• Title/Summary/Keyword: insulation oil

Search Result 258, Processing Time 0.022 seconds

Measurement of Electromagnetic Wave Generated by Partial Discharges in an Insulation Oil (유중 부분방전에 의한 방사전자파의 측정)

  • Park, Dae-Won;Lee, Jung-Yoon;Cho, Hyang-Eun;Kim, Min-Su;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1453-1458
    • /
    • 2011
  • This paper dealt with the measurement and analysis of electromagnetic waves generated by partial discharges in insulation oil to develop insulation diagnostic techniques for power transformer. Two types of narrow-band monopole antennas with the resonant frequency of 500 MHz and 1 GHz were designed and fabricated. We simulated defects which consist of a needle electrode with curvature radius of 10 ${\mu}m$ and a plane electrode with diameter of 60 mm in insulation oil. From the experiment, the maximum output voltage of the fabricated antennas was measured; 620 $mV_{max}$ for 500 MHz resonant frequency and 920 $mV_{max}$ for 1 GHz resonant frequency.

  • PDF

The Evaluation of Characteristics for Insulating Oil Using the Distribution Transformer (배전용 변압기 절연유의 특성 비교 평가)

  • Lee, Byung-Sung;Park, Young-Keun;Kim, Dong-Myung;Kim, Pil-Hwan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.97-99
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

Modeling of Heat Transfer Equations for Estimation of Temperature Variations Inside the Oil Transport Pipe Line (원유 수송관 내부의 온도 변화 예측 을 위한 열전달 방정식의 모델링)

  • Jin, J.J.;Chung, H.T.;Bae, J.S.;Lee, S.O.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.300-303
    • /
    • 2008
  • In the present study, the simple form of the heat transfer equation were suggested to estimate the temperature variation inside the oil pipe in order to determine the thickness of the insulating materials to retain the working oils below the critical temperature. The conservation of the thermal energy at arbitrary time were modeled to one dimensional unsteady equation with the empirical formula or data. The calculating results for non-insulation case showed that the temperature were very sensitive to the thermal convection by the velocity of the external wind. For insulation case, the insulation material which has higher density and specific heat, lower thermal conductivity should be chosen with more brighter coloring outside the pipe in order to retain the working oils below the critical temperature.

  • PDF

Application of Dielectric Spectroscopy Measurements for Estimating Moisture Content in Power Transformers

  • Ekanayake, Chandima;Gubanski, Stanislaw M.;Fernando, M.A.R.M.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.81-89
    • /
    • 2004
  • Frequency Domain Spectroscopy (FDS) measurements were performed on pressboard samples containing different moisture contents and on insulation system of power transformers. The results were used for evaluating sensitivity of the so-called X - Y model, which is applied for estimating moisture content in transformer insulation using the results of FDS measurements. Based on the observations of this analysis a simplified model, called X model, was introduced in which the presence of spacers in transformer insulation has been neglected. Finally, reliability of the X model was assessed by comparing estimates of moisture contents based on FDS measurements on field installed power transformers with moisture contents obtained from chemical analyses of their oil samples.

Evaluation of Insulating Oil by Terahertz Time Domain Spectroscopy (테라헤르츠파 분광법에 의한 절연유 특성 평가)

  • Kim Geun-Ju;Jeon Seok-Gy;Sun Jong-Ho;Jin Yun-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.8
    • /
    • pp.411-416
    • /
    • 2006
  • A new method on the evaluation of insulation oil was proposed. Terahertz time-domain spectroscopy (THz-TDS) was applied to investigate the properties of the insulating oil. For the diagnostics of oil degradation, three kinds of oils have been analyzed by THz-TDS. The degraded oil showed different optical and electrical constants compared with a new one. Generally, the power absorption coefficient, the refractive index, the dielectric constant and loss $tan{\delta}$ of the oil increase as the aging of insulating oil proceed. And the characteristics of two kind of insulation oil, 1-4 and 7-4, was compared in terahertz spectral region. Difference in refractive index and complex dielectric constant has been observed between the samples. The results of this study suggest that THz-TDS is a promising new means for evaluating degradation and identification of insulating oil.

Analysis of the Insulation Resistance Trend according to the Installation Environment of the Electric Wiring of the Melting Furnace (용해로 전기배선의 설치환경에 따른 절연저항 추이 분석)

  • Suk Bong Ko;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.15-22
    • /
    • 2023
  • In this study, the process and the environment of a melting furnace, located in Workplace A in Chungnam Province was inspected, and the insulation resistances of electrical circuits and motors were measured, and their changes over five years (2017-2021) were analyzed. It was found that the exhaust fan, oil pumps #A and #B, and heater were installed in 2010. Their insulation resistances decreased from 2017. Specifically, the insulation resistance of Oil Pump #A decreased from 100 (㏁) in 2018 to 20(㏁) in 2021, an 80% reduction. The fast decrease in insulation resistance was due to the high temperature of the melting furnace affecting surrounding the electrical facilities. A safety management scheme on the electrical facility of the melting furnace was proposed.

Analysis of Propagation Characteristics of Acoustic Signal in Insulation Oil (음향신호의 유중 전파특성 분석)

  • Yun, Min-Young;Park, Kyoung-Soo;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.114-119
    • /
    • 2016
  • This paper dealt with the propagation characteristics of acoustic signal in insulation oil for the purpose of improving the reliability of AE (acoustic emission) method used for condition monitoring of oil-immersed transformers. A discharge source was placed in insulation oil and AE sensors ($f_c$ :140 kHz) were attached on the oil tank to study the changes of velocity and propagation path with the depth and distance. The average velocity was 1,436 m/s and the velocity decreased with the increase of depth from the oil surface to 430 mm. The propagation paths were classified into three sections by the shortest reflection path of the detected signal. The minimum distinguishable distance in each section was 70 mm. It was also verified that PD (partial discharge) with a magnitude over than 500 pC can be detected by the AE sensors.

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

Monitoring method of transformer insulationg oil using pulsed-laser and photodiode (펄스레이저 및 광다이오드를 이용한 변압기 절연유의 절연감시법)

  • Cho, J.S.;Yang, D.M.;An, K.S.;Yoon, S.H.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2130-2132
    • /
    • 1999
  • This paper is research for the practicability of instrument which can apply to the transformer on the spot with the criteria of insulation oil with the method of measuring the volume of $H_2O$ in the insulation oil by playing insulation oil with the significant role for precaution diagnosis on breakdown of transformer among power system into Nd:YAG laser.

  • PDF

Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil (절연유에서 부분방전에 의한 극초단파 신호 특성분석)

  • Ju, Hyoung-Jun;Goo, Sun-Geun;Park, Ki-Jun;Han, Ki-Seun;Yoon, Jin-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.