• Title/Summary/Keyword: instrument design

Search Result 884, Processing Time 0.027 seconds

Family of the Sun-and-Stars Time-Determining Instruments (Ilseong-jeongsi-ui) Invented During the Joseon Dynasty

  • Lee, Yong Sam;Kim, Sang Hyuk;Mihn, Byeong-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.237-246
    • /
    • 2016
  • We analyze the design and specifications of the Sun-and-Stars Time-Determining group of instruments (Ilseong-jeongsi-ui, 日星定時儀) made during the Joseon dynasty. According to the records of the Sejong Sillok (Veritable Records of King Sejong), Sun-and-Stars Time-Determining Instruments measure the solar time of day and the sidereal time of night through three rings and an alidade. One such instrument, the Simplified Time-Determining Instrument (So-jeongsi-ui, 小定時儀), is made without the essential component for alignment with the celestial north pole. Among this group of instruments, only two bronze Hundred-Interval-Ring Sundials (Baekgak-hwan-Ilgu, 百刻環日晷) currently exist. A comparison of the functions of these two relics with two Time-Determining Instruments suggests that the Hundred-Interval-Ring Sundial is a Simplified Sundial (So-ilyeong, 小日影), as recorded in the Sejong Sillok and the Seongjong Sillok (Veritable Records of King Seongjong). Furthermore, the Simplified Sundial is a model derived from the Simplified Time-Determining Instrument. During the King Sejong reign, the Sun-and-Stars Time-Determining Instruments were used in military camps of the kingdom's frontiers, in royal ancestral rituals, and in royal astronomical observatories.

Monte Carlo shielding evaluation of a CSNS Multi-Physics instrument

  • Liang, Tairan;Shen, Fei;Yin, Wen;Xu, Juping;Yu, Quanzhi;Liang, Tianjiao
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1998-2004
    • /
    • 2019
  • The Multi-Physics (MP) instrument is one of 20 neutron spectrometers planned in the China Spallation Neutron Source (CSNS). This paper presents a shielding calculation for the MP instrument using Monte Carlo codes MCNPX and FLUKA. First, the neutrons that escape from the CSNS decoupled water moderator and are delivered to the beam line of the MP instrument are calculated to use as the source term of the shielding calculation. Then, to validate the calculation method based on multiple variance reduction techniques, a cross check between MCNPX and FLUKA codes is performed by comparing the calculation results of the dose rate distribution on a simplified beam line model. Finally, a complete geometry model of the MP instrument is set up, and the primary parameters for the shielding design are obtained according to the calculated dose rate map considering different worst-case scenarios.

Validity and Reliability of the Korean Version of the Observable Indicators of Nursing Home Care Quality Evaluation Instrument (한국형 노인요양시설 질 관찰평가도구의 타당도와 신뢰도 분석)

  • Lee, Ji-A
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.3
    • /
    • pp.474-482
    • /
    • 2008
  • Purpose: The purposes of this study were; 1) to test the validity and reliability of the Korean version of Rantz's Observable Indicators of Nursing Home Care Quality Instrument (ONHQ) and 2) to evaluate the quality of Korean nursing homes. Methods: The study employed a three-phase methodological research design. 1) The original instrument of Rantz's. ONHQ was translated into Korean and modified by Korean nursing home experts. 2) A pilot study using the modified instrument was done in 20 nursing homes to examine inter-rater reliability. 3) The validity and reliability were tested.in 98 nursing homes. Results: Seven factors were extracted through factor analysis: 'communication', 'care delivery', 'grooming', 'odor, 'environment-basics', 'environment-access', and 'environment-homelike'. These factors explained 86.07% of the total variance. Cronbach's alpha coefficient of the 30 items was .97 indicating a high internal consistency of the instrument. Inter-rater reliability according to Kappa was .82. The average score of nursing home quality was 112.07 indicating an average range of quality level. Conclusion: The Korean version of the ONHQ was identified as a tool with a high degree of validity and reliability. This tool can be effectively used to assess the quality of nursing homes by professions as well as family members.

A Wide-range Tunable Wavelength-stabilization Technique for Semiconductor Lasers

  • Chen, Han;Qiao, Qinliang;Min, Jing;He, Cong;Zhang, Yuanyuan
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.384-390
    • /
    • 2021
  • This paper presents a wide-range tunable wavelength-locking technology based on optoelectronic oscillation (OEO) loops for optical fiber sensors and microwave photonics applications, explains the theoretical fundamentals of the design, and demonstrates a method for locking the relative wavelength differences between a leader semiconductor laser and its follower lasers. The input of the OEO loop in the proposed scheme (the relative wavelength difference) determines the radio-frequency (RF) signal frequency of the oscillation output, which is quantized into an injection current signal for feedback to control the wavelength drift of follower lasers so that they follow the wavelength change of the leader laser. The results from a 10-hour continuous experiment in a field environment show that the wavelength-locking accuracy reached ±0.38 GHz with an Allan deviation of 6.1 pm over 2 hours, and the wavelength jitter between the leader and follower lasers was suppressed within 0.01 nm, even though the test equipment was not isolated from vibrations and the temperature was not controlled. Moreover, the tunable range of wavelength locking was maintained from 10 to 17 nm for nonideal electrical devices with limited bandwidth.

Systematization Design of Linear Motor by CAE (CAE에 의한 Linear Motor의 계열화 설계)

  • 조경재;오금곤;이권현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.827-831
    • /
    • 1996
  • In this work, we propose the algorithm of similarities and design parameters by which can have a design model cmploying the analogical inference analogy. The physical characteristics for the instrument model forms the foundation of the proposed method and are brought to researchers and designers which build the systematizatio design using a computer.

  • PDF

Optical Design and Optimization of a Micro Zoom System with Liquid Lenses

  • Zhang, Wei;Li, Dan;Guo, Xin
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.447-453
    • /
    • 2013
  • A micro zoom system without moving elements by use of two liquid lenses is designed and optimized in this paper. The zoom equations of the system composed of two liquid lenses are deduced. The structure parameters including radius and thickness of a conical double-liquid electrowetting based lens are analyzed and calculated. Because the liquid thickness varies non-linearly with the radius of the interface, it's very difficult to optimize a real liquid lens using commercial optical design software directly. Through the Application Programming Interface (API) of the optical design software CODE V, a zoom system with two real electrowetting based liquid lenses is modeled and optimized. A two-liquid-lens zoom system without moving elements, with a zoom factor of 1.8 and a compact structure of 10 mm is designed for illustration. This can be useful for the camera design of mobile phones, tablets and so on. And this paper presents a convenient way of designing and optimizing a zoom system including liquid lenses by commercial optical design software.

Developemtn of the external fixator for a bone fracture (골절치료용 체외고정기기 개발을 위한 연구)

  • 윤희열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.310-315
    • /
    • 2000
  • In this paper, the problems of the external fixator that have developed for a distal radius fracture so far are analyzed, and accordingly, the characterizations, which must have a prototype, are arranged. C-Arm is used. This instrument makes it possible for the real play of the internal body by x-ray permeability. From this data, it is possible to induce important design factors. Finally, a basic mechanism, which has to be applied, is decided, and the Solid Edge program, which used a 3-D design tool, completes then total instrument design.

  • PDF

Flight Performance of a Dual One-Way Carrier Phase Ranging Instrument (이중단방향 반송파 거리측정기 비행성능 분석)

  • Kim, Jeong-Rae
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.1
    • /
    • pp.52-57
    • /
    • 2009
  • One of the error sources for microwave ranging is the instability of the oscillator that drives the microwave signals. Dual one-way ranging (DOWR) minimizes the oscillator effect by combining two one-way carrier phase signals from two transmitter/receiver instrument. The DOWR is first implemented in the GRACE (Gravity Recovery and Climate Experiment) satellites. Direct evaluation of the DOWR is not possible due to its extremely high accuracy. The flight performance of the GRACE DOWR is analyzed by applying several indirect methods. Comparison with the design noise level is discussed.

  • PDF

Sensitivity Analysis of the Optical System for UV-IR Space Telescope

  • Kim, Sanghyuk;Chang, Seunghyuk;Pak, Soojong;Jeong, Byeongjoon;Kim, Geon Hee;Hammar, Arvid
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.56.4-57
    • /
    • 2015
  • We present the optical design and a sensitivity analysis for a wide field of view (FOV) instrument operating at UV and IR wavelengths. The ongoing investigation is performed in collaboration with Omnisys Instruments (Sweden) and focuses on a telluric-limb-viewing instrument that will fly in a low Earth orbit to study mesospheric wave structures over a wide range of horizontal scales in the altitude range 80 - 100 km. The instrument has six wavelength channels which consist of 4 channels of IR and 2 of UV. We are proposing an optical design based on three mirror aplanatic off-axis reflective system. The entrance pupil diameter and effective focal length are 45 mm and 270 mm, respectively. The FOV is $5.5^{\circ}{\times}1^{\circ}$ and the secondary mirror is set for stop. The optical specification is required to have an encircled energy of at least 80 % within a diameter of 21 um. We performed sensitivity analysis for the longest wavelength of 772 nm in consideration of the diffraction limit of system. The results show that tolerance limits for positions and angles of the mirrors are not very sensitive compared with typical error budgets of manufacturing and assembling process. The secondary mirror has the most sensitive tolerance for surface figure of 250 nm in root-mean-square.

  • PDF

Computation of Ease-Rate in Basic Bodice Pattern by Analysis of Multiple Cross Section, Using 3-D Measuring Instrument (착의 단면 중합도 분석에 의한 길 원형의 여유률 산출 - 3차원 형상 계측기에 의한 -)

  • Shim, Kue-Nam;Kim, Jin-Sun;Lee, Womn-Ja
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.360-365
    • /
    • 2000
  • This research is the trial for the computation of the ease-rate for the bodice pattern. The result of the analysis about the cross section figures of garment space by using a 3-D measuring instrument is that: The garment space of each bodice by each body size is definite. In the figure of cross section of the basic lines, an area of cross section of garment space and length of cross section of garment space are not increased in proportion to an area of cross section of the body. The ease rate is the same no matter that flat-rate of the body is same or different. The ease-rate is computed by length of cross section of garment space that is in proportion to the radius of the body.

  • PDF