• Title/Summary/Keyword: instantaneous reactive power theory

Search Result 32, Processing Time 0.025 seconds

Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher (제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation (순시무효전력 보상에 의한 중성선 전류의 제거)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

A Study on the Decoupled Control of the Active and Reactive Power using Instantaneous Power Control Theory (순시전력 제어 이론을 이용한 유/무효전력의 독립제어에 관한 연구)

  • Kim, Eung-Sang;Kim, Ji-Won;Kim, Yeong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.678-682
    • /
    • 1999
  • In this paper, we propose the algorithm which can control active power and reactive power independently in Battery Energy Storage System. The proposed algorithm is based on the instantaneous power theory that the inner product of the voltage vector and current vector represents the active power and the cross product of those represents the reactive power, and it can control active power and reactive power independently. To verify the validity of the proposed algorithm, we make model of the real power system in th KERI and simulate this algorithm. As a result of this simulation, we verified that the proposed algorithm can control active power and reactive power independently.

  • PDF

The Generalized Instantaneous Power Theory Using Mapping Matrices (맵핑 매트릭스를 사용한 일반화 순시전력 이론)

  • Kim, Hyo-Sung;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1930-1932
    • /
    • 1997
  • Instantaneous active/reactive powers are defined in three phase four wire systems. The definition can be generally applicable to any source conditions and load conditions including nonlinear circuits. The zero-sequence power resulted from the zero-sequence voltage and zero-sequence current between two sub-systems affects both to the instantaneous active and reactive powers. The zero-sequence current can be controlled by compensation of the reactive power without power storage elements.

  • PDF

Eliminating the Neutral Current by the Power Compensator without using Energy Storage Elements (에너지저장요소를 사용하지 않는 전력보상기에 의한 중성선 전류의 제거)

  • Kim, Hyo-Seong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.330-335
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers qq, qr were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storge element.

  • PDF

A study on the Reactive Power Compensation using Instantaneous Power for Self Commutated Static Var Compensator (순시전력을 이용한 자려식 SVC의 무효전력보상에 관한 연구)

  • Eum, Sang-O;Kim, Jong-Yun;Jeon, Nae-Suck;Park, Chan-Kun;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1206-1208
    • /
    • 2000
  • The Static var compensators(SVC) are intensively studied to realize high performance power equipment for electric power systems. Rapid and continuous reactive compensation by the SVC contributes to voltage stabilization, power oscillation damping, overvoltage suppression, minimization of transmission losses and so on. In this paper, instantaneous power vector theory which can expresses the instantaneous apparent power vector is proposed to control reactive power. The validity of the proposed method is confirmed by simulation studies.

  • PDF

Three-Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory (순시 무효전력 이론 기반의 능동전력필터 기능을 가지는 삼상 지-소스 정류기)

  • ANVAR, IBADULLAEV;Hong, Seung-Pyo;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.365-366
    • /
    • 2015
  • Shunt active power filter is a complete current source which can provide an effective and adjustable solution for elimination of harmonic currents in power system. Its performance depends on strategy employed in reference current generation, control technique and topology of converter used in the design.[1-2]. In this paper Three Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory is described. Thanking to the theory power factor and THD value are significantly improved. Experiment results and conclusions are presented.

  • PDF

A New Scheme for Compensation of Unwanted Components of Instantaneous Load Power

  • Wong, Man-Chung;Han, Ying-Duo;Leong, Heng-San;Sio, Hon-Pan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.888-893
    • /
    • 1998
  • In practice, not only the load current but also the load voltage may contain asymmetric and harmonic components. Instantaneous power using p-q theory is analyzed to have compensation of reactive power, harmonics and asymmetry at the same time. In this paper, the limitation of p-q theory by using only shunt or series active filter is analyzed. A new scheme is proposed to solve the above issues.

  • PDF

A Design and Simulation of Hybrid Power Filter for ASD Loads Based on Instantaneous Power Compensation Theory (가변 속도 드라이버 부하에 대한 순시 전력 보상을 이용한 복합형 전력 필터의 설계와 시뮬레이션)

  • 조진호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.385-390
    • /
    • 2000
  • This paper deals with the design and simulation of the hybrid power filter to compensate reactive power and harmonic components of nonlinear load. Control target is a 3-phase diode full bridge rectifier with L-R-C nonlinear load, this load is assumed adjustable speed driver(ASD). The hybrid filter consists of a shunt active filter, shunt passive filters and series inductors. Control algorithm is based on instantaneous power compensation theory proposed by H.Akagi and etc. The result from simulation shows the hybrid filter is superior than other filters on the point of compensation performance and low cost. The PSCAD/EMTDC 3.0 is used as simulation tools.

  • PDF