해양플랜트용 H-120 등급 방화 댐퍼의 성능 실험 (Performance Experiment of H-120 Class Fire Damper for Offshore)

  • 박창수
    • 한국산업융합학회 논문집
    • /
    • 제20권5호
    • /
    • pp.425-430
    • /
    • 2017
  • This study propose CAE analysis of fire damper and design of the damper control system. Through the design of the damper system for ANSYS-CFX heat transfer. As a result of the analysis, continuance equation of the damper control. Climate system. Finaily, We have obtained a fire damper solution by using orthogonal array. The fire damper of the set of fixture and alveolus are made by using a CAE software. Also, the optimum design offshore structures. The new H-120 class fire damper was designed. In the near future, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500mm on the unexposed side as specified test standard.

Influence of Electrical Aging on Space Charge Dynamics of Oil-Impregnated Paper Insulation under AC-DC Combined Voltages

  • Wang, Yan;Li, Jian;Wu, Sicheng;Sun, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1512-1519
    • /
    • 2013
  • Oil-impregnated paper is a major type of insulation used in oil-filled converter transformers for both traditional and new energy systems. This paper presents and analyzes the results of the experiment conducted on the electrical aging of oil-impregnated paper under AC-DC combined voltages using the pulsed electro-acoustic (PEA) technique. The formation and dynamics of space charge affected the performance of insulation material. The electrical aged oil-paper insulation was obtained through electrical aged experiments under the voltages. Based on the PEA technique, measurements were carried out when the oil-paper insulation system was subjected to different stressing and aging times. The space charge dynamics in the bulk of the oil-paper insulation system with different aging times were measured and analyzed. Characteristic parameters such as the total charge injection amount, the total charges of fast moving and slow moving, and the distortion factor of electric field were calculated and discussed. Results show that the longer electrical aging time, the more charges trapped in the bulk of aging sample. It leads to larger distortion factor of electric field in the bulk of aging samples and accelerate degradation of oil-paper insulation under AC-DC combined voltages.

실측 실험을 통한 단열문의 열성능 평가 (Thermal Performance Assessment of Insulated door by experiment.)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.47-52
    • /
    • 2011
  • Currently, Exterior wall's U-value about building envelope is 0.36 W/$m^2K$(Central Region), but window's one is 2.1 W/$m^2K$ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/$m^2{\cdot}K$ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it's a small proportion of the door frame.

건축단열재 생산시스템 브레이커 마찰특성 (Friction Characteristics for Construction thermal insulation manufacturing system Breaker)

  • 손재환;강해동;노규익;장근석;최원식
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.61-65
    • /
    • 2014
  • Construction heat insulating material for construction is used in large amounts in industry. In the manufacturing process of this insulation material, a thermal insulation material is completed while a polymer in a liquid state passes through Hall breaker. At this time, the quality and form of a product are determined by a hole in the breaker according to the oil pressure of the fluid and the change of the flow velocity. The friction wear action with regard to partner movement between the two levels of quality of materials affects the performance and the lifetimes of machine parts. In this study of a friction test, SM45C, which is a material used to create brake holes, was used. PVC was used to create the specimen. Moreover, an experiment divided a lubricous state and an unlubricated condition. The resulting value over the load of a pin, the revolving speed of a disk, and the standby state of an experimental result disk could be acquired.

PD Occurrence Characteristics according to Voltage and Time in Solid Insulator

  • Park, Sung-Hee;Shin, Dal-Woo;Lim, Kee-Joe;Park, Young-Guk;Kang, Sung-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권1호
    • /
    • pp.10-14
    • /
    • 2003
  • The occurrence of partial discharge (PD) in solid dielectrics is very harmful because it leads to the deterioration of insulation by electrical, chemical, and thermal reactions as a combined action of the discharged ions bombarding the surface and by the action of chemical compounds that are formed by the discharge. Consequently, if any defects are present in the solid insulation system, performance decreases until the system breaks down. Therefore, removing or suppressing the defect is very important. Voids are a typical defect in the solid insulation system and are very harmful because they deteriorate insulation. As a basic step, studying the properties of PD in voids is important because an accurate knowledge of these properties is required to estimate the deterioration of voids. In this paper, the correlation between the size of voids and internal PD is discussed as a function of the time of the applied voltage and its magnitude. Magnitude, repetition rate, average discharge power, and average discharge current of PD in specimens with large voids were found to be larger than the others in this experiment. The smaller specimens had voids when the magnitude and number of PDs were reduced.

네팔 해비타트(HfH_Nepal) 생태주택 보급현황과 성능개선실험 연구 - 떠라이 평원지역을 중심으로 - (Experiment for the Performance Improvement of Eco House Provided by Habitat for Humanity Nepal(HfH_Nepal) - Case Study of Terai Plain Region, Nepal -)

  • 임윤택
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.103-112
    • /
    • 2013
  • The Federal Democratic Republic of Nepal(Nepal) is one of the poorest country in the world. People in Nepal are having lots of housing problems including the lack of housing provision. Even Habitat for Humanity Nepal (HfH_Nepal) has developed various programs to diffuse ecological housing, still there are many problems due to financial and technological shortage. The purpose of this study is to verify the effects of suggestion of performance improvement for HfH_Nepal eco house with introduction of the housing situation and efforts to provide sustainable housing by HfH_Nepal in Terai plain. Ideas on CGI sheet roof with poor insulation, double panel bamboo wall and adobe brick wall which can overcome structural and waterproof flaws of the thin single panel bamboo wall. The experiment result shows that both ideas adapted to adobe brick house reduces daily temperature range 50.8% and humidity adjust effect. For the effective provision of adobe brick house, compressive strength was tested for the bricks made with locally available fiber materials. Brick with jute displayed 41.1% betterment than plain brick with closest packing condition while coconut and straw showed 25.1% and 7.9% improvement respectively. Technical and economic problems brought up during the building and experiment process were listed and countermeasures established. This kinds of building prototype houses and experiments can improve the living conditions of people in developing countries with little supplement of resources. Furthermore, consideration of locally available and affordable material can help the social and ecological sustainability in the world.

단열 파우더를 채용한 LNGCC의 BOR예측에 관한 연구 (A Study on the Boil-Off Rate Prediction of LNG Cargo Containment Filled with Insulation Powders)

  • 한기철;황순욱;조진래;김준수;윤종원;임오강;이시복
    • 한국전산구조공학회논문집
    • /
    • 제24권2호
    • /
    • pp.193-200
    • /
    • 2011
  • 본 연구를 통해 superlite라 불리는 단열 파우더를 채용한 NO96 멤브레인 타입 LNG선 단열 화물창의 만선항해 시 LNG의 BOR(Boil-Off Rate) 예측모델을 제시하였다. LNGCC(LNG Cargo Containment)의 비정상상태 열전달 FEM모델은 만선항해 시 대기 및 해수 조건을 반영하고 복잡한 화물창 단열구조에 균질화 기법을 적용하여 구축하였다. BOR은 만선항해중 LNGCC 내부로 침입하는 총 열량을 이용하여 평가되었으며, 주요 변수에 따른 BOR의 변화는 파라메트릭 열전달해석을 통하여 분석하였다. 그리고 파라메트릭 BOR 특성해석 결과를 토대로 LNG선의 탱크 크기, 단열층의 두께 그리고 superlite의 열전도율을 함수로 하는 BOR 예측모델을 유도하였다. 비선형 과도 열전달해석을 통해 직접 구한 BOR과의 비교를 통해 유도한 예측모델은 최대 1% 이내의 상대오차를 나타내었다.

울/나일론 tra-biz 의류용 직물 소재의 열적 쾌적성과 착용특성 (Thermal Comfort and Tactile Wearing Performance of Wool/nylon Fabrics for Tra-biz Garment)

  • 김현아
    • 한국의류산업학회지
    • /
    • 제18권6호
    • /
    • pp.878-888
    • /
    • 2016
  • In this study, wool/nylon(50/50%) blend yarn and its fabrics for tra-biz(complex word of travel+business) garment were prepared, and its wear comfort characteristics were investigated through thermal manikin and human-body wearing experiment. In addition, tactile wearing performance from fabric mechanical properties and the dimensional stability and the pilling of the fabric specimen during wearing and dry-cleaning were measured and compared with those of wool 100% fabric specimen. Heat keepability of the wool/nylon(50/50%) blend fabric by thermal manikin experiment was superior than that of wool 100% fabric, this result was verified with human-body wearing experiment and its result coincided well with this experimental result. Tactile wearing performance of the wool/nylon(50/50%) fabric from fabric mechanical properties measured by FAST system was better than that of the wool 100% fabric. The dimensional stability of the wool/nylon(50/50%) fabric was more stable than that of the wool 100% fabric. Because relaxation shrinkage was lower and hygral expansion of wool 100% fabric was more high. However, the breathability and pilling property of the wool/nylon(50/50%) fabric were inferior than those of the wool 100% fabric. The possibility of application for tra-biz garment of wool/nylon(50/50%) blend fabric was observed because of good heat keepability, tactile wearing performance and washing fastness.

단열 페인트 첨가제로써 중공형 실리카 나노입자의 크기에 따른 효과 (Size Effect of Hollow Silica Nanoparticles as Paint Additives for Thermal Insulation)

  • 김지수;김영훈
    • 청정기술
    • /
    • 제28권1호
    • /
    • pp.18-23
    • /
    • 2022
  • 에너지 절약을 위한 연구 중 단열 기술 분야에서는 공기의 낮은 열전도도를 활용한 연구가 이뤄지고 있으며 널리 상용화 되고 있다. 본 연구에서는 입자 내부에 공기층을 갖는 중공형(hollow) 형태의 실리카 나노 입자를 제조하여 공기층 크기가 단열 성능에 미치는 영향에 대해 고찰하였다. Polystyrene 주형법을 이용하여 졸-겔공정을 통해 속이 빈 중공형 실리카 나노 입자(Hollow silica nanoparticles)를 제조하였고, 입자를 5 wt %로 도료에 첨가한 후 열전달 실험을 통해 단열 성능을 확인하였다. 기존 페인트에 입자를 혼합하여 약 15 %이상의 단열효율을 나타냈으며, 내부 공기층의 크기가 큰 입자가 작은 입자에 비해 5% 높은 단열 성능을 나타냈다. 이번 연구를 통해 내부 크기에 따른 단열효과의 차이를 보여줌으로써, 중공형 형태의 입자를 첨가제나 도료 제조에 사용하는 경우 단열효과를 높이기 위해 매질 내에서 입자가 공기층을 최대로 이룰 수 있도록 입자의 크기를 고려해야함을 제시한다.

완충재의 종류에 따른 공동주택 바닥충격음 차단성능에 관한 실험연구 (An Experiment Study on Floor-Impact Sound Insulation by Resilient Materials in Apartment Buildings)

  • 윤세철;오종민
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.217-225
    • /
    • 2005
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for nine apartment buildings. The floor-impact sound levels were measured for twenty-five On-dol floor structures and various factors which influence the floor-impact sound were analyzed.