Journal of the Korean Society for Aeronautical & Space Sciences
/
v.33
no.2
/
pp.113-118
/
2005
This paper shows a satellite battery cell voltage monitor system to make differential voltage measurements when one or both measurement points are beyond voltage range allowed by a conventional differential amplifier. This system is particularly useful for monitoring the individual cell voltage of series-connected cells that constitute a rechargeable satellite battery in which some cell voltages must be measured in the presence of high common mode voltage.
In precision instrumentation system, an A/D conversion of signal conditioning has been always suffered from some problems ; offset and drift voltage with environmental situation. This paper suggests a method of reducing the offset voltage and the drift error from the A/D conversion hardware using analog signal switching technique with specific operational amplifier circuits. Also, we have designed a hardware active filter and a software digital filter with Auto Zero Tracking algorithm for better dignal process of the our proposed weighing system. Software technique was performed to obtain the stable data from A/D converter. As a result of our experimental works, the proposed system is expected to be used in the industrial field where a high precision measurement is required.
Journal of the Korean Society of Manufacturing Process Engineers
/
v.21
no.4
/
pp.31-38
/
2022
In this study, we designed and manufactured an intelligent gripper-control device to safely grip unknown objects. The gripper control device consists of a DSP circuit, power supply circuit, communication circuit, and amplifier circuit diagrams. The DSP is used because the values of the 3-axis force sensor to which the gripper is attached are measured and calculated at high speeds. The gripping force is determined based on this value, and the object must be safely gripped with the determined value. A basic characteristic test of the control device of the manufactured intelligent gripper was conducted, and it was confirmed that it operated safely.
An instrumentation system to measure the pressure between elastic bodies and between an elastic and a rigid body has been developed. The force between elastic bodies can be measured only by Elastric- body pressure Meter. As a standard Elastic-body pressure Meter, Model RCG-24A consists of 24 pick-ups, one switch box and one amplifier and measuring is possible at each of 24 measuring spots by swithing one to the nest using the switch box. The system can be used in various specialized disciplines, such as ergonomics, anthropometry and biomechanics.
Journal of the Korea Institute of Information and Communication Engineering
/
v.20
no.7
/
pp.1303-1310
/
2016
In this paper, electrocardiogram (ECG) analog front end with supply voltage of 0.5V has been designed and verified by measurements of fabricated chip. ECG is composed of instrument amplifier, 6th order gm-C low pass filter and variable gain amplifier. The instrument amplifier is designed to have gain of 34.8dB and the 6th order gm-C low pass filter is designed to obtain the cutoff frequency of 400Hz. The operational transconductance amplifier of the low pass filter utilizes body-driven differential input stage for low voltage operation. The variable gain amplifier is designed to have gain of 6.1~26.4dB. The electrocardiogram analog front end are fabricated in TSMC $0.18{\mu}m$ CMOS process with chip size of $858{\mu}m{\times}580{\mu}m$. Measurements of the fabricated chip is done not to saturate the gain of ECG by changing the external resistor and measured gain of 28.7dB and cutoff frequency of 0.5 - 630Hz are obtained using the supply voltage of 0.5V.
Joint pain is generally a common disorder not only for the old aged people but also for the immunocompromised patients. The present proposed study reveals the presence of inflammatory diseases in joint generally diagnosed by removing synovial fluid and changes in the volume and composition are examined for the presence of WBC and crystals. This study implement a non-invasive approach to identify the changes in joint fluid by measuring the changes in electrical property of the synovial tissue under the influence of electrical current signal with frequency range between 100 kHz to 300 kHz. The response of tissue for the current signal was measured in terms of potential drop across the tissue. The hardware system design consists of input and output sections. The input section which applies current signal to upper limb joint region is made of ICL8038 function generator IC with amplifier and voltage to current converter. The output section picks voltage variation using metal surface electrode, amplifier, ADC, PIC microcontroller and LCD interface. 100 patient inclusive of normal and disease affected patients where examined for upper limb synovial fluid variation and inflammatory diseases were identified.
Lee, Sang-Kyung;Lee, Jun-Yeong;Choi, Yun-Seok;Park, Hong Bea
IEMEK Journal of Embedded Systems and Applications
/
v.8
no.3
/
pp.129-136
/
2013
In this paper, a motion control system based on 2-axis gimbal system is designed and implemented to drive a high speed and precision. The proposed system consists of the RS-422 interface, 2-axis gimbal platform, servo control unit integrated with a high speed DSP chip-set, servo amplifier unit, potentiometer sensor unit, and resolver sensor unit. The servo control unit using the high speed DSP firmware is designed to get a fast response without an overshoot with step input and a RMS error of low probability with ramp input. The servo amplifier unit using a voltage control is designed to resolve the zero-crossing distortion for precise motion. To verify the performance and stability of the implemented system, experiments are performed through a measurement of the time and frequency domain response in a laboratory environment by using a PXI(PCI eXtentions for Instrumentation).
Kim, Dong-Jun;Lee, Hyun-Min;Woo, Seung-Jin;Lee, Ju-Shin;Lee, Jeong-Whan;Kim, Kyeong-seop
The Journal of Korea Institute of Information, Electronics, and Communication Technology
/
v.1
no.3
/
pp.41-47
/
2008
This paper describes a wearable electro-stethoscope module for home-healthcare system. The module is consisted of a microphone, an instrumentation amplifier, a filter, a power amplifier etc. and is light and small. The phonogram signal from the module shows good performance. The test for the material and size of the sound collector of the chest piece is performed and the results is reflected on the prototype product. If the module is connected to wired or wireless communication network, so people can check their health without going hospital.
This paper presents a development of interface device for electro-oculogram(EOG) signal and it's application to the wireless mouse of wearable PC. The interface device is composed of five bio-electrodes for detecting oculomotor motion, several band-pass filters, instrumentation amplifier and a microprocessor. we have first analyzed impedance characteristics between skin and a bio-electrode. since the impedance highly depends on human face, it's magnitude differs from person. this interface device was applied to develop a wireless mouse for wearable PC, as a Bio Machine Interface(BMI). Where in the prompt on PC monitor is controlled by only EOG signals. this system was implemented in a Head Mount Display(HMD) unit. experimental results show the accuracy of above 90%.
This paper introduces the design of BiCMOS latched comparator circuit for high-speed system application, which can be used in data conversion, instrumentation, communication system etc. By exploiting the advantage technology of the combination of both the bipolar transistor and the CMOS transistor devices. The comparator circuit includes an input stage that combines MOS sampling with a bipolar regenerative amplifier. The resistive load of conventional current-steering comparator is replaced by a load, which is made by a NMOS transistor. The advantage of design and PSPICE simulation of BiCMOS latched comparator are the circuit will obtain wide bandwidth with lowest power consumption at a single supply voltage. All the characteristics of the proposed BiCMOS latched comparator circuit is carried out by simulation program.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.