• 제목/요약/키워드: insulating paper

검색결과 490건 처리시간 0.04초

가속 열 열화에 따른 환경친화형 변압기 절연물의 전기적-기계적 특성 분석 (Analyses on Electrical-Mechanical Characteristics of Environment-friendly Transformer Insulating Material by Accelerated Thermal Aging)

  • 심명섭;안정식;최순호;정중일;이태호;허창수
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1832-1838
    • /
    • 2010
  • Aging of transformer insulating material in natural ester insulating oil is compared to that in conventional transformer oil. Aging of insulating paper and insulating oil have been studied by performing accelerated thermal aging test. Sealed aging test vessels containing cooper, laminated core, Kraft paper and insulating oil(natural oil or mineral oil) were aged at $140^{\circ}C$ for 500, 1000, 1500 and 2000 hours. Insulating oils after aging are investigated with total acid number, breakdown voltage and viscosity. Also, degradation of insulating paper after aging is determined using breakdown voltage and mechanical strength. Accelerated aging studies demonstrate a slower aging rate for natural ester insulating oil compared to the rate for conventional mineral oil.

UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정 (Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제35권3호
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

경계요소법을 이용한 표면 거침도에 따른 아라미드 절연지의 전계분포 해석 (Analysis of Electric Field Distribution according to Surface Roughness of Aramid Insulating Paper Using Boundary Element Method)

  • 김탁용;안병철;조경순;박형준;홍진웅
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.34-39
    • /
    • 2006
  • In this paper, we investigated the electric field distribution according to the roughness in aramid insulating paper for electric machine. Aramid insulating paper has been used to electric insulating of the traction motor and generators for large capacity. We studied the electric field distribution using boundary element method for Aramid insulating paper. As a result of simulation, the electric field increased according to the surface roughness existence. Electric field decreased due to radius of surface roughness reduction, and Electric field concentration appeared at electrode boundary and rough surface.

절연지에 의한 전력용변압기 열화진단 기술 (Diagnostic techniques of aging deterioration of power transformer by insulating paper)

  • 박현주;남창현;윤여찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.449-452
    • /
    • 2004
  • The life of power transformer is basically dependent on the aging deterioration of insulating paper. Analysis of insulating paper for its DP value or tensile strength requires removal of a few strips of paper but direct measurement of this properties is not practical for in-service transformers. For this reason furfural analysis by HPLC has gained increasing favor as a means of estimating degradation of insulating papers in power transformers and this paper reports on the analysis of data on the concentration of furfural in oil samples from about 50 power transformers and the case study. The data showed that furfural content can estimate more accurately aging characteristics compared to concentration of CO, $CO_2$. We expect that these results can be useful to predict the aging characteristics and life diagnosis of power transformers and further the study must be continued.

  • PDF

주상변압기용 절연지의 가속화 후 전기적 특성 (Electrical Characteristics of Insulating Paper for Pole Transformers after Accelerated Ageing)

  • 송일근;정종욱;이병성;한용희;김찬영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1591-1593
    • /
    • 2001
  • In this paper, the electrical characteristics of Insulating paper, for pole transformers, subjected to accelerated ageing were observed and the results were compared with those of virgin insulating paper. For the experiment, insulating materials for pole transformers were enclosed together in an oil bath and thermally aged under the real pole transformer operating conditions. After the accelerated ageing of the insulating materials, the dielectrics were measured and compared with the results of the virgin ones.

  • PDF

특고압 변압기 건전성 평가에 관한 연구 (A Study on the integrity assessment of the high voltage transformer with Dissolved Gas Analysis)

  • 이일무;유상봉;정해성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1463-1464
    • /
    • 2015
  • This paper describes for the diagnosis insulating oil for transformers integrity assessment. The high-capacity oil transformer has several insulators are entered for the purpose of insulation, such as insulating oil, insulating paper and press board. Irradiated with a gas component dissolved in the insulating oil can analyze the status of the transformer, and can prevent a sudden accident in advance.

  • PDF

셀룰로오스 절연지의 열화온도에 따른 절연특성 및 통계처리에 의한 상관관계 규명 (Estimating for Properties of Insulating Degradation for Cellulose paper with Aging Temperature and Correlation by Statistical Treatment)

  • 김재훈;김대식;한상옥
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.912-917
    • /
    • 2010
  • It was known that oil-filled transformer's life depended on insulating paper which was applied to transformers for insulating of transformer. Therefore when paper was aged, its electrical, mechanical and chemical characteristics were changed. Especially if operating temperature was high, paper was quickly damaged. As cellulose paper which was mainly used for solid insulation of transformers was degraded, the cellulose polymer chains broke down into shorter lengths and gases such as CO, $CO_2$, $CH_4$, $C_2H_4$ and so on were produced from paper. Also by-product known as furan compounds were producted from paper and it were dissolved within insulating oil. In this paper accelerating aging cell was aged during 60 hours at 100, 150, 180 and $200^{\circ}C$, respectively, so evaluating the chemical characteristics of cellulose paper by thermal. An it were performed analysis such as tensile strength(TS), dissolved gas analysis(DGA) and high performance liquid chromatography(HPLC). Also for analyzing of correlation between insulating degradation characteristics, it was performed linear regression method as statistical treatment.

친환경 식물성절연유의 유동대전현상 연구 (Research of Flow Electrification Phenomena of the used Environment-Friendly Vegetable Insulating Oils)

  • 최순호;허창수
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.580-584
    • /
    • 2012
  • The insulating oils perform a cooling and insulation action in electric power transformer. The mineral oil has immanent fire dangerousness and environmental contamination problem. Vegetable insulating oil has higher ignition point, flash point and more excellent biodegradability than conventional mineral oil. In a real oil-filled transformers, some of the power is dissipated in the form of heat. And transformer require the heat to be removed from the winding and insulator by forced convection of the insulating oil. The flow electrification occurs when insulating oil was forced to be circulated. In this paper, influence of temperature, velocity of flow, and insulating pipe and diameter on streaming electrification of vegetable insulating oil was investigated using forced circulation apparatus. Temperature effects were most significant, and it showed a peak in the temperature $30^{\circ}C$ to $35^{\circ}C$ at insulating and copper pipe. The change of flow electrification according to area variety could be checked by change of diameter.

표면 거침도에 따른 종이절연지의 전계분포 (Electric field distribution according to surface roughness of insulating paper)

  • 박형준;김원종;신종열;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.323-326
    • /
    • 2004
  • The this paper is describing about the electric field distribution due to the roughness in Aramid insulating paper for electric machine. The insulting and pressboard paper have been used at electric insulating of traction motor and generators. There was a change investigation of the electric field distribution according to the roughness of specimen by simulation program of Electro. We studied the electric field distribution using boundary element method for Aramid insulator. We find out an optimal condition in insulating paper of electric machine.

  • PDF

변압기절연재료의 유동대전특성에 미치는 제인자 연구 (A STUDY ON THE FACTOR OF STATIC ELECTRIFICATION ON TRANSFORMER INSULATING-MATERIALS)

  • 이숭녕;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1143-1145
    • /
    • 1995
  • In this paper, we measured leakage current that produced by static electrification at pressboard and insulating paper. We found that the leakage current increased as temperature increased, as oil velocity increased. The leakage current at pressboard is higher than that of insulating paper.

  • PDF