• Title/Summary/Keyword: instantaneous phase

Search Result 328, Processing Time 0.026 seconds

맵핑 매트릭스를 사용한 일반화 순시전력 이론 (The Generalized Instantaneous Power Theory Using Mapping Matrices)

  • 김효성;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.1930-1932
    • /
    • 1997
  • Instantaneous active/reactive powers are defined in three phase four wire systems. The definition can be generally applicable to any source conditions and load conditions including nonlinear circuits. The zero-sequence power resulted from the zero-sequence voltage and zero-sequence current between two sub-systems affects both to the instantaneous active and reactive powers. The zero-sequence current can be controlled by compensation of the reactive power without power storage elements.

  • PDF

신경망을 이용한 디지털 변조방식의 자동식별 (Automatic Identification of Digital Modulation Methode Using an Artification Neural Network)

  • 신용조
    • 한국통신학회논문지
    • /
    • 제25권10B호
    • /
    • pp.1769-1776
    • /
    • 2000
  • In this paper a new method is proposed to identify a modulation method in the case of unknown digitally modulated input signals. The proposed identification method is implemented with an artificial neural network which is based on characteristic feature extracted from the instantaneous amplitude the instantaneous phase and the instantaneous frequency of the input signals. The proposed method was simulated with 9 type signals (ASK2, FSK2, FSK4, PSK2, PSK4, PSK8, QAM8, QAM16) in a noisy communication environment. The results show that the artificial neural network can accurately recognize all kinds of patterns.

  • PDF

순시전압강하 보상기의 새로운 제어 기법 (A New Control Algorithm for Instantaneous Voltage Sag Corrector)

  • 이상훈;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF

Voltage Sag Detection Algorithm for Instantaneous Voltage Sag Corrector

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.162-170
    • /
    • 2002
  • Voltage sag detection algorithm for voltage sag corrector is proposed in this paper. To quantify the standard of voltage unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (UF). It is analyzed that MWF and UF values are given as the dc constant values even though under the voltage unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

적응 역기전력 추정기와 개선된 순시 무효전력 보상기를 이용한 돌극형 영구자석 전동기의 센서리스 제어 (A Sensorless Control of IPMSM using the Adaptive Back-EMF Estimator and Improved Instantaneous Reactive Power Compensator)

  • 이준민;홍주훈;김영석
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.794-803
    • /
    • 2016
  • This paper propose a sensorless control system of IPMSM with a adaptive back-EMF estimator and improved instantaneous reactive power compensator. A saliency-based back-EMF is estimated by using the adaptive algorithm. The estimated back-EMF is inputted to the phase locked loop(PLL) and the improved instantaneous reactive power(IRP) compensator for estimating the position/speed of the rotor and compensating the error components between the estimated and the actual position, respectively. The stability of the proposed system is achieved through Popov's hyper stability criteria. The validity of proposed algorithm is verified by the simulations and experiments.

An Active Auxiliary Quasi-Resonant Commutation Block Snubber-Assisted Three Phase Voltage Source Soft Switching PFC Rectifier using IGBTs

  • Hiraki Eiji;Nakaoka Mutsuo;Sugimoto Shigeyuki;Ogawa Shigeaki
    • Journal of Power Electronics
    • /
    • 제5권1호
    • /
    • pp.29-35
    • /
    • 2005
  • This paper presents a novel prototype of an active auxiliary quasi-resonant snubber(Auxiliary Quasi-Resonant Commutation Block-Link; ARCB)-assisted three phase voltage source soft switching space voltage vector modulated PFC rectifier, which uses Zero Voltage Soft Switching (ZVS) commutation. The operating principles of this digitally-controlled three phase soft switching PWM-PFC rectifier system with an instantaneous power feedback scheme are illustrated and its steady-state performance is evaluated using computer-aided simulation analysis.

회전좌표계를 이용한 단상능동전력필터의 제어이론 (A Control Algorithm of Single Phase Active Power Filter based on Rotating Reference Frame)

  • 김진선;김영석;신재화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1480-1482
    • /
    • 2005
  • The major causes of power quality deterioration are harmonic current through semiconductor switching device, due to use of nonlinear loads such as diodes rectifier or thyristor rectifiers. In response to this concerns, this paper presents a new control method of single-phase active power filter(APF) for the compensation of harmonic current components in nonlinear loads. In order to make the complex calculation to be possible, the single-phase system that has two phases was made by constructing a imaginary second-phase giving time delay to load currents. In the conventional method, a imaginary-phase lagged to the load current T/4(here T is the fundamental cycle) was made. But in this proposed method, the new signal, which has the delayed phase through the filter, using the phase-delay property of low-pass filter, was used as the second phase. As this control method is applied to the system of single phase, an instantaneous calculation was done rather by using the rotating reference frames that synchronizes with source-frequency than by applying instantaneous reactive power theory that uses the conventional fixed reference frames.

  • PDF

DFT 알고리즘을 이용한 PLL의 순시 추종 (The Instantaneous Phase-Tracking in PLL using the DFT Algorithm)

  • 김윤서;양오
    • 전자공학회논문지SC
    • /
    • 제45권6호
    • /
    • pp.141-148
    • /
    • 2008
  • 신재생 에너지 분야에서 각광받고 있는 계통 연계형 태양광 인버터에서는 계통과의 연계를 위해서 반드시 계통의 위상 정보가 필요하다. 본 논문에서는 계통 연계형 태양광 발전 시스템에서의 위상 동기화 방법으로 원하는 기준 신호의 주파수를 구하여 동기신호로 사용하고, DFT(Discrete Fourier Transform) 알고리즘을 이용하여 기준 신호와의 위상차를 구하여 위상차만큼 보상하는 PLL(Phase Locked Loop)의 순시 추종방법을 제안하였다. 또한 DFT 연산에 사용되는 한주기 값들을 샘플링 할때마다 보정 위상 값을 구하는 방법과 특정 주파수의 기준신호에 대한 주파수 및 위상 추종뿐만 아니라 다양한 주파수 신호에 대한 주파수 및 위상을 추종하는 방법을 적용하여 시뮬레이션과 실험을 통해 본 논문의 타당성을 검증하여 유효성을 보이고자 한다.

Power Module Bridge Type Auxiliary Resonant AC Link Snubber-Assisted Three-Phase Soft Switching Inverter

  • Hisashi Iyomori;Nagai, Shin-ichiro;Masanobu Yoshida;Eiji Hiraki;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.77-86
    • /
    • 2004
  • This paper presents a novel three-phase power module bridge type auxiliary resonant AC link snubber for the three-phase voltage-fed sinwave soft switching PWM inverter operating under specific instantaneous space voltage vector modulation. The operating principle of this resonant snubber is described for current source load model during one switching period, along with its design approach based on the simulation data. The performance evaluations of space vector modulation three-phase sinewave soft switching inverter with a new three-phase active auxiliary resonant AC link snubber are discussed as compared with those of three-phase voltage source-fed sinewave hard switching PWM inverter with a standard space voltage vector modulation strategy. The power loss analysis and conventional efficiency estimation of three-phase soft switching PWM inverter using ICBT modules are carried out including all the conduction power losses based upon the measured v-i characteristics of IGBT and its antiparallel diode as well as their switching losses.