• Title/Summary/Keyword: instantaneous parameters

Search Result 221, Processing Time 0.032 seconds

Rainfall-Runoff Analysis by Calculation of the Time Distribution Models for Storms (降雨의 時間 分布模型 算定에 의한 降雨-流出 解析)

  • 민경형;이영대
    • Water for future
    • /
    • v.29 no.6
    • /
    • pp.189-201
    • /
    • 1996
  • The main objective of this study is to determine the time distribution models of rainfall in Korea for estimating design floods and to suggest new runoff model(Geomorphologic Instantaneous Unit Hydrograph; GIUH) in order to be easily use the rainfall-runoff model put rainfall models practice to be suitable for the regional characteristics of hydrologic situation by practicing engineers. As a result, the reappearance of triangular hyetograph and GIUH runoff model showed promising. The historical data from about 13,000 event-rainfalls and 73 rainfall-runoff measuring data during 12 years in International Hydrological Program (IHP) basins have been used to determine the statistical factors of the time distribution for rainfalls by the Yen-Chow, Huff, Pilgrim-Cordery and Mononobe models. The Rational, Kajiyama, Nakayasu and Clark model and GIUH model that this study runoff model were used for the purpose of application limit for basin area against design concept by the estimation of flood runoff and the derivation of empirical equations to estimate the parameters for ungaged basins.

  • PDF

An Experimental Study on the Injector-spray Behavior of a Liquid-propellant Thruster (액체추진제 추력기의 인젝터 분무 거동에 대한 실험적 연구)

  • Kim, Jin-Seok;Kim, Sung-Cho;Park, Jeong;Kim, Jeong-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.9
    • /
    • pp.799-804
    • /
    • 2007
  • The behavior of spray emanating from an injector to be employed in a liquid-propellant thrust chamber is investigated by optical measurement techniques. The injector has eight holes, each of which has 30 cant angle from the center-axis with the diameter of 0.406 mm. In order to examine an atomization process according to the spray-generation conditions and the evolution along spray downstream, variational features in the velocity and size of droplets obtained through Dual-mode Phase Doppler An 799emometry (DPDA) are delineated and discussed together with instantaneous plane images captured by using Nd:Yag laser sheet beam. A categorization of spray-flow regime representing the atomization and turbulent nature is made through evaluating the non-dimensional parameters, i.e., Reynolds number and Weber number based upon the theoretical injection velocity. These qualitative and quantitative data of spray breakup will be a firm basis for the design of brand-new thruster

A Study on the Geomorphologic Synthesis of Hydrologic Response (수문응답의 지형학적 합성방법에 관한 연구)

  • Cho, Hong Je;Lee, Sang Bae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.99-108
    • /
    • 1990
  • A Synthetic Unit Hydrograph Method was investigated for representation of the effective rainfall-direct runoff hydrograph by using a Geomorphologic Instantaneous Unit Hydrograpb(GIUH) proposed by Gupta et al(1980). The response function of the basin was assumed to be the two-parameter gamma probability density function. The physical parameters of the response function(Nash Model) was determined by using the regression eqs. were parameterized in terms of Horton order ratios and the relations between the basin lag time and time-scale parameter. The capability of the Synthetic Unit Hydrograph to the real basin was tested for the Pyungchang river basin and Wi Stream basin, and its capability to reproduce the hydrologic response was investigate and compared with the Moment Method and the Least Square Method used incomplete gamma function. The representation of the peak flow, the time to peak and the hydrographs the derived Synthetic Unit Hydrograph were tested on some obseved flood data and showed promising, and it was approved to be used for prediction of the ungaged basins.

  • PDF

Wall Superheat Effect on Single Bubble Growth During Nucleate Boiling at Saturated Pool (풀 핵비등시 단일 기포 성장에 대한 벽면 과열도의 영향에 관한 연구)

  • Kim Jeong bae;Lee Han Choon;Kim Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.633-642
    • /
    • 2005
  • Nucleate pool boiling experiments for R11 under a constant wall temperature condition were carried out. A microscale heater array was used for the heating and the measurement of high temporal and spatial resolution by the Wheatstone bridge circuit. Very sensitive heat flow rate data were obtained by the control for the surface condition with high time resolution. The measured heat flow rate shows a discernable peak at the initial growth stage and reaches an almost constant value. In the thermal growth region, bubble shows a growth proportional to $t^{\frac{1}{5}}$. The bubble growth behavior is analyzed with a dimensionless parameter to compare with the previous results in the same scale. As the wall superheat increases, the departure diameter and the departure time increase, and the waiting time decreases. But the asymptotic growth rate is not affected by the wall superheat change. The effect of the wall superheat is resolved into the suggested growth equation. Dimensionless parameters of time and bubble radius characterize the thermal growth behavior well, irrespective of wall condition. The comparison between the result of this study and the previous results shows a good agreement at the thermal growth region. The quantitative analysis for the heat transfer mechanism is conducted with the measured heat flow rate behavior and the bubble growth behavior. The required heat flow rate for the volume change of the observed bubble is about twice as much as the instantaneous heat flow rate supplied from the wall.

Stock Assessment of the Southern Bluefin Tuna Thunnus maccoyii Using the MULTIFAN-CL Model (MULTIFAN-CL 모델을 이용한 남방참다랑어 Thunnus maccoyii의 자원 평가)

  • Kwon, You-Jung;Moon, Dae-Yeon;Zhang, Chang-Ik;Koh, Jeong-Rack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.40 no.6
    • /
    • pp.367-373
    • /
    • 2007
  • We assessed the stock of the southern bluefin tuna (SBT, Thunnus maccoyii) by applying the MULTIFAN-CL model. The model is spatially disaggregated, with the population and fisheries stratified into a number of regions within the overall stock range. Catch, effort, length-frequency, and tagging data from 1965 to 2003 were stratified by three regions and four quarters (Jan-Mar, Apr-Jun, Jul-Sept and Oct-Dec). These data were used to estimate the instantaneous fishing mortality (F), biomass, spawning biomass, recruitment, and so on. The Commission for the Conservation of Southern Bluefin Tuna (CCSBT) used only Japanese data and did not consider migration for the SBT stock assessment. By contrast, we used Japanese, Australian, New Zealand, Taiwanese, and Korean data, and considered migration. As a result, the estimated annual average F of all age classes was 0.073/yr and the F of age class 6-10 was the highest. The results also showed that the biomass and recruitment of SBT had declined significantly after 1965. Compared with the CCSBT results, the estimated spawning biomass in this study was lower and more uncertain. However, we will conduct a sensitivity analysis to get more accurate biological parameters and results. In addition, we need to use the bootstrap resampling method to quantify the uncertainty.

Changes of the Flame Temperature and OH Radical in the Unsteady Extinction Process (비정상 소화 과정에서의 화염 온도 및 OH 라디칼의 변화)

  • Lee, Uen-Do;Lee, Ki-Ho;Oh, Kwang-Chul;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1557-1566
    • /
    • 2004
  • A flame extinction phenomenon is a typical unsteady process in combustion. Flame extinction is characterized by various physical phenomena, such as convection, diffusion, and the production of heat and mass. Flame extinction can be achieved by either increasing the strain rate or curvature, by diluting an inert gas or inhibitor, or by increasing the thermal or radiant energy loss. Though the extinction is an inherently transient process, steady and quasi-steady approaches have been used as useful tools for understanding the flame extinction phenomenon. Recently, unsteady characteristics of flames have been studied by many researchers, and various attempts have been made to understand unsteady flame behavior, by using various extinction processes. Representative parameters for describing flame, such as flame temperature, important species related to reactions, and chemi-luminescence of the flame have been used as criterions of flame extinction. In these works, verification of each parameter and establishing the proper criterions of the extinction has been very important. In this study, a time-dependent flame temperature and an OH radical concentration were measured using optical methods, and the instantaneous change of the flame luminosity was also measured using a high-speed ICCD (HICCD) camera. We compare the unsteady extinction points obtained by three different methods, and we discuss transient characteristics of maximum flame temperature and OH radical distribution near the extinction limit.

Flow Control Inside a Molten Zn Pot for Improving Surface Quality of Zinc Plated Strips (아연도금강판의 품질향상을 위한 도금욕 내부 유동제어 연구)

  • Choi, Jae-Ho;Koh, Min-Seok;Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1392-1399
    • /
    • 2001
  • The flow fields inside a molten Zn pot of continuous hot-chip galvanizing process were investigated experimentally. With varying several parameters including the strip speed Vs, flow rate Q of induction heater. scrapper location and baffle configuration, instantaneous velocity fields were measured using a PIV velocity field measurement technique. Inside the strip region, counter-clockwise rotating flow is dominant. The general flow pattern inside the strip region is nearly not influenced by the strip speed Vs, flow rate Q and the scrapper location. In the exit region, the flow separated from the moving strip due to the existence of a stabilizing roll ascends to the free surface, for the cases of no scrapper and scrapper detached form the roll. On the other hand, the ascending flow to the free surface is decreased, as the flow rate Q of induction heater increases. By installing a baffle around the uprising strip, the flow moving up to the stabilizing roll decreases. In addition, B-type baffle is better than A-type baffle in reducing speed of flow around the stabilizing rolls. However, the flow ascended to the free surface is largely influenced by changing the flow rate Q, and the scrapper location, irrespective of the baffle type.

The assessment of the relative contribution of the shape of instantaneous unit hydrograph with heterogeneity of drainage path (배수경로 이질성에 의한 순간단위도 형상의 상대적 기여도 평가)

  • Choi, Yong-Joon;Kim, Joo-Cheol;Kim, Jae-Han
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.11
    • /
    • pp.897-909
    • /
    • 2009
  • The relative contribution of between hillslope-flow and stream-flow by heterogeneity of drainage path are quantitatively assessed in the present study with GIUH model based on grid of GIS. Application watersheds are selected Pyeongchang, Bocheong and Wi river basin of IHP in Korea. The mean and variance of hillslope and stream length are estimated and analyzed in each watershed. And coupling with observation storm events, estimate hillslope and stream characteristic velocity which dynamic parameters of GIUH model. The mean and variance of distribution of travel time (i.e. IUH) calculate using estimated pass lengths and characteristic velocities. And the relative contributions are assessed by heterogeneity of drainage path. As a result, the effect of the variance that determine shape of IUH dominate with hillslope's effect in the small watershed area (within 500 $km^2$). Thus, GIUH in the small watershed area must consider hillslope-flow.

An Analysis for Goodness of Fit on Trigger Runoff of Flash Flood and Topographic Parameters Using GIS (GIS를 이용한 돌발홍수의 한계유량과 유역특성인자의 적합도 분석)

  • Oh, Myung-Jin;Yang, In-Tae;Park, Byung-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.3 s.37
    • /
    • pp.87-95
    • /
    • 2006
  • Recently, local heavy rain for a short term is caused by unusual changing in the weather. This phenomenon has, several times, caused an extensive flash flood, casualties, and material damage. This study is aimed at calculating the characteristics of flash floods in streams. For this purpose, the analysis of topographical characteristics of water basin through applying GIS techniques will be conducted. The flash flood prediction model we used is made with GCIUH (geomorphoclimatic instantaneous unit hydrograph). The database is established by the use of GIS and by the extraction of streams and watersheds from DEM. The streams studied are included small, middle and large scale watersheds. For the first, for the establishment or criteria on the flash flood warning, peak discharge and trigger runoff must be decided. This study analyzed the degree or aptitude of topographical factors to the trigger runoff calculated by GCUH model.

  • PDF

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.