• Title/Summary/Keyword: insulation deterioration

Search Result 170, Processing Time 0.028 seconds

인공신경망을 이용한 전기배선의 트랙킹 식별에 관한 연구 (Identification of Tracking Conduct Wiring Using Neural Networks)

  • 최태원;이오걸;김이곤
    • 한국지능시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.1-8
    • /
    • 1998
  • In this paper, a method which cna detect tracking caused by the insulation deterioration of conduct wiring, is proposed. To investigate it, we analyzed the harmonics of each load current waveform and those of tracking current waveform with FFT. The computer which take experiment data is learned by neural network algorithm, which has recently been used for the load recognition. The proposed metod in our study can be applied to the development of several measuring equipments such as hotline insulation tester, cna earch tester for the detection of tracking under hot-line state, Furthermore, it can substitutes molded case circuit breaker, fuse, and so on.

  • PDF

배전용 CV케이블의 현장 열화진단 결과의 고찰 (A Study on the Results of the diagnosis of Insulation Deterioration in Live-Line Distribution Power Cables at the Field)

  • 유성종;전승익;정석윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1831-1834
    • /
    • 1996
  • Diagnosis of cable insulation degradation has important meaning from a viewpoint of reliability enhancement of CV cable systems. So, we diagnosed 3.3kV & 6.6kV CV distribution cable on live-line which is judged to a most poor installation condition because they have been used in water condition after installation at the Yeochon chemical complex. The paper describes the analysis of the measured data, the problems at diagnosis, and the items which are considered at the development of diagnosis technology and equipment hearafter.

  • PDF

뇌서지로 인한 피뢰기 열화시 과도상태 분석 (Transient State Analysis in Case of Lightning Arrester Deterioration due to Lightning Surge)

  • 임성용;김규호;이상봉;김수배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.276-277
    • /
    • 2015
  • As the effect of global warming continues, surge rates in Korea are also getting increased. Although there are devices to protect distribution line from the surge like lightning arrester, insulation of the lightning arrester can be destroyed if frequent surge occurs in distribution line. This paper assumed that the lightning surge hits the lightning arrester and make this device's insulation destroyed. This paper also simulated these processes utilizing EMTP/ATPDraw and verified voltage behavior when faults such as line to ground fault due to frequent lightning surge occur in lightning arrester.

  • PDF

저압분전반에서 접지 경로를 통한 차단기의 트래킹 화재위험성에 관한 연구 (A study on the Fire Hazard for the Tracking of RCD through Ground Path at Low Voltage Cabinet Panel)

  • 김동욱;이기연;김동우;길형준;김향곤;정영식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.349-352
    • /
    • 2008
  • The electrical accidents result from insulation blackdown due to over voltage and overheating due to the excess of allowable current, deterioration of insulation performance due to the passage of time, and so on. In this paper, the insulating characteristics of phenolic resin using insulating materials for low voltage were analyzed and the tracking test was performed according to IEC Publ. 112.

  • PDF

대용량 터빈발전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in Large Turbine Generator Stator Windings)

  • 김희동;이영준;박덕현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2093-2096
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in three large turbine generators. Nondestructive tests have been carried out on stand-still generators which have been in service for 2 to 30 years. In most cases these tests include ac current increase rate($\Delta$I), delta tan delta( ${\Delta}tan{\delta}$), and maximum partial discharge(Qm). Gen. 2 show that the $tan{\delta}$ is higher than other two generators in the $tan{\delta}$-voltage curve. Partial discharge(PD) patterns were observed internal, corona and treeing discharges in large turbine generators. The PD tests were confirmed the correlation between discharge patterns and the kinds of defects.

  • PDF

고압전동기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in High Voltage Motor Stator Windings)

  • 김희동;박의갑;박완조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2392-2395
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in six high voltage motors. Nondestructive tests have been carried out on stand-still motors. These tests include ac current increase rate($\Delta$I), delta tan delta(${\Delta}tan{\delta}$), and maximum partial discharge(PD). AC current and $tan{\delta}$ were measured by Schering bridge. The measurement of PD patterns were conducted using digital partial discharge detector. PD patterns were observed treeing and internal discharges in Motor 1 and 2. The stator windings of two motors were found to be in a poor condition and their were recommended to rewind. The stator. windings of four motors were judged to be in serviceable condition.

  • PDF

몰드변압기의 부분방전 검출기술에 관한 연구 (A Study on PD Detection Methods for Cast-resin Dry-type Transformers)

  • 박찬용;박대원;최재성;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제22권9호
    • /
    • pp.786-791
    • /
    • 2009
  • Transformer failures are mostly due to partial discharges (PDs) caused by the deteriorated insulation. It is, therefore, important to monitor PD occurrence in insulation system and prevent their deterioration. The presented paper deals with a PD detection method by a capacitive probe, which easily apply to cast - resin dry - type transformers. The PD detection system consists of a capacitive probe and a low noise amplifier having the frequency bandwidth of 500 $Hz{\sim}30$ MHz. In the experimental set-up, sensitivity of the system is 7.16 mV/pC.

인공지능에 의한 부하전류파형의 인식으로 화재감지 시스템 (Fire detection system by awareness of load current waveform by Neural Network)

  • 이오걸;송호신;김태우;김민회
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.301-304
    • /
    • 2001
  • In this paper, a method which can detect tracking caused by the insulation deterioration of conduct wiring, is proposed. The computer which take experiment data is learned by neural network algorithm, which has recently been used for the load recognition. The proposed method in our study can be applied to the development of several measuring equipments such as hot-line insulation tester, car earth tester for the detection of tracking under hot-line state.

  • PDF

대형발전기 고정자권선 절연재료의 열 사이클에 의한 열화에 관한 연구 (A study on the heat cycle aging of insulation materials in large generator stator windings)

  • 김희곤;박영관
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.553-557
    • /
    • 1996
  • Heat cycle aging of insulating materials in large generator stator winding has been investigated using both on-line and off-line test methods. On this study, principally, off-line test against actual generator in service was carried out to acquire information about polarization index(PI) and dissipation factor, dissipation factor tip-up, maximum partial discharge for the purpose of remnant breakdown voltage and life assessment. It was found from the tests that both dissipation factor and maximum partial discharge decreased with the increase of operating hours and starting numbers. It was found from off-line tests that the remnant breakdown voltage had a strong relationship with both dissipation factor and maximum partial discharge the remnant breakdown voltage as a results of both operating hours and starting number and the nondestructive tests were proposed as parameters which can predict the remnant lifetime of insulating materials in large generator stator windings. (author). 8 refs., 8 figs., 2 tabs.

  • PDF

비접지 선박 3상 배전선로의 대지전압 벡터 모니터링 장치의 구성 (Configuration of a Module for Monitoring Voltages Between Power Lines and Hull Onboard Vessels Based on the Vector Diagram at 3 Phase Ungrounded Power Distribution System)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1111-1116
    • /
    • 2011
  • 비접지방식 선박에서의 접지 고장은 대지 임피던스의 불평형을 가져오고 대지전압을 상승시켜 감전이나 전기화재의 염려가 높아진다. 접지에 따른 이 같은 대지전압의 왜곡 상태는 전기안전의 측면에서 실시간으로 감시할 필요가 있으며 이 경우 대지전압의 측정치를 위상변화 감시가 가능한 벡터다이어그램으로 나타내는 것이 효과적이다. 대지전압의 상태는 중성점 위치에 의해 표시될 수 있다는 점에서 우선 측정된 대지전압 입력에 대해 벡터 평면의 중성점을 출력하는 연산과정과 알고리즘의 해석이 필요하다. 이를 토대로 본 연구에서는 매 샘플링 주기마다 대지전압을 입력하여 컴퓨터 모니터 상에 중성점과 벡터 대지전압을 출력하는 모듈을 구성한 후 실제 배전선로에서의 실험을 통해 제시한 장치의 적정성을 확인하였다.