• Title/Summary/Keyword: insulation characteristic

Search Result 284, Processing Time 0.025 seconds

A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House (한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF

Comparison of vibration and noise characteristic of high efficiency Insulation Panel for Transformer (변압기용 고효율 차음판의 진동 및 소음 비교)

  • Jeong, J.H.;Jang, Y.S.;Lim, D.S.;Kim, J.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.1005-1009
    • /
    • 2008
  • The high efficiency insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in side of city is appeared a lost of problem by increasing to conserve the living environment. Therefor in this paper, first the vibration and noise characteristic of existing insulation panel is analyzed according to attached material, cork and sponge-type. Second the insulation of sound performance is compared between the existing insulation panel. And high efficiency insulation panel that is proposal in this paper.

  • PDF

Insulation Characteristic of Waste Sawdust-mixing Concrete (폐톱밥 혼입 콘크리트의 단열특성에 관한 실험적 연구)

  • Hong, Seung-Ryul;Cho, Byung-Hun;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.98-104
    • /
    • 2005
  • Saw dust concrete f3r finding out insulation characteristic was tested using test plate $30cm{\times}30cm{\times}5cm$. basically, molds f3r the test of compressive, tensile, normal without sawdust, $0.05\%,\;0.1\%,\;0.2\%,\; 0.4\%,\;0.6\%,\;0.8\%,\;1.0\%,\;1.2\%,\;1.4\%,\;1.6\%,\;1.5\%,\;2.0\%$, mixing proportion. heat conductivity of the saw dust concrete mixed with the above proportion was taken in this study. Thermal conduction of normal concrete depends on mixing proportion strength aggregate character, water content. all these items are specified here in fables. $1.8\%\~2.0\%$ saw-dust mising concrete shows as the faction as normal insulation material has its function. and the higher saw-dust mixing rate becomes, the thermal conduction becomes the less Then, the conclusions are that saw-dust using concrete has better insulation function than normal concrete.

A Study on the Electrical Properties for the Insulation Design of a Conduction-Cooled HTS SMES (전도냉각 HTS SMES 절연설계를 위한 전기적 특성연구)

  • Choi, Jae-Hyeong;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Baek, Seung-Myeong;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.226-227
    • /
    • 2006
  • The conduction-cooled HTS SMES is operated in cryogenic and high vacuum condition. Thus, Insulation design at cryogenic temperature and high vacuum is a key and an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. Therefore, we need active research and development of insulation concerning application of the conduction-cooled HTS SMES. Therefore, in this study, we experimented about insulation characteristic high vacuum and cryogenic similar to driving condition of SMES system. Also, investigated about insulation characteristic of suitable some materials to insulator for conduction-cooled HTS SMES. As this results, we possessed basis data for insulation materials selection and insulation design for development of 600 kJ class conduction-cooled HTS SMES.

  • PDF

Gas detection of transformer oil according to degradation characteristic of insulation material (절연물의열화에 의한 변압기유의 가스분석)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Lee, Suck-Woo;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.574-574
    • /
    • 2005
  • To found out the degradation characteristic of transformer insulation, insulation material was depisited into transformer oil and heated. Due to the thermal stress which added to insulation, the density of carbon dioxide which included in transformer oil was mesured by using the gas density detection equipment of gas sensor and air circulation method. As a result, it didn't match with the transformer supervision standard. But it was found that as thermal stress increased, the density of carbon dioxide propertionally increased.

  • PDF

A Study on the Electrical Properties of the Conduction-cooled HTS SMES System (전도냉각형 고온초전도 에너지저장장치의 전기적 특성)

  • Choi, Jae-Hyeong;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Hae-Jong;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.2
    • /
    • pp.135-141
    • /
    • 2007
  • The conduction-cooled HTS SMES is operated in cryogenic and high vacuum condition. Thus, Insulation design at cryogenic temperature and high vacuum is a key and an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in vacuum are virtually unknown. Therefore, we need active research and development of insulation concerning application of the conduction-cooled HTS SMES. Therefore, in this study, we experimented about insulation characteristic high vacuum and cryogenic similar to driving condition of SMES system. Also, investigated about insulation characteristic of suitable some materials to insulator for conduction-cooled HTS SMES. As this results, we possessed basis data for insulation materials selection and insulation design for development of 600 kJ class conduction-cooled HTS SMES.

Analysis of Insulation Characteristic for Small Hydro Generator (소수력발전기 절연특성분석)

  • Oh, Bong-Keun;Chang, Jeong-Ho;Lee, Kwang-Ho;Kang, Dong-Sik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.142-145
    • /
    • 2008
  • Electrical insulation of small hydro generator stator winding is one of the most important parts in generator facilities. Some stator winding insulation problems can be identified through analysis of insulation diagnostic test. So, Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of small hydro generator. This paper presents case studies of insulation failure in generator stator windings and the results of insulation diagnostic test for small hydro generator stator windings. Especially, Conducting the insulation diagnostic test before the generator installed in site is very important process to keep the good insulation condition in service.

  • PDF

A Study on Insulation Performance Enhancement of Existing Transmission Line Considering Overvoltage Analysis Result and Fault Characteristic (과전압 분석 결과와 고장특성을 고려한 기설 송전선로의 절연보강 방법에 관한 연구)

  • Kwak, Joo-Sik;Woo, Jung-Woog;Koo, Kyo-Sun;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.162-168
    • /
    • 2009
  • This paper describes a study that is to redesign insulation of transmission lines and determine required the numbers of insulators in order to enhance the insulation performance of existing transmission lines which were constructed with standard insulation design, considering overvoltage analysis results, probabilities and characteristics of faults. To ensure proper insulation distance without deteriorating the required performance, EMTP model is established to calculate maximum overvoltage in the line. The fault records and predicted outage rates due to lightning and contamination in the line were investigated and analyzed respectively. It presents a method to determine the numbers of insulators considering the probability and the characteristic of fault.

A study of the Insulation Characteristic in $SF_6-N_2$ Mixture Gases ($SF_6-N_2$ 혼합기체의 절연특성에 관한 연구)

  • Ha, Sung-Chul;Song, Byoung-Doo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.613-616
    • /
    • 2001
  • This SF6 gas is widely used in industrial of insulation field. In this paper, N2 is mixed to improve pure SF6 gas characteristics. Electron transport coefficients in SF6-N2 mixture gases are simulated in range of E/N values from 70 to 400 [Td] at 300K and 1 Torr by using Boltzmann equation method. The results of this method, which are like electron drift velocity, ionization coefficient, attachment coefficient, effective ionization coefficient, and critical EIN, can be important data to present characteristic of gas for insulation. Specially critical E/N is a data to evaluate insulation strength of a gas and is presented in this paper for various mixture ratios of SF6-N2 mixture gases.?⨀␍?܀㘱〮㜳㬓M敤楣楮攠慮搠桥污瑨

  • PDF

Analysis of EMF Mitigation Characteristic for Transmission Tower Using Compact Insulation Arm (Compact 절연암 송전 철탑의 전자계 저감특성 분석)

  • Song, Hong-Jun;Lee, Won-Kyo;Lee, Sang-Yun;Choi, In-Hyeok;Lee, Dong-Il;Byeon, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.349-355
    • /
    • 2009
  • As electrical power demand is gradually increasing, the construction of power transmission facility is unavoidable. However difficulties which resulted from increasing of complaints and NYMBY make power transmission tower to be more environmentally friendly. As an alternative proposal, a new method which is changing conventional iron arm for insulation arm which is made of FRP(Fiber Glass Reinforced Plastics) is in progress. In this paper, we discussed environmentally friendly characteristic of domestic 154 kV testing transmission tower whose insulation arms have same mechanical and excellent electrical properties compare to conventional heavy iron arm.