• Title/Summary/Keyword: instrumentation%3A CCD camera

Search Result 6, Processing Time 0.022 seconds

CHARACTERISTICS AND PERFORMANCE OF A FAST CCD CAMERA: DALSTA IM30P

  • SEO YOUNG-MIN;PARK KI-WOONG;CHAE JONGCRUL
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.185-191
    • /
    • 2004
  • We have been developing a solar observing system based on a fast CCD camera 1M30P made by the DALSA company. Here we examine and present the characteristics and performance of the camera. For this we have analyzed a number of images of a flat wall illuminated by a constant light source. As a result we found that in the default operating mode 1) the mean bias level is 49 ADU/pix, 2) the mean dark current is about 8 ADU /s/pix, 3) the readout noise is 1.3 ADU, and 4) the gain is about 42 electrons/ ADU. The CCD detector is found to have a linearity with a deviation smaller than $6\%$, and a uniform sensitivity better than $1\%$. These parameters will be used as basic inputs in the analysis of data to be taken by the camera.

LABORATORY TEST OF CCD #1 IN BOAO (보현산 천문대 1번 CCD카메라의 실험실 테스트)

  • Park, Byeong-Gon;Cheon, Mu-Yeong;Kim, Seung-Ri
    • Publications of The Korean Astronomical Society
    • /
    • v.10 no.1
    • /
    • pp.67-78
    • /
    • 1995
  • An introduction to the first CCD camera system in Bohyunsan Optica1 Astronomy Observatory(CCD#l) is presented. The CCD camera adopts modular dewar design of IfA(Institute for Astronomy at Hawaii University) and SDSU(San Diego State University) general purpose CCD controller. The user interface is based on IfA design of easy-to-use QUI program running on the NeXT workstation. The characteristics of the CCD#l including Gain, Charge Transfer Efficiency, rms Read-Out Noise, Linearity and Dynamic range is tested and discussed. The CCD#l shows 6.4 electrons RON and gain of 3.49 electrons per ADU, and the optimization resulted in about 27 seconds readout time guaranteeing charge transfer efficiency of 0.99999 for both direction. Linearity test shows that non-linear coefficient is $6{\times}10^{-7}$ in the range of 0 to 30,000 ADU.

  • PDF

SEOUL NATIONAL UNIVERSITY CAMERA II (SNUCAM-II): THE NEW SED CAMERA FOR THE LEE SANG GAK TELESCOPE (LSGT)

  • Choi, Changsu;Im, Myungshin
    • Journal of The Korean Astronomical Society
    • /
    • v.50 no.3
    • /
    • pp.71-78
    • /
    • 2017
  • We present the characteristics and the performance of the new CCD camera system, SNUCAM-II (Seoul National University CAMera system II) that was installed on the Lee Sang Gak Telescope (LSGT) at the Siding Spring Observatory in 2016. SNUCAM-II consists of a deep depletion chip covering a wide wavelength from $0.3{\mu}m$ to $1.1{\mu}m$ with high sensitivity (QE at > 80% over 0.4 to $0.9{\mu}m$). It is equipped with the SDSS ugriz filters and 13 medium band width (50 nm) filters, enabling us to study spectral energy distributions (SEDs) of diverse objects from extragalactic sources to solar system objects. On LSGT, SNUCAM-II offers $15.7{\times}15.7$ arcmin field-of-view (FOV) at a pixel scale of 0.92 arcsec and a limiting magnitude of g = 19.91 AB mag and z=18.20 AB mag at $5{\sigma}$ with 180 sec exposure time for point source detection.

A NEW AUTO-GUIDING SYSTEM FOR CQUEAN

  • CHOI, NAHYUN;PARK, WON-KEE;LEE, HYE-IN;JI, TAE-GEUN;JEON, YISEUL;IM, MYUNGSHI;PAK, SOOJONG
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.3
    • /
    • pp.177-185
    • /
    • 2015
  • We develop a new auto-guiding system for the Camera for QUasars in the EArly uNiverse (CQUEAN). CQUEAN is an optical CCD camera system attached to the 2.1-m Otto-Struve Telescope (OST) at McDonald Observatory, USA. The new auto-guiding system differs from the original one in the following: instead of the cassegrain focus of the OST, it is attached to the finder scope; it has its own filter system for observation of bright targets; and it is controlled with the CQUEAN Auto-guiding Package, a newly developed auto-guiding program. Finder scope commands a very wide field of view at the expense of poorer light gathering power than that of the OST. Based on the star count data and the limiting magnitude of the system, we estimate there are more than 5.9 observable stars with a single FOV using the new auto-guiding CCD camera. An adapter is made to attach the system to the finder scope. The new auto-guiding system successfully guided the OST to obtain science data with CQUEAN during the test run in 2014 February. The FWHM and ellipticity distributions of stellar profiles on CQUEAN, images guided with the new auto-guiding system, indicate similar guiding capabilities with the original auto-guiding system but with slightly poorer guiding performance at longer exposures, as indicated by the position angle distribution. We conclude that the new auto-guiding system has overall similar guiding performance to the original system. The new auto-guiding system will be used for the second generation CQUEAN, but it can be used for other cassegrain instruments of the OST.

SEOUL NATIONAL UNIVERSITY 4K×4K CAMERA (SNUCAM) FOR MAIDANAK OBSERVATORY

  • Im, Myung-Shin;Ko, Jong-Wan;Cho, Yun-Seok;Choi, Chang-Su;Jeon, Yi-Seul;Lee, In-Duk;Ibrahimov, Mansur
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.3
    • /
    • pp.75-93
    • /
    • 2010
  • We present the characteristics of the Seoul National University 4k Camera (SNUCAM) and report its performance on the 1.5m telescope at the Maidanak observatory in Uzbekistan. SNUCAM is a CCD camera with a pixel scale of 0.266" in $4096{\times}4096$ format, covering $18.1'{\times}18.1'$ field of view on the 1.5m. The camera is currently equipped with Bessell UBVRI, $H{\alpha}$, SDSS ugriz, and Y-band filters, allowing us to carry out a variety of scientific programs ranging from exoplanet studies to survey of quasars at high redshift. We examine properties of SNUCAM such as the bias level and its temporal variation, the dark current, the readout noise, the gain, the linearity, the fringe patterns, the amplifier bias, and the bad pixels. From our observations, we also constructed the master fringe frames in I-, z-, and Y-band. We outline some of the current scientific programs being carried out with SNUCAM, and demonstrate that SNUCAM on the 1.5m can deliver excellent images that reach to the $5-{\sigma}$ detection limits of R~25.5 mag and z~22.7 mag in 1 hour total integration.

EFFECT OF ANTICURVATURE FILING METHOD ON PREPARATION OF THE CURVED ROOT CANAL USING PROFILE (PROFILE을 이용한 근관형성 시 ANTICURVATURE FILING방법의 영향)

  • Song, Hyun-Ji;Chang, Ju-Hea;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.327-334
    • /
    • 2005
  • This study investigated the effect of anticurvature filing method on preparation of the curved root canal using ProFile. Thirty six resin blocks were divided equally into three groups by instrumentation motions: anticurvature filing motion. circumferential filing motion and straight up-and-down motion. Each resin block was sectioned at 8mm level from the apex and at the greatest curvature of the canal and reassembled in metal mold by a modified Bramante technique. All groups were instrumented with the ProFile system. At each levels. image of sectioned surface were taken using CCD camera under a stereomicroscope at $\times40$ magnification and stored. Distances of transportation at the inner and outer area of curvature and the centering ratio were determined and compared by statistical analysis. along with the assessment of the increase of root canal cross-sectional area. The results were as follows; 1. In all groups. there was no statistical difference in the mean increase of root canal cross-sectional area. the centering ratio. and the mean distances of transportation at the inner area of curvature at each level. 2. At 8mm level from the apex. the mean distances of transportation at the outer area of curvature decreases in following order anticurvature filing motion. circumferential filing motion. straight up-and­down motion but. no significant difference at the greatest curvature of the canal among three groups. Effect of anticurvature filing motion using ProFile does not seem to be different from other instrumentation motions at the inner area of curvature in curved root canal.