed high-intensity intermittent training and control group(n=8) was moderate intensity training. All subjects performed a treadmill test in order to compare the difference before and after the intervention. Finishing the test, all subjects were measured to their heart rate(HR), forced vital capacity(FVC), forced expiratory volume in one second (FEV1) and forced expiratory ratio(FEV1/FVC). Recovery of heart rate(RHR) was calculated using the HR. HR and pulmonary flow values was measured before and during the intervention period per 2, 4, 6 and 8 weeks. To compare the differences over time between experimental group and the control group, used(time${\times}$group) two-way repeated measures ANOVA. One-way repeated ANOVA was performed to determine where differences over time within-group. RESULTS: One-way repeated ANOVA revealed a significant difference in the experimental and control group. In experimental group, %RHR3min and FEV1 were significantly increased after 4 weeks(p<.05). Also, %RHR1min, FVC and FEV1/FVC were significantly increased after 6 weeks(p<.05). In control group, %RHR1min, %RHR3min, FVC, FEV1 and FEV1/FVC were significantly increased after 6 weeks(p<.05). CONCLUSION: Not only moderate training but also high-intensity intermittent training contributes to cardiopulmonary capacity in canoe and kayak paddlers. Although high-intensity intermittent training is very short time, the training has high degree of efficiency. Therefore, developed this training in the future, it will be better to improve the cardiopulmonary capacity for athletes and healthy people.

Method of Estimating the Ground-Motion Intensity Measures at a Nearby Site by using the Time-domain Transformation of Site Response (지진파형의 시간영역 부지응답특성 변환을 통한 인접부지의 지진동세기 추정 방법)

  • Yun, Kwan-Hee;Park, Dong-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.219-226
    • /
    • 2010
  • Current earthquake alert notification for immediate post-earthquake procedures for the critical facilities is exclusively dependent on the ground-motion intensity measures observed at the seismic station located within the site. This practice is prune to false notification due to a noise and problems of missing and poor quality records of the seismic station. The credibility of the earthquake alert notification can be enhanced by utilizing the multiple transformed records of the nearby seismic stations at other sites interconnected to the same earthquake monitoring system by a network. The time-domain transformation of the site-response between the seismic stations is implemented by convoluting the nearby records with a pair of forward and inverse FIR filters designed for the site response relative to a seismic basement. The transformed records from the nearby seismic stations can be used to estimate the ground-motion intensity measures missing at the site or to evaluate the data quality along with other various possible applications in the area of geoscience and earthquake engineering.

Dose Planning Study of Target Volume Coverage with Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma: Penang General Hospital Experience

  • Vincent Phua, Chee Ee;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng;Ung, Ngie Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2243-2248
    • /
    • 2013
  • Background: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

Voice Activity Detection using Motion and Variation of Intensity in The Mouth Region (입술 영역의 움직임과 밝기 변화를 이용한 음성구간 검출 알고리즘 개발)

  • Kim, Gi-Bak;Ryu, Je-Woong;Cho, Nam-Ik
    • Journal of Broadcast Engineering
    • /
    • v.17 no.3
    • /
    • pp.519-528
    • /
    • 2012
  • Voice activity detection (VAD) is generally conducted by extracting features from the acoustic signal and a decision rule. The performance of such VAD algorithms driven by the input acoustic signal highly depends on the acoustic noise. When video signals are available as well, the performance of VAD can be enhanced by using the visual information which is not affected by the acoustic noise. Previous visual VAD algorithms usually use single visual feature to detect the lip activity, such as active appearance models, optical flow or intensity variation. Based on the analysis of the weakness of each feature, we propose to combine intensity change measure and the optical flow in the mouth region, which can compensate for each other's weakness. In order to minimize the computational complexity, we develop simple measures that avoid statistical estimation or modeling. Specifically, the optical flow is the averaged motion vector of some grid regions and the intensity variation is detected by simple thresholding. To extract the mouth region, we propose a simple algorithm which first detects two eyes and uses the profile of intensity to detect the center of mouth. Experiments show that the proposed combination of two simple measures show higher detection rates for the given false positive rate than the methods that use a single feature.

자기 공명 영상의 고신호 구역에 관한 오공약침 치료의 임상적 연구

  • Lim, Jeong-A;Lee, Sung-Yong;Na, Won-Min;Moon, Hyung-Cheol;Yoo, Kwan-Suk;Kim, Sung-Chul
    • Journal of Pharmacopuncture
    • /
    • v.9 no.3 s.21
    • /
    • pp.37-46
    • /
    • 2006
  • Objective : This study was designed to find out the effect of scolopendrid aquacupuncture on low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging. Methods : The 30 patients who had a diagnosis of high intensity zone by lumbar-MRI and admitted to Gwangju oriental medical hospital in wonkwang university from January 2005 to August 2004 were observed. The symptom of inpatients is low back pain with or without sciatica. We treated 30 patients by scolopendrid aquacupuncture besides the general conservative treatment of oriental medicine. Results and Conclusion : The scolopendrid aquacupuncture treatment led to improvement in the pain and symptom of disability as determined by all efficacy measures. After scolopendrid aquacupuncture treatment, there was improvement in VAS, ROM and SLRT. This results suggest that scolopendrid aquacupuncture is good method for treatment of low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging.

The Measurement Method of Reflected Intensity of Radiation for High Precision Laser Range Finder (고정밀 레이저 변위기용 반사 광량 측정 기법)

  • Bae, Young-Chul;Cho, Eui-Joo;Lee, Hyen-Jae;Kim, Sung-Hyen;Kim, Hyeon-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.1
    • /
    • pp.34-40
    • /
    • 2009
  • The phase delay of output signal of APD(avalanche photo diode) caused by intensity of reflected light which comes from target. These difference of phase delay is an one of the main reason of measurement error, but there is no reasonable measurement meter and method to detect it. In this paper, to solve the problem, we propose and implement a method to measure the intensity of radiation. The method measures DC voltage which is proportional to the reflected intensity of radiation and come out from APD in receiver by realtime.

  • PDF

The Effects of Self Stretching on Shoulder Pain and Shoulder Flexibility of Hospital Nurses (자가 스트레칭이 병원 간호사의 어깨 통증과 어깨 유연성에 미치는 효과)

  • Jeong, Eun-Ju;Chae, Young Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.4
    • /
    • pp.268-274
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effects of self stretching on shoulder pain and should flexibility of nurses. Methods: Forty two nurses who work in a university hospital participated in the study; an intervention (n=22) and a control group (n=20). The nurses of intervention group carried out a 4-week self stretching program. All participants completed 1 item NRS scale for pain intensity and 1 item 4-Likert scale for pain intensity. Both shoulder flexibilities of the nurses were measured by back and reach test. All measurements were done at baseline, 2 week, 4 week during the program and 2 week following the program. The data was analyzed by frequency, percentage, ${\chi}^2$-test, t test, Repeated measures ANOVA using SPSS 12.0. Results: There were significant differences in the pain intensity (p<.001) and frequencies(p<.001) between two groups. Also, Left and right shoulder flexibilities of the intervention group significantly increased than those of the control group (p<.001 and p=.002 respectively). Conclusion: The results showed that self stretching reduce the intensity and frequency of shoulder pain and increase both shoulder flexibilities. Thus, self stretching is recommended as an intervention to improve shoulder function of hospital nurses.

Effect of Difference in Warm-Up Intensity During 75%1RM Bench Press Exercise on Number of Repetitions, Total Work, and RPP

  • Jeong, Hwan Jong;Kim, Ki Hong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.130-136
    • /
    • 2021
  • The purpose of this study was to investigate the effect of the intensity of warm-up exercise on the physiological response and exercise performance during resistance exercise. For this purpose, 8 male college students with at least 1 year of experience in resistance movement were selected. The warm-up condition was set to NON condition (preparatory exercise not performed), 3 set condition, 6 set condition, and 9 set condition, and the intensity was different for each set. After warm-up, 75% 1RM of main exercise was performed, and blood pressure and heart rate were measured immediately after exercise to measure RPP. The number of repetitions and total work for each condition were measured as the number of repetitions and momentum during the main exercise. The measured data were analyzed by repeated measures two-way ANOVA. As a result, although there was no difference in Rate Pressure Product according to the warm-up conditions, the number of repetitions and total amount of exercise showed the highest in the 3-set condition. Therefore, it is thought that the number and intensity of warm-up exercises should be set appropriately during resistance exercise, and warm-up of 3 sets or more during resistance exercise is thought to decrease exercise performance.

Bayesian approach for the accuracy evaluating of the seismic demand estimation of SMRF

  • Ayoub Mehri Dehno;Hasan Aghabarati;Mehdi Mahdavi Adeli
    • Earthquakes and Structures
    • /
    • v.26 no.2
    • /
    • pp.117-130
    • /
    • 2024
  • Probabilistic model of seismic demand is the main tool used for seismic demand estimation, which is a fundamental component of the new performance-based design method. This model seeks to mathematically relate the seismic demand parameter and the ground motion intensity measure. This study is intended to use Bayesian analysis to evaluate the accuracy of the seismic demand estimation of Steel moment resisting frames (SMRFs) through a completely Bayesian method in statistical calculations. In this study, two types of intensity measures (earthquake intensity-related indices such as magnitude and distance and intensity indices related to ground motion and spectral response including peak ground acceleration (PGA) and spectral acceleration (SA)) have been used to form the models. In addition, an extensive database consisting of sixty accelerograms was used for time-series analysis, and the target structures included five SMRFs of three, six, nine, twelve and fifteen stories. The results of this study showed that for low-rise frames, first mode spectral acceleration index is sufficient to accurately estimate demand. However, for high-rise frames, two parameters should be used to increase the accuracy. In addition, adding the product of the square of earthquake magnitude multiplied by distance to the model can significantly increase the accuracy of seismic demand estimation.