• Title/Summary/Keyword: integration length

Search Result 229, Processing Time 0.025 seconds

Classification Analysis of Road Network-Based Land Use Considering Spatial Structure (공간구조를 고려한 도로망 기반 토지이용의 분류분석)

  • Kim, Hye-Young;Jun, Chul-Min
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.1
    • /
    • pp.24-34
    • /
    • 2014
  • To understand urban space and make appropriate plans, the integrative analyses considering road and land use simultaneously are required. In addition, studies that involve both horizontal and vertical spaces must be taken into consideration. Therefore, the purpose of this study is to conduct a classification analysis of road network-based land use considering spatial structure. The methods of this study were as follows; first, a space syntax theory considering the structure of road network was introduced for roads. For land use, to consider both horizontal and vertical development densities of residential and commercial buildings were used. And the explanatory power of three variables-Euclidean distance, global integration and length-reflected global integration-were compared. Third, based on road as an appropriate variable, modified-IPA was conducted with land use and the results were categorized into four areas. The proposed method was applied to Gangnam-gu, a CBD area in Seoul, and results were analyzed and visualized using GIS.

The Design of Broadband PIFA for Hand-Held Mobile Phones (이동통신 광대역 PIFA 안테나 설계 및 해석)

  • 김상준;이대헌;박천석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.855-862
    • /
    • 2003
  • This paper suggests the PIFA structure modified antenna in which short-circuit plate is located between planar element and ground plane, in order to solve the problem of narrow band of existing internal antenna, PIFA. It is also suggested that internal antenna has the perturbation in the patch to broaden the frequency bandwidth. It is possible that the antenna is installed into the mobile telephone with a low profile condition(h=0.015 λ) to use internally, and acquired desired bandwidth(5.2 %) through double resonance structure, remodeling the PIFA that is already well-known as an internal antenna. This paper investigated how characteristic is affected by the feeding point(Yf, Zf), short strip plate(Zs), short strip width(Ws), perturbation width(w), length(d), short plate height(h), dielectric($\varepsilon$$\_$r/) to be slim type antenna. It is compared with existing PIFA bandwidth, and is suggested pattern as the H.E plane. It is simulated using the Microwave Studio of the CST Inc. based on FIM(Finite Integration Method) method and analyzed antenna characteristic following the variation each parameters. The result proved the practical use of PIFA antenna by comparing the measured and simulated data of the antenna.

A new method of predicting hotspot stresses for longitudinal attachments with reduced element sensitivities

  • Li, Chun Bao;Choung, Joonmo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.379-395
    • /
    • 2021
  • For the complicated structural details in ships and offshore structures, the traditional hotspot stress approaches are known to be sensitive to the element variables of element topologies, sizes, and integration schemes. This motivated to develop a new approach for predicting reasonable hotspot stresses, which is less sensitive to the element variables and easy to be implemented the real marine structures. The three-point bending tests were conducted for the longitudinal attachments with the round and rectangular weld toes. The tests were reproduced in the numerical simulations using the solid and shell element models, and the simulation technique was validated by comparing the experimental stresses with the simulated ones. This paper considered three hotspot stress approaches: the ESM method based on surface stress extrapolation, the Dong's method based on nodal forces along a weld toe, and the proposed method based on nodal forces perpendicular to an imaginary vertical plane at a weld toe. In order to study the element sensitivities of each method, 16 solid element models and 8 shell element models were generated under the bending and tension loads, respectively. The element sensitivity was analyzed in terms of Stress Concentration Factors (SCFs) in viewpoints of two statistical quantities of mean and bias with respect to the reference SCFs. The average SCFs predicted by the proposed method were remarkably in good agreement with the reference SCFs based on the experiments and the ship rules. Negligibly small Coefficients of Variation (CVs) of the SCFs, which is measure of statistical bias, were drawn by the proposed method.

Performance Evaluation of Full Scale Reinforced Subgrade for Railroad with Rigid Wall Under Static Load (정하중 재하 시 실물 강성벽 일체형 철도보강노반의 성능평가)

  • Kim, Dae-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.31-42
    • /
    • 2015
  • The Reinforced subgrade for railroad (RSR) was constructed for one way railway line with the dimension of 5 m high, 6 m wide and 20 m long to evaluate its performance under train design load. The RSR has characteristics of short length (0.3-0.4 H) of reinforcement and rigid wall, 30 and 40 cm vertical spacing of reinforcement installation. To enhance economics and constructability, three kinds of connections (welding, hinge & bolt, bold wire) were also designed to realize the integration between rigid wall and reinforced subgrade. Two times of static loading tests were done on the full size railroad subgrade. The maximum applied pressure was 0.98 MPa (the maximum test load 5.88 MN), which corresponds to 19.6 times of the design load for railroad subgrade, 50 kPa. The performance on the RSR was evaluated with the safety on the failure, subgrade bearing capacity and settlement, horizontal displacement of wall, and reinforcement strain. Based on the full scale test, we confirmed that the RSR with the conditions of 0.35 H (35% of height) short reinforcement length, hinge & bolt type connection for integration between rigid wall and reinforced subgrade, and 40cm vertical spacing of reinforcement installment shows good performance under train design load.

Analysis of VTS Operators' Situational Awareness Based on In-Field Observation and Subjective Rating Methods (현장관찰법과 자기보고법에 기초한 VTS 관제사의 상황인식 분석)

  • Lee, Jae-Sik;Kim, Jung-Ho;Jang, En-Kyu
    • Journal of Navigation and Port Research
    • /
    • v.40 no.6
    • /
    • pp.375-384
    • /
    • 2016
  • This study aimed to specify Vessel Traffic System(VTS) operators' situational awareness(SA) tasks and examine differences in subjective ratings for three levels of SA. Data for relative frequencies of SA tasks were collected by using direct in field observation. Subjective rating scores were obtained using a questionnaire method and compared in terms of VTS operator's gender and length of service career. The results are as follows. First, it was found that the VTS operators perform information perception task elements more frequently than those for information integration and prediction. Second, VTS operators tended to show subjectively lower evaluation scores for prediction than information perception or integration. Third, male VTS operators rated their SA ability higher than females. Fourth, the male VTS operators more than 15 years of career service showed higher subjective rating scores than those with under 5 years of service. Female VTS operators with different levels of career service showed a similar level of subjective rating scores. These results suggest that the frequency of SA related tasks and subjective SA evaluation can differ in terms of SA levels and individual differences.

Production of Thrombopoietin Gene Targeted Clones by Homologous Recombination at $\beta$-casein Locus of Primary Bovine Ear Skin Fibroblasts

  • Mira Chang;Oh, Keon-Bong;Lee, Kyung-Kwang;Han, Yong-Mahn
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2003.10a
    • /
    • pp.86-86
    • /
    • 2003
  • Research has been in progress for more than a decade to production of useful proteins by genetic modification in cattle. However, the levels of protein production in transgenic cattle have been reported very low. To enhance protein production in transgenic animal, we tried homologous recombination to donor cells for production of transgenic clone cattle through nuclear transfer procedure. Thus, we constructed the two targeting vectors of human thrombopoietin (TPO) at bovine $\beta$-casein locus using homologous recombination with 13.6 kb and 9.6 kb homology. In two targeting vectors, positive selection was through the neomycin resistance gene and negative selection was by the diphtheria toxin (DT). Gene targeting was attempted in bovine embryonic fibroblasts (bEF) and bovine ear skin fibroblasts (bESF). To determine the most appropriate concentration of neomycin for bEF and bESF, G4l8 resistance was confirmed by culturing the cells in various concentrations of the drug and both of the cells were optimally selected at $900 \mu g/ml$ of neomycin. The transfected bEF and bESF by the targeting vectors were colonized efficiently at the ratio of DNA to transfection reagent such as $4 \mu g$:2 ${mu}ell$ and $1 \mu g$:$2 \mu l$. Comparing number of healthy clones from passage 4 to passage 8, bESF (17%) persist in culture for much longer than bEF (6%). The two gene-targeted bESF clones of 30 random-integrated clones with 9.6 kb homology length were confirmed, however, nothing was out of 72 random integration clones with 13.6 kb homology length, The DT also worked more efficiently in clones transfected with the vector of 9.6 kb homology length. Our data suggests that the choice of donor cell for long culture period should be considered to obtain targeted cell clone, and the gene-targeting frequency and the DT working efficiency are dependent on the length of target homology.

  • PDF

Experimental Studies on Bond and Splice Performance of Splice Sleeve for Connecting Rebar (철근연결용 스플라이스 슬리브의 이음 및 부착성능에 대한 실험적 연구)

  • Kang, Duk Man;Park, Yong Gul;Lee, Hyeon Gi;Moon, Do Young
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.257-264
    • /
    • 2017
  • The PC (Precast Concrete) construction method is a technique where concrete members that have been produced in a plant are constructed on site. Thus, continuity and secure integration of a structure that can be obtained by connecting rebars at splicing joint for PC members are the main areas of concern for this method. To evaluate the splicing and bonding performance according to application of a splice sleeve for connecting rebar in this research study, the diameter of rebar, development length, grouting strength etc. were set as variables. The performance and stiffness of splicing according to the development length of grout strength were measured and evaluated. In addition, by conducting comparative analysis on each of the variables, the factors that affected the splice sleeve for connecting rebar were discussed. The results confirmed that the strength and stiffness of the splice sleeve for connecting rebar were significantly affected by the development length while the increase in performance according to grout strength was not as significant.

EVALUATION OF BONE RESPONSE BY RESONANCE FREQUENCY ANALYSIS OF ANODIZED IMPLANTS

  • Roh Hyun-Ki;Heo Seong-Joo;Rhyu In-Chul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.745-750
    • /
    • 2005
  • Statement of problem. Resonance frequency analysis has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were $Br{\aa}nemark$ Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were $75.0{\pm}3.4$ and $68.7{\pm}8.1$ for control group. Mean and SO of ISQ values 12 weeks after implant insertion were $73.2{\pm}4.7$ for test group and $72.6{\pm}3.9$ for control group. There were no statistically significant differences between groups in ISQ values after 3 months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

Integration of 4.5' Active Matrix Organic Light-emitting Display with Organic Transistors

  • Lee, Sang-Yun;Koo, Bon-Won;Jeong, Eun-Jeong;Lee, Eun-Kyung;Kim, Sang-Yeol;Kim, Jung-Woo;Lee, Ho-Nyeon;Ko, Ick-Hwan;Lee, Young-Gu;Chun, Young-Tea;Park, Jun-Yong;Lee, Sung-Hoon;Song, In-Sung;Seo, O-Gweon;Hwang, Eok-Chae;Kang, Sung-Kee;Pu, Lyoung-Son;Kim, Jong-Min
    • Journal of Information Display
    • /
    • v.7 no.4
    • /
    • pp.21-23
    • /
    • 2006
  • We developed a 4.5" 192${\times}$64 active matrix organic light-emitting diode display on a glass using organic thin-film transistor (OTFT) switching-arrays with two transistors and a capacitor in each sub-pixel. The OTFTs has bottom contact structure with a unique gate insulator and pentacene for the active layer. The width and length of the switching OTFT is 800${\mu}m$ and lO${\mu}m$ respectively and the driving OTFT has 1200${\mu}m$ channel width with the same channel length. On/off ratio, mobility, on-current of switching OTFT and on-current of driving OTFT were $10^6,0.3{\sim}0.5$ $cm^2$/V·sec, order of 10 ${\mu}A$ and over 100 ${\mu}A$, respectively. AMOLEDs composed of the OTFT switching arrays and OLEDs made using vacuum deposition method were fabricated and driven to make moving images, successfully.

Growth Response on the Euonymus fortunei 'Emelad' n 'Gold' as affected by Artificial Plantings Soil Properties during Dry Spring Season (봄철 건조기 용기형 벽면녹화에서 식재지반 조성에 따른 황금줄사철의 적응성)

  • Ju, Jin-Hee;Kim, Hea-Ran;Park, Heon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1299-1305
    • /
    • 2014
  • For evaluating the effect of various artificial planting soil properties on the Euonymus fortunei 'Emelad'n Gold' growth, a container green wall system experiment was conducted in a wall of greenhouse at Konkuk University, Glocal campus. The experimental artificial planting grounds were prepared with different organic soil conditioner ratios (Control, $A_4O_1$, $A_2O_1$ and $A_1O_1$) and with drought tolerance and an ornamental value Euonymus fortunei 'Emelad'n Gold' was planted. The soil and plant characteristics were investigated from April to Jun 2010. The volumetric soil moisture contents were significantly increasing order as the amount of organic soil conditioner level increased in order to $A_1O_1$ > $A_2O_1$ > $A_4O_1$ > Control. At 4 treatment, soil chemical properties were inversely related to organic soil container ratios increase. The differences of root collar caliper, number of branch, and survival rate between the organic soil conditioner ratio were not significantly affected by organic soil conditioner. But, plant height, internode length, leaf length and leaf width were significantly shorter on plants planted $A_1O_1$ than plants planted other treatments. Therefore, Euonymus fortunei 'Emelad'n Gold' had good growth response regardless of organic soil conditioner ratio and the plant is expected to be a highly valuable shrub for the green wall system if it should be considered in integration with stormwater retention or as a soil conditioner for increasing soil water contents in artificial planting soil.