• 제목/요약/키워드: instantaneous phase

검색결과 328건 처리시간 0.03초

A Study of Ice-Formation Phenomena on Freezing of Flowing Water in a Stenotic Tube

  • Suh, Jeong-Se;Kim, Moo-Geun;Ro, Sung-Tack;Yim, Chang-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.1-10
    • /
    • 1999
  • In this study, a numerical analysis is made on the ice-formation for laminar water flow inside a stenotic tube. The study takes into account the interaction between the laminar flow and the stenotic port in the circular tube. The purpose of the present numerical investigation is to assess the effect of a stenotic shape on the instantaneous shape of the flow passage during freezing upstream/downstream of the stenotic channel. In the solution strategy, the present study is substantially distinguished from the existing works in that the complete set of governing equations in both the solid and liquid regions are resolved. In a channel flow between parallel plates, the agreement between the of predictions and the available experimental data is very good. Numerical analyses are performed for parametric variations of the position and heights of stenotic shape and flow rate. The results show that the stenotic shape has the great effect on the thickness of the solidification layer inside the tube. As the height of a stenosis grows and the length of a stenosis decreases, the ice layer thickness near the stenotic port is thinner, due to backward flow caused by the sudden expansion of a water tunnel. It is found that the flow passage has a slight uniform taper up to the stenotic channel, at which a sudden expansion is observed. It is also shown that the ice layer becomes more fat in accordance with its Reynolds number.

  • PDF

터빈형과 기어모터형 유량계의 동특성 검토 (An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters)

  • 예용택
    • 한국생산제조학회지
    • /
    • 제9권3호
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

Atomization Characteristics in Pneumatic Counterflowing Internal Mixing Nozzle

  • Lee, Sam-Goo;Rho, Byung-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제14권10호
    • /
    • pp.1131-1142
    • /
    • 2000
  • In an effort to illustrate the global variation of SMD (Sauter mean diameter, or $D_{32}$) and AMD (Arithmetic mean diameter, or $D_{10}$) at five axial downstream locations (i. e., at Z=30, 50, 80, 120, and 170 mm) under the different experimental conditions, the radial coordinate is normalized by the spray half-width. Experimental data to analyze the atomization characteristics concerning with an internal mixing type have been obtained using a PDPA(Phase Doppler Particle Analyzer). The air injection pressure was varied from 40 kPa to 120 kPa. In this study, counterflowing internal mixing nozzles manufactured at an angle of $15^{\circ}$with axi-symmetric tangential-drilled four holes have been considered. By comparing the results, it is clearly possible to discern the effects of increasing air pressure, suggesting that the disintegration process is enhanced and finer spray droplets can be obtained under higher air assist. The variations in $D_{32}$ are attributed to the characteristic feature of internal mixing nozzle in which the droplets are preferentially ejected downward with strong axial momentum, and dispersed with the larger droplets which are detected in the spray centerline at the near stations and smaller ones are generated due to further subsequent breakup by higher shear stresses at farther axial locations. The poor atomization around the centre close to the nozzle exit is attributed to the fact that the relatively lower rates of spherical particles are detected and these drops are not subject to instantaneous breakup in spite of the strong axial momentum. However, substantial increases in SMD from the central part toward the edge of the spray as they go farther downstream are mainly due to the fact that the relative velocity of droplet is too low to cause any subsequent disintegration.

  • PDF

캐비테이션 터널에서 PIV를 이용한 프로펠러 후류 보오텍스 유동계측 및 거동해석 (PIV Aanalysis of Vortical Flow behind a Rotating Propeller in a Cavitation Tunnel)

  • 백부근;김진;박영하;김기섭;김경열
    • 대한조선학회논문집
    • /
    • 제42권6호
    • /
    • pp.619-630
    • /
    • 2005
  • A two-frame PIV (Particle Image Velocimetry) technique is used to investigate the wake characteristics behind a marine propeller with 4 blades at high Reynolds number. For each of 9 different blade phases from $ 0^{\circ} $ to $ 80^{\circ} $, one hundred and fifty instantaneous velocity fields are measured. They are ensemble averaged to study the spatial evolution of the propeller wake in the region ranging from the trailing edge to one propeller diameter (D) downstream location. The phase-averaged mean velocity shows that the trailing vorticity is related to radial velocity jump, and the viscous wake is affected by boundary layers developed on the blade surfaces and centrifugal force. Both Galilean decomposition method and vortex identification method using swirling strength calculation are very useful for the study of vortex behaviors En the propeller wake legion. The slipstream contraction occurs in the near-wake region up to about X/D : 0.53 downstream. Thereafter, unstable oscillation occurs because of the reduction of interaction between the tip vortex and the wake sheet behind the maximum contraction point.

Characteristics of the Atomization in Counter-Swirl Internal Mixing Atomizer

  • Lee, Sam-Goo;Kim, Kyu-Chul;Park, Byung-Joon
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1999년도 제13회 학술강연논문집
    • /
    • pp.27-27
    • /
    • 1999
  • To illustrate the global variation of the droplet mean diameters and the turbulent flow characteristics in counterflowing internal mixing pneumatic nozzle, the experimental measurements at five axial downstream locations(i.e., at Z=30, 50, 80, 120, and 170mm) were made using a PDPA(Phase Doppler Particle Analyzer) under the different air injection pressures ranging from 40 ㎪ to 120 ㎪. A nozzle with axi-symmetric tangential-drilled four holes at an angle of 15$^{\circ}$ has been designed and manufactured. The distributions of velocities, turbulence intensities, turbulence kinetic energy, turbulent correlation coefficients, spray angle, droplet mean diameters, volume flux, number density are quantitatively analyzed. It is possible to discern the effects of increasing air pressure. It indicates that the strong axial momentum in spite of more or less disparity between the velocity components means more reluctant to disperse radially, and that axial fluctuating velocities are substantially higher than those of radial and tangential ones, suggesting that the disintegration process is enhanced under higher air assist. The larger droplets are detected in the spray centerline at the near stations and smaller ones are generated due to further subsequent breakup at farther axial locations are attributed to the internal mixing type nozzle characteristics. Despite of the strong axial momentum, the poor atomization around the centre close to the nozzle exit is attributed to the lower rates of spherical particles which are not subject to instantaneous breakup. As it goes downstream, however, substantial increases in SMD(Sauter Mean Diameter) from the central part toward spray periphery are understandable because the droplet relative velocity is too low to bring about any subsequent disintegration.

  • PDF

국내 저압 전기기기의 고조파 유출 제한값 산정 (Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment)

  • 강문호;송양회;이흥호
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.56-61
    • /
    • 2008
  • 배전계통의 고조파 방해(Harmonics Disturbance)현상은 배전계통에서 전압강하와 함께 순시 전력품질을 저해하여 중성선 및 NGR(Neutral Ground Reactor) 과열, OCGR 오동작 등의 문제를 발생시킴으로써 전력회사와 고객 모두에게 막대한 경제적인 손실을 주고 있어 동 분야에 대한 적극적인 대책이 필요하다. 이에 대한 해결 방안으로 유럽에서는 IEC 61000-3-2 규격을 통해 상당 16[A] 이하 저압 전기기기의 고조파를 제한하고 있다. 본 규격은 저압 전기기기를 4개의 등급으로 구분하여 관리하고 있으며, 분석결과 클래스 A등급 해당 전기기기의 고조파 유출제한 기준은 저압계통의 기준임피던스와 허용 최대전압을 바탕으로 산정되었으며, 타 등급(B, C, D등급)의 유출제한 기준들도 클래스 A의 유출제한 기준을 바탕으로 산정되었다. 따라서 본 논문에서는 IEC 61000-3-2 규격 분석결과를 바탕으로 국내 기준임피던스에 기초하여 국내 저압 전기기기의 고조파 유출 제한 값을 산정하였다.

심해 풍파 아래에서의 응집 구조 (Coherent Structures beneath Wind-Generated Deepwater Waves)

  • 오상호;서경덕
    • 한국해안해양공학회지
    • /
    • 제19권1호
    • /
    • pp.16-28
    • /
    • 2007
  • 이 연구에서는 심해 풍파 아래에서의 응집구조(coherent structures)에 대한 실험실 실험 결과를 제시하였다. 풍속과 취송거리가 서로 다른 실험 조건에서 입자화상유속계를 이용하여 취득된 심해 풍파의 속도장으로부터 와도장을 가시화하고 응집구조가 시 공간적으로 변천하는 양상 및 그에 따른 와도의 연직 분포 변화를 정성적으로 분석하였다. 파봉 아래에서는 파와 같은 위상으로 함께 진행하는 응집구조가 존재함을 확인하였다. 이 응집구조의 회전 방향은 바람이 10 m/s 이하인 실험 조건에서는 파 내부의 입자 궤도 운동과 반대 방향인 반면, 바람의 세기가 약 13 m/s이고 파봉 근처에서 쇄파가 발생하는 경우에는 같은 방향이었다. 수면 근처에서는 응집구조의 진행에 따른 복잡한 소용돌이 상호 작용이 나타나는 반면, 수면으로부터 깊은 수심에서는 파 궤도 운동의 영향이 미미하여 응집구조의 시 공간적 변화가 거의 없었다.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

4채널 지연선로를 이용한 디지털 주파수 판별기 구현에 관한 연구 (Study on Implementation of a Digital Frequency Discriminator using 4 channel Delay line)

  • 국찬호;권익진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.512-515
    • /
    • 2010
  • 공간상에 존재하는 전자파를 측정, 분석하여 신호정보(SIGINT; SIGnal INTelligence)를 획득하기 위해서 가장 중요한 것이 전자파의 주파수 정보이다. 특히 레이다 및 미사일에서 방사되는 초고주파 대역의 주파수를 순시 측정하는 방법으로, 지연선로의 위상차를 측정하여 주파수정보를 디지털데이터를 출력하는 부품으로 디지털 주파수 판별기(Digital frequency Discriminator; DFD)가 있다. DFD는 100nSec 이하의 짧은 시간동안에 존재하는 고주파 신호에 대해서도 초고주파신호의 주파수 정보를 실시간으로 측정하여 제공해야 한다. 본 논문에서는 광대역 4 채널의 지연선로와 코릴레이터로 구성된 고주파 입력부와 I/Q신호를 처리하여 주파수 정보를 얻어내는 디지털 처리부 및 정확한 주파수 정보를 얻기 위한 주파수 보정부로 이루어진 DFD의 구현방안을 제안하고 아주 짧은 펄스 형태의 모의 레이다 신호를 입력하여 얻은 시험결과를 토대로 설계의 타당성을 확인한다.

  • PDF

An Enhanced Instantaneous Circulating Current Control for Reactive Power and Harmonic Load Sharing in Islanded Microgrids

  • Lorzadeh, Iman;Abyaneh, Hossein Askarian;Savaghebi, Mehdi;Lorzadeh, Omid;Bakhshai, Alireza;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1658-1671
    • /
    • 2017
  • To address the inaccurate load demand sharing problems among parallel inverter-interfaced voltage-controlled distributed generation (DG) units in islanded microgrids (MGs) with different DG power ratings and mismatched feeder impedances, an enhanced voltage control scheme based on the active compensation of circulating voltage drops is proposed in this paper. Using the proposed strategy, reactive power and harmonic currents are shared accurately and proportionally without knowledge of the feeder impedances. Since the proposed local controller consists of two well-separated fundamental and harmonic voltage control branches, the reactive power and harmonic currents can be independently shared without having a remarkable effect on the amplitude or quality of the DGs voltage, even if nonlinear (harmonic) loads are directly connected at the output terminals of the units. In addition, accurate load sharing can also be attained when the plug-and-play performance of DGs and various loading conditions are applied to MGs. The effects of communication failures and latency on the performance of the proposed strategy are also explored. The design process of the proposed control system is presented in detail and comprehensive simulation studies on a three-phase MG are provided to validate the effectiveness of the proposed control method.