• 제목/요약/키워드: insulating performance

검색결과 240건 처리시간 0.03초

옥외용 고분자 절연재료의 자외선 열화특성 연구 (A Study on the Ultraviolet Aging characteristics of Outdoor Polymeric Insulating Materials)

  • 김영성;이상진;박완기;정순욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1404-1406
    • /
    • 1998
  • The outdoor polymeric insulating materials such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged by various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-ray on surface of silicone rubber were investigated by using the weather-Ometer. The accelerated aging stresses were simulated by UV radiation. high temperature and humidity as well as water spray. These the aging characteristics were examined through contact angle measurements, tracking resistance test, FT-IR and SEM/EDS analysis. the experimental results showed that tracking resistance decreases with increase in the UV-ray irradiation period. But the surface of silicone rubber kept hydrophobicity. It is found that the inorganic filler such as $Al(OH)_3$ improves tracking resistance and the $TiO_2$ is very effective in preventing degradation of silicone rubber surface from UV-ray.

  • PDF

저압분전반에서 접지 경로를 통한 차단기의 트래킹 화재위험성에 관한 연구 (A study on the Fire Hazard for the Tracking of RCD through Ground Path at Low Voltage Cabinet Panel)

  • 김동욱;이기연;김동우;길형준;김향곤;정영식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.349-352
    • /
    • 2008
  • The electrical accidents result from insulation blackdown due to over voltage and overheating due to the excess of allowable current, deterioration of insulation performance due to the passage of time, and so on. In this paper, the insulating characteristics of phenolic resin using insulating materials for low voltage were analyzed and the tracking test was performed according to IEC Publ. 112.

  • PDF

광섬유센서를 이용한 유중방전 신호검출 (Discharge Signal Detection in Insulating Oil using Optical Fiber sensor)

  • 이준호;이종길;김상준;남진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2066-2068
    • /
    • 1999
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Sagnac interferometer was proposed to detect the discharge signals which generated from needle-sphere electrode system in insulating oil. The performance of OF sensor was checked by sinusoidal calibration signal generated by PZT acuator at 198kHz. The detected discharge signals consisted of acoustic signal and the electrical noise. The noise signal could be removed by digital low pass filter. It was demonstrated that the OF sensor in this research had a possibility to detect the discharge signals in power apparatus.

  • PDF

고방열 절연시트의 기술개발 동향 (Review of Technology Development of High Heat Dissipative Insulating Sheet)

  • 유명재;박성대;임호선;이우성
    • 마이크로전자및패키징학회지
    • /
    • 제19권1호
    • /
    • pp.9-16
    • /
    • 2012
  • Currently due to increasing integration of various electronic devices and need of multi-functions, more and more heat is produced and for electronic devices to achieve maximum performance with optimum life time, heat dissipation is critical. A solution to such problems is use of high heat dissipative insulating sheet. In this paper status of current products are introduced and several technology aspects to meet the demand of increased heat dissipation needs is introduced.

광섬유 Sagnac 간섭계를 이용한 유중방전 신호검출 (Discharge Signal Detection in Insulating Oil using the Optial Fiber Sagnac Interferometer)

  • 이종길;이준호;김상준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권11호
    • /
    • pp.622-626
    • /
    • 2000
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Sagnac interferometer was proposed to detect the discharge signals. The needle-sphere electrode system in insulating oil generated the signals. The performance of OF sensor was checked by sinusoidal calibration signal generated by PZT actuator at 198KHz. The detected discharge signals consisted of acoustic signal and the electrical noise. The noise signal could be removed by digital low pass filter. It was demonstrated that the OF sensor in this research had a possibility to detect the discharge signals in power apparatus.

  • PDF

식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구 (A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer)

  • 정중일;허창수
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

변압기 절연유중 수소 가스의 검지 시스템 설계 (Developement of Gas Detector Dissolved In Transfomer Oil)

  • 황규현;서호준;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.207-210
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will make insulating material(oil, kraft paper, proclain and wood) be stressed and generate many sort of gases($CO,\;CO_2,\;H_2,\;C_2H_4$) which are dissolved in transformer oil. The ratio of this gas can make diagnostic tecchniques of the lifetime of transfomer so, it is important to monitoring $H_2$ gas continuously. This paper developes a system of detecting about $H_2$ gas by using $H_2$ gas sensor, and we describe operation and performance of this system

  • PDF

다층형 단열재를 사용한 영구거푸집의 처짐 특성 (Deflection Characteristics of Permanent Formwork Using Multi-layer Insulation)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.130-131
    • /
    • 2019
  • As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. In addition, the conventional styrofoam insulating material has a problem that the thickness of the heat insulating material to achieve a standard heat permeability is rapidly increased. Due to the thick insulation, there is a high risk of spreading vulnerable structures such as fire due to lack of space between buildings. On the other hand, the method of using the insulation as a formwork is known to be excellent cost saving effect through the reduction of the formwork usage and the simplification of the external insulation work. In order to solve this problem, this study aims to fabricate a multi-layered insulator that combines high-performance phenolic foam insulation and styrofoam insulation and evaluate the deflection characteristics for use as formwork.

  • PDF

고온초전도 케이블의 응용을 위한 PPLP의 절연파괴 특성연구 (Study on the Breakdown Performance of Synthetic Polypropylene Laminated Paper for Application of a HTS Cable)

  • 곽동순;김영석;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.65-68
    • /
    • 2003
  • In this paper, we researched breakdown characteristics of paper/liquid nitrogen composite insulation system for application of a high temperature superconducting cable. And, we have studied the AC breakdown performance of paper/ice composite insulating system immersed in liquid nitrogen. The electric strength in this paper/ice composite system is higher than that of paper/liquid nitrogen system. Furthermore this system shows a self-healing type breakdown behavior. Among the many kinds of liquid to be immersed and frozen to the ice, deionized water gives the highest electric breakdown strength. The paper/ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

Quantitative Immunoassay for Polychlorinated Biphenyl Compounds in Electrical Insulating Oils

  • Kim In Soo
    • 한국미생물학회:학술대회논문집
    • /
    • 한국미생물학회 2000년도 추계학술발표대회
    • /
    • pp.119-127
    • /
    • 2000
  • The development and performance of a competitive indirect immunoassay for the quantitative measurement of polychlorinated biphenyl compounds in insulating oils is presented. Reagent preparation and the assay characterisation, optimisation and validation steps are described. The dynamic range of the assay for Aroclors 1254 and 1260 in methanol was $50-800 {\mu}g\;ml^{-1}$ with $50\%$ signal inhibition values of 217 and $ 212 {\mu}g\;ml^{-1}$ respectively. Impending legislation in the UK is likely to decree that oils containing $ >50 {\mu}g\;ml^{-1}$ PCB be considered contaminated. Assay sensitivity increased with the degree of PCB chlorination. The assay of structurally related compounds of environmental concern yielded cross-reactivity values of under $0.6\%$. The immunoassay proved reliable for the analysis of transformer oils containing $>70{\mu}g\;ml^{-1}$ PCB, but over-estimated PCB levels in oils containing $<20{\mu}g\;ml^{-1}$ of the analyte with the oils requiring pre-treatment using either solid-phase extraction techniques or washing with KOH-ethanol/sulphuric acid to remove matrix interferents. The analytical performance of the assay was compared against a commercially available semi-quantitative immunoassay kit for PCBs in soil and water.

  • PDF